Influence of beta-blocker therapy on antitachycardia pacing effectiveness for monomorphic ventricular tachycardias occurring in implantable cardioverter-defibrillator patients: a dose-dependent effect

被引:18
|
作者
Jimenez-Candil, Javier [1 ]
Hernandez, Jesus [1 ]
Martin, Ana [1 ]
Ruiz-Olgado, Maria [1 ]
Herrero, Jesus [1 ]
Ledesma, Claudio [1 ]
Morinigo, Jose [1 ]
Martin-Luengo, Candido [1 ]
机构
[1] Univ Hosp, Arrhtythmias Unit, Dept Cardiol, Salamanca 37007, Spain
来源
EUROPACE | 2010年 / 12卷 / 09期
关键词
Implantable cardioverter-defibrillator; Beta-blockers; Ventricular tachycardia; Antitachycardia pacing; Shock; MYOCARDIAL-INFARCTION; SHOCKS; SURVIVAL; EFFICACY; TRIAL;
D O I
10.1093/europace/euq164
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To determine, in a non-selected population of 282 implantable cardioverter-defibrillator (ICD) patients with left ventricular dysfunction, the influence of the dose of beta-blockers on antitachycardia pacing (ATP) effectiveness and on the incidence of shock due to monomorphic ventricular tachycardias (VT). We followed 282 ICD patients along 26 +/- 19 months. Antitachycardia pacing and shock programming were standardized. We determined the indexed dose equivalent of beta-blockers (IDE-BB), using metoprolol as a reference, at each VT presentation. The median of IDE-BB was 55 mg/m(2)/day. We analysed 846 VT occurred in 100 patients. The ATP success rate was 84%. Upon classification of the events into three groups (IDE-BB = 0, IDE-BB < 55, and IDE-BB >= 55), the frequency of effective ATP increased with the IDE-BB: 75 vs. 83 vs. 92% (P < 0.001). According to logistic regression, IDE-BB remained as an independent predictor of effective ATP (P < 0.001) and VT-related shock (P = 0.001). Both the mean ATP effectiveness per patient (67 vs. 80 vs. 91%, P = 0.007) and the mean survival time free of VT-related shock (583 vs. 847 vs. 1158 days, P = 0.019, log-rank test) increased linearly with the dose of beta-blockers. Beta-blockers increase the effectiveness of ATP through a dose-dependent effect. As a result, they reduce the incidence of shocks due to VT.
引用
收藏
页码:1231 / 1238
页数:8
相关论文
共 30 条
  • [1] Beta-Blocker Therapy and Effectiveness of Antitachycardia Pacing among ICD Patients: A Dose-Dependent Effect
    Jimenez-Candil, Javier
    Morinigo, Jose
    Olgado, Maria Ruiz
    Ledesma, Claudio
    Martin-Luengo, Candido
    CIRCULATION, 2008, 118 (18) : S672 - S672
  • [2] Beta-blocker therapy and efficacy of Antitachycardia Pacing in ICD patients: a dose-dependent effect
    Jimenez-Candil, J.
    Herrero Garibi, J.
    Morinigo, J.
    Leon, V.
    Martin, F.
    Ledesma, C.
    Martin Luengo, C.
    EUROPEAN HEART JOURNAL, 2008, 29 : 641 - 641
  • [3] Relation of Ventricular Tachycardia/Fibrillation to Beta-Blocker Dose Maximization Guided by Pacing Mode Analysis in. Nonpacemaker-Dependent Patients With Implantable Cardioverter-Defibrillator
    Deftereos, Spyridon
    Giannopoulos, Georgios
    Kossyvakis, Charalampos
    Kaoukis, Andreas
    Raisakis, Konstantinos
    Panagopoulou, Vasiliki
    Ntzouvara, Olga
    Perpinia, Anastasia
    Rentoukas, Ilias
    Pyrgakis, Vlasios
    Manolis, Antonios S.
    Stefanadis, Christodoulos
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (12): : 1812 - 1817
  • [4] Beta-blocker therapy is not associated with symptoms of depression and anxiety in patients receiving an implantable cardioverter-defibrillator
    Hoogwegt, Madelein T.
    Kupper, Nina
    Theuns, Dominic A. M. J.
    Jordaens, Luc
    Pedersen, Susanne S.
    EUROPACE, 2012, 14 (01): : 74 - 80
  • [5] Does Volume Overload Predict Failed Antitachycardia Pacing Therapy for Ventricular Tachycardia in Patients With an Implantable Cardioverter-Defibrillator?
    Hosseini-khalili, Alireza
    Kluger, Jeffrey
    CIRCULATION, 2014, 130
  • [6] Outpatient therapy with milrinone in patients with an implantable cardioverter defibrillator and a beta-blocker
    Donaho, Erin
    Shabari, Farshad R.
    Barrash, Lauren
    Poulin, Gregory V.
    Delgado, Reynolds M.
    JOURNAL OF CARDIAC FAILURE, 2008, 14 (06) : S116 - S116
  • [7] Antitachycardia pacing for spontaneous rapid ventricular tachycardia in patients with prophylactic cardioverter-defibrillator therapy
    Grimm, Wolfram
    Plachta, Eveline
    Maisch, Bernhard
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (07): : 759 - 764
  • [8] Optimizing implantable cardioverter-defibrillator treatment of rapid ventricular tachycardia: Antitachycardia pacing therapy during charging
    Schoels, Wolfgang
    Steinhaus, David
    Ben Johnson, W.
    O'Hara, Gilles
    Schwab, Joerg O.
    Jenniskens, Inge
    DeGroot, Paul J.
    Tang, Feng
    Helmling, Erhard
    HEART RHYTHM, 2007, 4 (07) : 879 - 885
  • [9] Relationship between Duration of Basal QRS Complex and Effectiveness of Antitachycardia Pacing In Implantable Cardioverter-Defibrillator Patients
    Jimenez-Candil, Javier
    Morinigo, Jose
    Olgado, Maria Ruiz
    Ledesma, Claudio
    Martin-Luengo, Candido
    CIRCULATION, 2008, 118 (18) : S673 - S673
  • [10] Implications of beta-blockers therapy dose on Antitachycardia Pacing effectiveness and shocks incidence among Monomorphic Ventricular Tachycardias occurred in ICD patients
    Jimenez-Candil, J.
    Morinigo, J.
    Martin, A.
    Ledesma, C.
    Ruiz, M.
    Martin-Luengo, C.
    EUROPEAN HEART JOURNAL, 2009, 30 : 277 - 277