Radical prostatectomy is a common treatment option for prostate cancer before it has spread beyond the prostate. Examination for surgical margins is performed post-operatively with positive margins reported to occur in 6.5-32% of cases. Rapid identification of cancerous tissue during surgery could improve surgical resection. Desorption electrospray ionization (DESI) is an ambient ionization method which produces mass spectra dominated by lipid signals directly from prostate tissue. With the use of multivariate statistics, these mass spectra can be used to differentiate cancerous and normal tissue. The method was applied to 100 samples from 12 human patients to create a training set of MS data. The quality of the discrimination achieved was evaluated using principal component analysis -linear discriminant analysis (PCA-LDA) and confirmed by histopathology. Cross validation (PCA-LDA) showed > 95% accuracy. An even faster and more convenient method, touch spray (TS) mass spectrometry, not previously tested to differentiate diseased tissue, was also evaluated by building a similar MS data base characteristic of tumor and normal tissue. An independent set of 70 non-targeted biopsies from six patients was then used to record lipid profile data resulting in 110 data points for an evaluation dataset for TS-MS. This method gave prediction success rates measured against histopathology of 93%. These results suggest that DESI and TS could be useful in differentiating tumor and normal prostate tissue at surgical margins and that these methods should be evaluated intra-operatively.
引用
收藏
页码:1090 / 1098
页数:9
相关论文
共 50 条
  • [1] Cholesterol Sulfate Imaging in Human Prostate Cancer Tissue by Desorption Electrospray Ionization Mass Spectrometry
    Eberlin, Livia S.
    Dill, Allison L.
    Costa, Anthony B.
    Ifa, Demian R.
    Cheng, Liang
    Masterson, Timothy
    Koch, Michael
    Ratliff, Timothy L.
    Cooks, R. Graham
    ANALYTICAL CHEMISTRY, 2010, 82 (09) : 3430 - 3434
  • [2] Tissue imprint imaging by desorption electrospray ionization mass spectrometry
    Ifa, Demian R.
    Srimany, Amitava
    Eberlin, Livia S.
    Naik, Hemanta R.
    Bhat, Vasudeva
    Cooks, R. Graham
    Pradeep, T.
    ANALYTICAL METHODS, 2011, 3 (08) : 1910 - 1912
  • [3] Ion suppression effect in desorption electrospray ionization and electrospray ionization mass spectrometry
    Wang, Zheng
    Zhu, Haijing
    Huang, Guangming
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2017, 31 (23) : 1957 - 1962
  • [4] Electrospray laser desorption ionization mass spectrometry
    Huang, Min-Zong
    Jhang, Siou-Sian
    Chan, Ya-Ting
    Cheng, Sy-Chi
    Cheng, Chun-Nian
    Shiea, Jentaie
    New Developments in Mass Spectrometry, 2015, 2015-January (02): : 372 - 388
  • [5] Desorption electrospray ionization ambient mass spectrometry
    Beatriz Pomilio, Alicia
    Alberto Bernatene, Eduardo
    Alberto Vitale, Arturo
    ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2011, 45 (01): : 47 - 79
  • [6] Tissue Imaging Using Nanospray Desorption Electrospray Ionization Mass Spectrometry
    Laskin, Julia
    Heath, Brandi S.
    Roach, Patrick J.
    Cazares, Lisa
    Semmes, O. John
    ANALYTICAL CHEMISTRY, 2012, 84 (01) : 141 - 148
  • [7] Ambient Mass Spectrometry Imaging: A Comparison of Desorption Ionization by Sonic Spray and Electrospray
    Janfelt, Christian
    Norgaard, Asger W.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (10) : 1670 - 1678
  • [8] Droplet dynamics and ionization mechanisms in desorption electrospray ionization mass spectrometry
    Venter, Andre
    Sojka, Paul E.
    Cooks, R. Graham
    ANALYTICAL CHEMISTRY, 2006, 78 (24) : 8549 - 8555
  • [9] Desorption Electrospray Ionization Mass Spectrometry: 20 Years
    Morato, Nicolas M.
    Cooks, R. Graham
    ACCOUNTS OF CHEMICAL RESEARCH, 2023, 56 (18) : 2526 - 2536
  • [10] Protein analysis by desorption electrospray ionization mass spectrometry
    Venter, Andre R.
    MASS SPECTROMETRY REVIEWS, 2024,