Application of contrast-enhanced ultrasound in the diagnosis of burn depth

被引:2
|
作者
Jiang, Xue [1 ]
Li, Feng [2 ]
Chi, Yunfei [2 ]
Chen, Xin [2 ]
Luo, Yukun [3 ]
Ye, Qinggui [1 ]
Song, Wenjing [1 ]
Li, Guoping [4 ]
机构
[1] Peoples Liberat Army Gen Hosp, Dept Ultrasound Diag, Med Ctr 4, Beijing, Peoples R China
[2] Peoples Liberat Army Gen Hosp, Burns & Plast Dept, Med Ctr 4, Beijing, Peoples R China
[3] Peoples Liberat Army Gen Hosp, Dept Ultrasound Diag, Med Ctr 1, Beijing, Peoples R China
[4] Grand Life Sci & Technol Ltd, Beijing, Peoples R China
关键词
Cutaneous burns; contrast-enhanced ultrasound (CEUS); animal study; pathological diagnosis; DOMAIN IMAGING SFDI; THICKNESS; MODEL; FLOW;
D O I
10.21037/atm-21-3715
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: The diagnosis of burn depth often relies on the subjective judgment of plastic surgeons. Contrast-enhanced ultrasound (CEUS) can visualize the microcirculation well and has potential value in diagnosing the depth of burn wounds. We assessed the depth of the burn wounds by CEUS, and compared the results with histological examination. Methods: Two rhesus monkeys were used, and multiple burn wounds with different depths were made on their backs. The echo of the dermis and subcutaneous tissue were observed for each wound, and the thickness of the dermis was measured. CEUS was performed to evaluate the depth of burn wounds and compared with pathological results. Results: (I) After scalding, dermal tissue edema occurred, and the thickness of the dermis measured by a US tended to increase gradually, related to the time of scalding and the order of measurement. (II) With the prolongation of the burn time, the depth of filling by contrast agent gradually increased, from the superficial dermis to the deep dermis and subcutaneous tissue, indicating that the depth of tissue damage gradually increased. This was consistent with the pathological observation. The thickness of the healthy dermis was about 1.3-1.8 mm, and 2.7-4.1 mm after scalding. The depth of the burn wounds was 0.9-4.1 mm, accounting for 32-100% of the full skin thickness. Conclusions: CEUS is a convenient and fast examination method that is consistent with pathological diagnosis of the depth of burn wounds and could prove valuable for the accurate assessment of burn injuries.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Application of contrast-enhanced ultrasound in the diagnosis of solid pancreatic lesions-A comparison of conventional ultrasound and contrast-enhanced CT
    Fan, Zhihui
    Li, Ying
    Yan, Kun
    Wu, Wei
    Yin, Shanshan
    Yang, Wei
    Xing, Baocai
    Li, Xiaoting
    Zhang, Xiaopeng
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (09) : 1385 - 1390
  • [2] The application of contrast-enhanced ultrasound in the diagnosis of cesarean scar pregnancies
    Li, Hui-Dong
    Zhang, Zhi-Kun
    Guo, Shuang
    Qu, Peng-Peng
    CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 2018, 45 (05): : 731 - 734
  • [3] Application of contrast-enhanced ultrasound in the diagnosis of small breast lesions
    Du, Yan-Ran
    Wu, Yang
    Chen, Man
    Gu, Xin-Gang
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2018, 70 (03) : 291 - 300
  • [4] Application of contrast-enhanced ultrasound in the diagnosis of tuberous vas deferens tuberculosis
    Wenzhi Zhang
    Jie Chu
    Jianping Xu
    Wei Tang
    Gaoyi Yang
    BMC Infectious Diseases, 24
  • [5] The application of contrast-enhanced ultrasound and MicroFlow Imaging in the diagnosis of breast cancer
    Luo, Ting
    Chen, Meizhen
    He, Hailing
    Jiang, Tianan
    Dong, Junjie
    JOURNAL OF MEDICAL ULTRASONICS, 2025, : 245 - 251
  • [6] Application of contrast-enhanced ultrasound in diagnosis and grading of bladder urothelial carcinoma
    Zhang, Hui-ping
    Liang, Rong-xi
    Lin, Xue-ying
    Xue, En-sheng
    Ye, Qin
    Zhu, Yi-fan
    BMC MEDICAL IMAGING, 2024, 24 (01)
  • [7] Application of contrast-enhanced ultrasound in diagnosis and grading of bladder urothelial carcinoma
    Hui-ping Zhang
    Rong-xi Liang
    Xue-ying Lin
    En-sheng Xue
    Qin Ye
    Yi-fan Zhu
    BMC Medical Imaging, 24
  • [8] Application of contrast-enhanced ultrasound in the diagnosis of tuberous vas deferens tuberculosis
    Zhang, Wenzhi
    Chu, Jie
    Xu, Jianping
    Tang, Wei
    Yang, Gaoyi
    BMC INFECTIOUS DISEASES, 2024, 24 (01)
  • [9] Contrast-enhanced ultrasound in diagnosis of gallbladder adenoma
    Yuan, Hai-Xia
    Cao, Jia-Ying
    Kong, Wen-Tao
    Xia, Han-Sheng
    Wang, Xi
    Wang, Wen-Ping
    HEPATOBILIARY & PANCREATIC DISEASES INTERNATIONAL, 2015, 14 (02) : 201 - 207
  • [10] Diagnosis of liver cirrhosis with contrast-enhanced ultrasound
    Liu, Guang-Jian
    Lu, Ming-De
    WORLD JOURNAL OF RADIOLOGY, 2010, 2 (01): : 32 - 36