A New Flicker Contribution Tracing Method Based on Individual Reactive Current Components of Multiple EAFs at PCC

被引:32
作者
Altintas, Erinc [1 ,2 ]
Salor, Ozgul [3 ,4 ]
Cadirci, Isik [3 ,5 ]
Ermis, Muammer [2 ]
机构
[1] TUBITAK, Space Technol Res Inst UZAY, Power Elect Grp, TR-06531 Ankara, Turkey
[2] Middle E Tech Univ, Dept Elect & Elect Engn, TR-06531 Ankara, Turkey
[3] TUBITAK UZAY, Power Elect Grp, TR-06531 Ankara, Turkey
[4] Gazi Univ, Dept Elect & Elect Engn, TR-06500 Ankara, Turkey
[5] Hacettepe Univ, Dept Elect & Elect Engn, TR-06532 Ankara, Turkey
关键词
Electric arc furnace (EAF); flicker contribution; flicker tracing; flickermeter; power quality (PQ); POWER;
D O I
10.1109/TIA.2010.2058835
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, a new flicker contribution tracing method has been proposed to determine the individual flicker contributions of multiple-electric-arc-furnace (EAF) loads to the flicker measured at the point of common coupling (PCC). The proposed method decouples the flicker contribution of the interconnected electricity system from the individual contributions of the loads connected to the measured PCC, using the individual current variations of the loads, and the estimated short-circuit system impedance. It has been shown that the individual flicker contributions of the loads are mainly caused by the variation of their reactive current components. Since the computational complexity of the proposed method is low, it is appropriate for online applications. The algorithm can easily be embedded on a power quality analyzer, which can be employed as a flicker contribution meter. Field data collected at a PCC supplying multi-EAF plants have been used to verify the validity of the proposed method in a successful manner.
引用
收藏
页码:1746 / 1754
页数:9
相关论文
共 9 条
[1]  
[Anonymous], 2003, 61000415 IEC
[2]   Trace of flicker sources by using the quantity of flicker power [J].
Axelberg, Peter G. V. ;
Bollen, Math H. J. ;
Gu, Irene Yu-Hua .
IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (01) :465-471
[3]  
DEMIRCI T, 2007, P IEEE IMTC WARS POL, P1
[4]   A method based on interharmonics for flicker propagation applied to arc furnaces [J].
Hernández, A ;
Mayordomo, JG ;
Asensi, R ;
Beites, LF .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (03) :2334-2342
[5]   Stochastic voltage-flicker power flow [J].
Hong, YY ;
Lee, LH .
IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (01) :407-411
[6]   A V-I slope-based method for flicker source detection [J].
Nassif, AB ;
Nino, EE ;
Xu, WS .
37TH NORTH AMERICAN POWER SYMPOSIUM, PROCEEDINGS, 2005, :364-367
[7]   Short-circuit impedance measurement [J].
Pedersen, KOH ;
Nielsen, AH ;
Poulsen, NK .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2003, 150 (02) :169-174
[8]   Synchronized flicker measurement for flicker transfer evaluation in power systems [J].
Perera, Sarath ;
Robinson, Duane ;
Elphick, Sean ;
Geddey, Don ;
Browne, Neil ;
Smith, Vic ;
Gosbell, Vic .
IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (03) :1477-1482
[9]  
ZHANG D, 2005, P CAN C EL COMP ENG, P549