Electron disequilibrium in high-energy x-ray beams

被引:8
|
作者
Hannallah, D
Zhu, TC
Bjarngard, BE
机构
[1] UNIV FLORIDA,DEPT RADIAT ONCOL,GAINESVILLE,FL 32610
[2] UNIV PENN,DEPT RADIAT ONCOL,PHILADELPHIA,PA 19104
关键词
kerma; dose; scattered photons; electron disequilibrium; build-up region; Monte Carlo;
D O I
10.1118/1.597749
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The ratio between scatter dose and scatter kerma for points on the central axis of 15-MV x-ray beams has been examined by Monte Carlo calculations. This ratio, beta(S)', behaves differently from that between the primary dose and kerma, beta(p)'. Both the primary and scatter components of beta' undergo an initial rapid buildup, however, beta(S)' begins from a much higher surface value. In addition, the depth required for longitudinal electron equilibrium is larger for beta(S)', than for beta(p)'. The variation of beta(S)', with field size and depth is attributed to the spatial variation of scatter kerma in the photon beam. The approximation beta(S)' = 1 is accurate enough for clinical dose-calculation purposes, leading to less than 0.5% error in total dose, while the assumption beta(S)' = beta(p)' may cause up to 2.5% error, relative to the maximum dose, near the surface at 15 MV. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:1867 / 1871
页数:5
相关论文
共 50 条
  • [1] Photonuclear activation of oxygen & copper with high-energy x-ray or electron beams
    Wong, C. J.
    Ackerly, T.
    Binns, D.
    Patterson, B.
    Powell, C. E.
    Qiao, G.
    Solomon, D. H.
    Geso, M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 2126 - +
  • [2] VARIATIONS IN IONOMETRIC DOSE MEASUREMENTS IN HIGH-ENERGY X-RAY AND ELECTRON-BEAMS
    HOLT, JG
    FLEISCHMAN, RC
    BUFFA, A
    MEDICAL PHYSICS, 1981, 8 (04) : 560 - 561
  • [3] A COMPARISON OF CHEMICAL AND IONIZATION DOSIMETRY FOR HIGH-ENERGY X-RAY AND ELECTRON-BEAMS
    DUROCHER, JJG
    BOESE, H
    CORMACK, DV
    HOLLOWAY, AF
    MEDICAL PHYSICS, 1981, 8 (02) : 197 - 202
  • [4] MULTICHANNEL SEMICONDUCTOR-DETECTORS FOR HIGH-ENERGY X-RAY AND ELECTRON-BEAMS
    NARUSE, Y
    KOBAYASHI, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 196 (01): : 173 - 175
  • [5] PHOTOACTIVATION AUTORADIOGRAPHS FROM HIGH-ENERGY X-RAY BEAMS
    HORN, RA
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 565 - 566
  • [6] CONTRAST ENHANCEMENT IN HIGH-ENERGY X-RAY THERAPY BEAMS
    LUXTON, G
    GOMEZ, R
    MEDICAL PHYSICS, 1984, 11 (03) : 375 - 375
  • [7] PHOTONEUTRON PRODUCTION IN DETECTORS IN HIGH-ENERGY X-RAY BEAMS
    KUSHELEVSKY, AP
    SHANI, G
    NUCLEAR INSTRUMENTS & METHODS, 1976, 137 (01): : 71 - 73
  • [8] Doses near the surface in high-energy x-ray beams
    Department of Radiation Oncology, Roger Williams Cancer Center, Providence, RI 02908, United States
    MED. PHYS., 4 (465-468):
  • [9] ELECTRON CONTAMINATION OF A HIGH-ENERGY X-RAY BEAM
    PADIKAL, TN
    DEYE, JA
    PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (06): : 1086 - 1092
  • [10] MATRIX DOSIMETER TO STUDY UNIFORMITY OF HIGH-ENERGY X-RAY BEAMS
    JOHNS, HE
    RAWLINSON, JA
    TAYLOR, WB
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1974, 120 (01) : 192 - 201