Diamond/Porous Titanium Nitride Electrodes With Superior Electrochemical Performance for Neural Interfacing

被引:14
|
作者
Meijs, Suzan [1 ]
McDonad, Matthew [2 ]
Sorensen, Soren [3 ]
Rechendorff, Kristian [3 ]
Fekete, Ladislav [4 ]
Klimsa, Ladislav [4 ]
Petrak, Vaclav [4 ,6 ]
Rijkhoff, Nico [1 ]
Taylor, Andrew [4 ]
Nesladek, Milos [2 ]
Pennisi, Cristian P. [5 ]
机构
[1] Aalborg Univ, SMI, Dept Hlth Sci & Technol, Aalborg, Denmark
[2] Univ Hasselt, Inst Mat Res, Diepenbeek, Belgium
[3] Danish Technol Inst, Mat Div, Aarhus, Denmark
[4] Czech Acad Sci, Inst Phys, Dept Funct Mat, Prague, Czech Republic
[5] Aalborg Univ, Dept Hlth Sci & Technol, Lab Stem Cell Res, Aalborg, Denmark
[6] Czech Tech Univ, Fac Biomed Engn, Dept Nat Sci, Kladno, Czech Republic
关键词
Boron-doped diamond; Electrical stimulation; Electrochemistry; Implantable electrodes; Neural interfaces; Neural prosthesis; Porous diamond; Titanium nitride;
D O I
10.3389/fbioe.2018.00171
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Robust devices for chronic neural stimulation demand electrode materials which exhibit high charge injection (Q(inj)) capacity and long-term stability. Boron-doped diamond (BDD) electrodes have shown promise for neural stimulation applications, but their practical applications remain limited due to the poor charge transfer capability of diamond. In this work, we present an attractive approach to produce BDD electrodes with exceptionally high surface area using porous titanium nitride (TiN) as interlayer template. The TiN deposition parameters were systematically varied to fabricate a range of porous electrodes, which were subsequently coated by a BDD thin-film. The electrodes were investigated by surface analysis methods and electrochemical techniques before and after BDD deposition. Cyclic voltammetry (CV) measurements showed a wide potential window in saline solution (between -1.3 and 1.2 V vs. Ag/AgCI). Electrodes with the highest thickness and porosity exhibited the lowest impedance magnitude and a charge storage capacity (CSC) of 253 mC/cm(2), which largely exceeds the values previously reported for porous BDD electrodes. Electrodes with relatively thinner and less porous coatings displayed the highest pulsing capacitances (C-pulse), which would be more favorable for stimulation applications. Although BDD/TiN electrodes displayed a higher impedance magnitude and a lower C-pulse as compared to the bare TiN electrodes, the wider potential window likely allows for higher Q(i)(nj) without reaching unsafe potentials. The remarkable reduction in the impedance and improvement in the charge transfer capacity, together with the known properties of BDD films, makes this type of coating as an ideal candidate for development of reliable devices for chronic neural interfacing.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Ultra-porous titanium nitride as a dual-action supercapacitor for implantable neural interfacing electrodes
    Arpa, Jeanelle
    Rechendorff, Kristian
    Wismayer, Pierre Schembri
    Mallia, Bertram
    MATERIALS CHEMISTRY AND PHYSICS, 2022, 289
  • [2] Ultra-porous titanium nitride as a dual-action supercapacitor for implantable neural interfacing electrodes
    Arpa, Jeanelle
    Rechendorff, Kristian
    Wismayer, Pierre Schembri
    Mallia, Bertram
    Materials Chemistry and Physics, 2022, 289
  • [3] Biofouling resistance of boron-doped diamond neural stimulation electrodes is superior to titanium nitride electrodes in vivo
    Meijs, S.
    Alcaide, M.
    Sorensen, C.
    McDonald, M.
    Sorensen, S.
    Rechendorff, K.
    Gerhardt, A.
    Nesladek, M.
    Rijkhoff, N. J. M.
    Pennisi, C. P.
    JOURNAL OF NEURAL ENGINEERING, 2016, 13 (05)
  • [4] TITANIUM NITRIDE NANOTUBES ELECTRODES FOR CHRONIC NEURAL STIMULATION
    Chen, Gui
    Gatti, Marcella
    Cheng, Mark Ming-Cheng
    2019 20TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS & EUROSENSORS XXXIII (TRANSDUCERS & EUROSENSORS XXXIII), 2019, : 1662 - 1665
  • [5] Porous diamond with high electrochemical performance
    Hebert, Clement
    Scorsone, Emmanuel
    Mermoux, Michel
    Bergonzo, Philippe
    CARBON, 2015, 90 : 102 - 109
  • [6] In Vitro Study of Titanium Nitride Electrodes for Neural Stimulation
    Aryan, Naser Pour
    Bin Asad, Mohammad Imam Hasan
    Brendler, Christian
    Kibbel, Steffen
    Heusel, Gerhard
    Rothermel, Albrecht
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2866 - 2869
  • [7] Electrochemical Behavior of Porous Titanium Electrodes in Phosphoric Acid
    A. I. Kushmyruk
    O. V. Kosohin
    O. V. Linyucheva
    V. A. Reveko
    Yu. S. Miroshnychenko
    Materials Science, 2015, 51 : 429 - 435
  • [8] Diamond/porous titanium three-dimensional hybrid electrodes
    Braga, N. A.
    Cairo, C. A. A.
    Matsushima, J. T.
    Baldan, M. R.
    Ferreira, N. G.
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2010, 14 (02) : 313 - 321
  • [9] Long term performance of 2.4 mm(2) membrane porous titanium-nitride electrodes
    Guerola, M
    PACEMAKER LEADS 1997, 1997, : 281 - 284
  • [10] ELECTROCHEMICAL BEHAVIOR OF POROUS TITANIUM ELECTRODES IN PHOSPHORIC ACID
    Kushmyruk, A. I.
    Kosohin, O. V.
    Linyucheva, O. V.
    Reveko, V. A.
    Miroshnychenko, Yu. S.
    MATERIALS SCIENCE, 2015, 51 (03) : 429 - 435