Out-of-focus effects on microscale schlieren measurements of mass transport in a microfluidic device

被引:0
|
作者
Chen, Shao-Tuan [1 ]
Sun, Chen-li [1 ]
机构
[1] Natl Taiwan Univ, Dept Mech Engn, 1 Sec 4 Roosevelt Rd, Taipei 10617, Taiwan
关键词
microscale schlieren technique; depth of field; weighting function; concentration gradient; quantitation; microfluidics; out-of-focus effect; FIELD;
D O I
10.1088/0957-0233/27/8/085203
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The microscale schlieren technique provides a means for a non-invasive, full-field measurement for mixing microfluidics with excellent sensitivity and resolution. Nevertheless, an out-of-focus effect due to microscopic optics may lead to undesirable errors in quantifying the gradient information at high degrees of magnification. If the channel in the microfluidic device under study is too deep, light deflection caused by inhomogeneity located far from the focal plane may contributes little to the intensity change on the image plane. To address this issue, we propose the use of a weighting function that approximates a Gaussian profile with an optical-system-dependable width. We assume that the resultant intensity change is proportional to a weighted sum of the gradient across the channel depth and acquire microschlieren images of fluid mixing in a T-junction microchannel at various positions along the optical axis. For each objective, the width of the weighting function is then determined iteratively by curve fitting the ratio of changes in grayscale readouts for out-of-focus and focus micro-schlieren images. The standard deviation in the Gaussian distribution facilitates the quantification of the out-of-focus effect. In addition, we measure the sensitivities of a microscale schlieren system equipped with different objectives and compare the values to the model. Despite its better resolution, we find that an objective with higher magnification suffers from a more severe out-of-focus effect and a loss of sensitivity. Equations are proposed for estimations of the standard deviation and the sensitivity of microscale schlieren measurements. The outcome will facilitate the selection of proper microchannel depths for various microscale schlieren systems or vice versa, thus improving the precision of micro-schlieren measurements in microfluidic devices.
引用
收藏
页数:10
相关论文
共 17 条
  • [1] Analyzing Mixing Inhomogeneity in a Microfluidic Device by Microscale Schlieren Technique
    Sun, Chen-li
    Hsiao, Tzu-hsun
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2015, (100):
  • [2] On the background design for microscale background-oriented schlieren measurements of microfluidic mixing
    Sun, Chen-li
    Hsiao, Tzu-hsun
    MICROFLUIDICS AND NANOFLUIDICS, 2014, 17 (02) : 375 - 391
  • [3] On the background design for microscale background-oriented schlieren measurements of microfluidic mixing
    Chen-li Sun
    Tzu-hsun Hsiao
    Microfluidics and Nanofluidics, 2014, 17 : 375 - 391
  • [4] X-ray Fourier Ptychography for Out-Of-Focus Measurements
    Wakonig, Klaus
    Diaz, Ana
    Chiriotti, Sabina
    Bergamaschi, Anna
    Bonnin, Anne
    Stampanoni, Marco
    Menzel, Andreas
    X-RAY NANOIMAGING: INSTRUMENTS AND METHODS IV, 2019, 11112
  • [5] CONTRAST EFFECTS IN OUT-OF-FOCUS IMAGES OF A P-N-JUNCTION
    MERLI, PG
    MISSIROLI, GF
    POZZI, G
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 1973, 20 (02): : K87 - +
  • [6] Out-of-focus effects on particle image visibility and correlation in microscopic particle image velocimetry
    Olsen, MG
    Adrian, RJ
    EXPERIMENTS IN FLUIDS, 2000, 29 (Suppl 1) : S166 - S174
  • [7] Out-of-focus effects on particle image visibility and correlation in microscopic particle image velocimetry
    M. G. Olsen
    R. J. Adrian
    Experiments in Fluids, 2000, 29 : S166 - S174
  • [8] Out-of-focus holography at the Effelsberg telescope: Systematic measurements of the surface of a 100 m telescope using OOF holography
    Cassanelli T.
    Bach U.
    Winkel B.
    Kraus A.
    Astronomy and Astrophysics, 2024, 687
  • [9] Out-of-focus signal rejection for in vivo pO2 measurements using two-photon phosphorescence lifetime microscopy
    Pian, Qi
    Li, Baoqiang
    Sencan-Egilmez, Ikbal
    Cheng, Xiaojun
    Dubb, Jay
    Huang, Xinyue
    Fu, Buyin
    Allu, Srinivasa Rao
    Yaseen, Mohammad Abbas
    Devor, Anna
    Vinogradov, Sergei A.
    Sakadzic, Sava
    BIOMEDICAL OPTICS EXPRESS, 2025, 16 (01): : 159 - 176
  • [10] Microscale schlieren visualization of near-bubble mass transport during boiling of 2-propanol/water mixtures in a square capillary
    Sun, Chen-li
    Huang, Chien-Yuan
    EXPERIMENTS IN FLUIDS, 2014, 55 (07)