A Feasibility Study of Off-the-Shelf Scalloped Stent-Grafts in Acute Type B Aortic Dissection

被引:6
|
作者
van der Weijde, Emma [1 ]
Bakker, Olaf J. [2 ]
Kamman, Arnoud V. [3 ]
van Herwaarden, Joost A. [2 ]
Trimarchi, Santi [3 ]
Vos, Jan Albert [4 ]
Heijmen, Robin H. [1 ]
机构
[1] St Antonius Hosp, Dept Cardiothorac Surg, Nieuwegein, Netherlands
[2] Univ Med Ctr Utrecht, Dept Vasc & Endovasc Surg, Utrecht, Netherlands
[3] Univ Milan, Thorac Aort Res Ctr, Policlin San Donato IRCCS, Milan, Italy
[4] St Antonius Hosp, Dept Intervent Radiol, Nieuwegein, Netherlands
关键词
computed tomography angiography; feasibility study; left subclavian artery; off-the-shelf stent-graft; proximal landing zone; scallop; thoracic endovascular aortic repair; type B aortic dissection; LEFT SUBCLAVIAN ARTERY; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; ENDOVASCULAR REPAIR; NEUROLOGIC COMPLICATIONS; ANEURYSM REPAIR; OUTCOMES; REGISTRY; ARCH; EXPERIENCE; MANAGEMENT;
D O I
10.1177/1526602817726329
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To evaluate the applicability of an off-the-shelf scalloped stent-graft to preserve left subclavian artery (LSA) flow in thoracic endovascular aortic repair (TEVAR) for acute type B aortic dissection. Methods: The computed tomography angiograms (CTA) of 70 consecutive patients (median age 64 years; 44 men) with acute Stanford type B aortic dissection were retrospectively analyzed to identify patients in whom a short proximal landing zone (<15 mm from the retrogradely dissected wall layers) would require LSA overstenting during TEVAR. A scalloped stent-graft was deemed possible in those patients with the intimal entry tear located at least 20 mm distant from the LSA ostium. Results: The LSA needed to be covered in 56 (80%) patients. Of these, an off-the-shelf scalloped stent-graft would have been applicable in 23 (41%) patients. In the latter group, the median aortic diameter was 31 mm (range 26-37), the median length of the LSA ostium was 13 mm (range 10-20), and the median width of the LSA ostium was 15 mm (range 11-24). Three differently sized off-the-shelf stent-grafts with the largest scallop possible could have adequately treated 20 (36%) of the 56 patients in the acute phase. Conclusion: In this single-center imaging-based study, involvement of the LSA in the setting of acute type B aortic dissection was seen in 80% of patients treated with TEVAR. Three off-the-shelf stent-grafts would suffice to treat one-third of these acute type B aortic dissections and may offer a relatively simple solution to preserve LSA flow, thereby lowering the risk of malperfusion of the (posterior) cerebrum, spinal cord, and left arm in an urgent/emergent setting.
引用
收藏
页码:819 / 824
页数:6
相关论文
共 50 条
  • [1] Treatment of acute aortic type B dissection with stent-grafts
    Hausegger, KA
    Tiesenhausen, K
    Schedlbauer, T
    Oberwalder, P
    Tauss, J
    Rigler, B
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 24 (05) : 306 - 312
  • [2] Treatment of Acute Aortic Type B Dissection with Stent-Grafts
    K.A. Hausegger
    K. Tiesenhausen
    P. Schedlbauer
    P. Oberwalder
    J. Tauss
    B. Rigler
    CardioVascular and Interventional Radiology, 2001, 24 : 306 - 312
  • [3] Comparison of anatomic feasibility of three different multibranched off-the-shelf stent-grafts designed for thoracoabdominal aortic aneurysms
    Bertoglio, Luca
    Grandi, Alessandro
    Carta, Niccolo
    Cambiaghi, Tommaso
    Bilman, Victor
    Melissano, Germano
    Chiesa, Roberto
    JOURNAL OF VASCULAR SURGERY, 2021, 74 (05) : 1472 - +
  • [4] Endovascular stent-grafts for acute and chronic type B aortic dissection: comparison of clinical outcomes
    David Jayakar
    Journal of Geriatric Cardiology, 2007, (02) : 72 - 72
  • [5] Endovascular stent-grafts for acute and chronic type B aortic dissection:comparison of clinical outcomes
    JING QuanminHAN YalingWANG XiaozengDENG JieLUAN BoJIN HongxuLIU Xiaojiang and LI Fei Department of CardiologyShenyang Northern Hospital ShenyangLiaoning China
    中华医学杂志(英文版), 2008, (22) : 2213 - 2217
  • [6] Endovascular stent-grafts for acute and chronic type B aortic dissection: comparison of clinical outcomes
    Jing Quan-min
    Han Ya-ling
    Wang Xiao-zeng
    Deng Jie
    Luan Bo
    Jin Hong-xu
    Liu Xiao-jiang
    Li Fei
    CHINESE MEDICAL JOURNAL, 2008, 121 (22) : 2213 - 2217
  • [7] Outcomes of Off-the-Shelf t-Branch Stent-Grafts in Endovascular Repair of Thoracoabdominal Aortic Aneurysms
    Bhandari, Apoorva
    Mahmood, Daniyal N.
    Rocha, Rodolfo V.
    Forbes, Samantha
    Tan, Kong T.
    Ouzounian, Maral
    Chung, Jennifer
    Lindsay, Thomas F.
    JOURNAL OF VASCULAR SURGERY, 2021, 74 (03) : E118 - E118
  • [8] Treatment of Stanford type B aortic dissection with stent-grafts: Preliminary results
    Czermak, BV
    Waldenberger, P
    Fraedrich, G
    Dessl, AH
    Roberts, KE
    Bale, RJ
    Perkmann, R
    Jaschke, WR
    RADIOLOGY, 2000, 217 (02) : 544 - 550
  • [9] Treatment of Stanford type B aortic dissection with stent-grafts: preliminary results
    Czermak, B
    Waldenberger, P
    Fraedrich, G
    Dessl, A
    Roberts, K
    Bale, R
    Perkmann, R
    Jascke, W
    JOURNAL OF VASCULAR SURGERY, 2001, 33 (05) : 1136 - 1137
  • [10] Effects of endoluminal stent-grafts on acute aortic dissection in dogs
    Yunoki, K
    Uchida, H
    Sano, S
    Shimizu, N
    ACTA MEDICA OKAYAMA, 1998, 52 (02) : 89 - 95