Beam configuration and physical parameters of clinical high energy photon beam for total body irradiation (TBI)

被引:7
|
作者
Ravichandran, Ramamoorthy
Binukumar, Johnson Pichi
Davis, Chirayathmanjiyil Antony
Sivakumar, Somangali Sathiyamurthy
Krishnamurthy, Kammari
Al Mandhari, Zahid [1 ]
Rajan, Balakrishnan [1 ]
机构
[1] Royal Hosp, Natl Oncol Ctr, Dept Radiat Oncol, Seeb Muscat, Oman
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2011年 / 27卷 / 03期
关键词
Total body irradiation (TBI); Depth dose data for TBI; Beam spoiler for TBI; Clinical dosimetry for TBI; PHANTOM;
D O I
10.1016/j.ejmp.2010.10.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To start total body irradiation (TBI) treatments, physical parameters are measured for a magna field irradiation. Methods and Materials: 6 MV photon beam from Clinac 600 CD linear accelerator (Varian, USA) with fully opened collimator at 45 degrees and gantry at 270 degrees provided a diamond shaped magna field with diagonal dimension 224 cm at 4.0 m source skin distance (SSD). The flatness of the radiation field was measured in the presence of locally designed acrylic beam spoiler and beam flatness filter. Central Axis Depth dose data (CADD), tissue maximum ratios and entrance dose pattern are measured using large phantoms. Methods for clinical dose estimation using semiconductor diodes and TLD were standardized. Results: PVC beam flattener at the shielding tray position and the presence of acrylic beam spoiler in the radiation field provided a flatness of 100.15% +/- 0.44% compared to open beam flatness 101.6 +/- 1.5%. A reduction of 2% in percentage depth dose was observed at 10 cm depth in the presence of 15 mm acrylic beam spoiler. However, no changes are observed in the TMRs with presence of beam spoiler. The measured ionization ratios clearly showed change of beam quality with the introduction of beam spoiler. The presence of 15 mm beam spoiler ensured entrance dose 100% at skin and remaining unchanged within 1% upto a depth of 10 mm. Phantom measurements show good agreement between calculated and measured doses. Conclusions: The paper recommends use of modified CADD parameters for treatment planning, if calibration of output is carried out in the presence of beam spoiler. (c) 2010 Published by Elsevier Ltd on behalf of Associazione Italiana di Fisica Medica.
引用
收藏
页码:163 / 168
页数:6
相关论文
共 50 条
  • [1] Investigation on using high-energy proton beam for total body irradiation (TBI)
    Zhang, Miao
    Qin, Nan
    Jia, Xun
    Zou, Wei J.
    Khan, Atif
    Yue, Ning J.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05): : 90 - 98
  • [2] UTILIZATION OF HIGH-ENERGY PHOTON BEAM FOR WHOLE-BODY IRRADIATION
    AGET, H
    VANDYK, J
    LEUNG, PMK
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 571 - 571
  • [3] UTILIZATION OF A HIGH-ENERGY PHOTON BEAM FOR WHOLE-BODY IRRADIATION
    AGET, H
    VANDYK, J
    LEUNG, PMK
    RADIOLOGY, 1977, 123 (03) : 747 - 752
  • [4] CLINICAL ELECTRON BEAM CONFIGURATION AND PHYSICAL PARAMETERS FOR TOTAL SKIN ELECTRON TREATMENT(TSET)
    Ravichandran, R.
    Krishnamurthy, K.
    Sivakumar, S. S.
    Davis, C. A.
    Mohanti, B. K.
    JOURNAL OF MEDICAL PHYSICS, 2005, 30 (02) : 60 - 65
  • [5] Theoretical Investigation On Using High Energy Proton Beam for Total-Body-Irradiation
    Zhang, M.
    Zou, J.
    Chen, T.
    Yue, N.
    MEDICAL PHYSICS, 2015, 42 (06) : 3509 - 3509
  • [6] Equilibrium electron beam parameters of the High Energy Photon Source
    Xu, Haisheng
    Meng, Cai
    Peng, Yuemei
    Tian, Saike
    Wang, Na
    Cui, Xiaohao
    Du, Chongchong
    Duan, Zhe
    Guo, Yuanyuan
    He, Ping
    Huang, Xiyang
    Ji, Daheng
    Ji, Hongfei
    Jiao, Yi
    Li, Jingyi
    Li, Nan
    Li, Xiaoyu
    Lu, Xiaohan
    Liang, Pengfei
    Pan, Weimin
    Qu, Huamin
    Wang, Bin
    Wang, Jiuqing
    Wei, Yuanyuan
    Wan, Jinyu
    Xu, Gang
    Yan, Fang
    Yu, Chenghui
    Yue, Sen
    Zhang, Xiang
    Zhao, Yaliang
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2023, 7 (02) : 279 - 287
  • [7] Equilibrium electron beam parameters of the High Energy Photon Source
    Haisheng Xu
    Cai Meng
    Yuemei Peng
    Saike Tian
    Na Wang
    Xiaohao Cui
    Chongchong Du
    Zhe Duan
    Yuanyuan Guo
    Ping He
    Xiyang Huang
    Daheng Ji
    Hongfei Ji
    Yi Jiao
    Jingyi Li
    Nan Li
    Xiaoyu Li
    Xiaohan Lu
    Pengfei Liang
    Weimin Pan
    Huamin Qu
    Bin Wang
    Jiuqing Wang
    Yuanyuan Wei
    Jinyu Wan
    Gang Xu
    Fang Yan
    Chenghui Yu
    Sen Yue
    Xiang Zhang
    Yaliang Zhao
    Radiation Detection Technology and Methods, 2023, 7 : 279 - 287
  • [8] Influence of high-energy photon beam irradiation on pacemaker operation
    Mouton, J
    Haug, R
    Bridier, A
    Dodinot, B
    Eschwege, F
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (16): : 2879 - 2893
  • [9] Dose uniformity in the total body irradiation technique using 15 MV photon beam
    Kawa-Iwanicka, A
    Lobodziec, W
    Iwanicki, T
    Dybek, M
    Gawelko, J
    Czerwinska, D
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2004, 20 : 144 - 146
  • [10] TOTAL-BODY IRRADIATION WITH A SWEEPING BEAM
    PLA, M
    CHENERY, SG
    PODGORSAK, EB
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (01): : 83 - 89