Accuracy of routine MRI in lesions of the supraspinatus tendon -: Comparison with surgical findings

被引:0
|
作者
Schröder, RJ
Bostanjoglo, M
Kääb, M
Herzog, H
Hidajat, N
Röttgen, R
Mäurer, J
Felix, R
机构
[1] Humboldt Univ, Klin Strahlenheilkunde, Charite, D-13353 Berlin, Germany
[2] Humboldt Univ, Klin Unfall & Wiederherstellungschirurg, Charite, D-13353 Berlin, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2003年 / 175卷 / 07期
关键词
shoulder; supraspinatus tendon; gadolinium-DTPA; MRI; quality assurance;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine the correlation of the extent of lesions of the supraspinatus tendon in MRI's of the shoulder with surgical or arthroscopic findings using the classification of Snyders and Batemann, respectively. Materials and Methods: The preoperative MRI's of 80 patients (age: 16-76/47.4+/-14.0 years) which were performed due to various complaints of the shoulder were analyzed retrospectively by two experienced and blinded radiologists. We evaluated the incidence and the extent of partial or complete ruptures of the supraspinatus tendon. After MRI, an arthroscopic or open surgical intervention was performed (= gold standard). Various MR-scanners were used with a field strength of 1.0 T (17 cases), or 1.5 T (63 cases) and flexible or inflexible arthro coils. Additionally to plain MRI, 38 of 80 patients underwent contrast enhanced MRI. The MR and the surgical or arthroscopic findings were compared and statistically analyzed. Results: Neglecting the localization and the extent of discontinuity of the supraspinatus tendon, the sensitivity of the 80 MRI's was 0.93, the specificity 0.69, and the accuracy 0.85. The sensitivity increased to 0.96 with constant specificity and an accuracy of 0.83 excluding the lesions with an extent below 1 cm. Compared with non-enhanced examinations, the contrast enhanced MRI revealed higher sensitivity (+ 7%, 0.89 vs. 0.96), higher specificity (+ 11 %, 0.64 vs. 0.75), and higher accuracy (+ 8 %, 0.81 vs. 0.89) in depicting lesions of the supraspinatus tendon at all. On T,weighted images, the detection of lesions at all and the differentiation between partial and complete ruptures were improved significantly by contrast enhancement, especially in lesions with an extent below 1 cm. Diagnostic failures were seen in examinations without intravenous contrast application, artifacts, extent of the lesion below 1 cm, differentiating between degeneration and partial rupture of the tendon, differentiating between severely degenerated tendons with partial rupture and complete rupture, and covered ruptures. Conclusions: The performance and consecutively the analysis of the widely used MRI of the shoulder is often not sufficiently reliable in its present routine form. To be able to compete with other imaging modalities such as sonography, standardized MR protocol, contrast enhancement as needed, avoiding the described source of failure, and an exact analysis should be applied.
引用
收藏
页码:920 / 928
页数:9
相关论文
共 50 条
  • [1] MRI after reconstruction of the supraspinatus tendon: MR-tomographic findings
    von Engelhardt, LV
    von Falkenhausen, M
    Fahmy, U
    Wallny, T
    Schmitt, O
    Kraft, CN
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2004, 142 (05): : 586 - 591
  • [2] Accuracy of MRI findings in chronic lateral ankle ligament injury: Comparison with surgical findings
    Park, H. -J.
    Cha, S. -D.
    Kim, S. S.
    Rho, M. -H.
    Kwag, H. -J.
    Park, N. -H.
    Lee, S. -Y.
    CLINICAL RADIOLOGY, 2012, 67 (04) : 313 - 318
  • [3] Supraspinatus tendon tears: comparison of US and MR arthrography with surgical correlation
    Francesco S. Ferrari
    Simone Governi
    Francesca Burresi
    Francesco Vigni
    Paolo Stefani
    European Radiology, 2002, 12 : 1211 - 1217
  • [4] Supraspinatus tendon tears: comparison of US and MR arthrography with surgical correlation
    Ferrari, FS
    Governi, S
    Burresi, F
    Vigni, F
    Stefani, P
    EUROPEAN RADIOLOGY, 2002, 12 (05) : 1211 - 1217
  • [5] Sono-elastography findings of supraspinatus tendon in supraspinatus tendinopathy and tear: comparison study with magnetic resonance imaging
    Gadalla, Amr A. Elfattah Hassan
    Hassanein, Gehad Ramadan
    El Azizy, Hatem Mohammed Saeed
    Mohammed, Walid Reda
    Elliethy, Neiven Ezzat Mohammed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2023, 54 (01):
  • [6] Sono-elastography findings of supraspinatus tendon in supraspinatus tendinopathy and tear: comparison study with magnetic resonance imaging
    Amr A. Elfattah Hassan Gadalla
    Gehad Ramadan Hassanein
    Hatem Mohammed Saeed El Azizy
    Walid Reda Mohammed
    Neiven Ezzat Mohammed Elliethy
    Egyptian Journal of Radiology and Nuclear Medicine, 54
  • [7] Detection and characterization of glenohumeral chondral and osteochondral lesions: Comparison of MRI and surgical findings
    Thompson, DB
    Beall, DP
    Ly, JQ
    Jones, TP
    McCollum, MJ
    Campbell, SE
    RADIOLOGY, 2002, 225 : 218 - 218
  • [8] Lesions of the supraspinatus tendon - Degeneration, rupture and calcification
    Wilson, CL
    ARCHIVES OF SURGERY, 1943, 46 (03) : 307 - 325
  • [9] Obscure lesions of the shoulder, rupture of the supraspinatus tendon
    Codman, EA
    BOSTON MEDICAL AND SURGICAL JOURNAL, 1927, 196 : 381 - 387
  • [10] 3.0-T MRI of the supraspinatus tendon
    Magee, Thomas
    Williams, David
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (04) : 881 - 886