Wide Area Uniform Illumination Scheme Using LED Matrix for Optogenetic Cardiac Pacing

被引:2
|
作者
Izadi, Ida [1 ,2 ]
Dusend, Vanessa [3 ]
Takrouni, Abdulaziz [1 ,2 ]
Nudds, Noreen [1 ]
Gradkowski, Kamil [1 ]
O'Brien, Peter [1 ]
Sasse, Philipp [3 ]
Corbett, Brian [1 ]
机构
[1] Tyndall Natl Inst, Lee Mailings Complex, Cork T12 R5CP, Ireland
[2] Univ Coll Cork, Sch Elect Engn, Western Rd, Cork T12 R229, Ireland
[3] Univ Bonn, Med Fac, Inst Physiol 1, D-53127 Bonn, Germany
基金
爱尔兰科学基金会;
关键词
LED; homogeneity; cardiac pacing; optogenetic; QRS; threshold; optical power; Channelrhodopsin2; phototoxicity; IN-VITRO; LIGHT; CORTEX; MUSCLE;
D O I
10.3390/photonics8110499
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Control of heart rhythm is vital in the case of arrhythmia. Cardiac optogenetics is a promising technique to replace electrical stimulation in a next generation of pacemakers and defibrillators. Therefore, further research towards optimizing light delivery methods is essential. A major requirement is the uniform stimulation of all cells in the area of interest while reducing side effects such as photodamage. Here, a 2 x 2 blue (470 nm, InGaN-based) light-emitting diode (LED) optoelectronic module for uniform ex vivo cardiac muscle illumination is demonstrated. It satisfies two important requirements in optogenetics, which are high illumination homogeneity and high irradiance. CCD camera images show an average 90% homogeneity over the central illumination area of close to 38 mm2 at 1 cm distance from the light source. The module is used to perform physiological experiments on channelrhodopsin 2-expressing Langendorff-perfused mouse hearts. Successful ventricular pacing is obtained for an optical power density threshold below 2 mW/mm2 with light pulses as short as 1 ms. For 10 ms long pulses, the threshold was below 0.2 mW/mm2. The large homogeneous illumination area enabled optogenetic pacing with less than half the optical power of previous attempts with smaller areas of 2 mm2 and thus, presumably, will result in less phototoxicity.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Design of LED Light Source for Uniform Illumination in Large Area
    Sun, Jie
    Zhang, Jingwen
    FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY III, PTS 1-3, 2013, 401 : 465 - 468
  • [2] LED Arrays Design for Large Area and High Uniform Illumination
    Li Pulin
    Wu Lingling
    Chen Jing
    Zhan Chunlian
    Yu Huan
    LASER & OPTOELECTRONICS PROGRESS, 2024, 61 (13)
  • [3] Hybrid GaN LED/elastomer membrane for uniform area illumination
    Farrell, F.
    Xie, E.
    Guilhabert, B.
    Haughey, A-M.
    Connolly, P.
    Dawson, M. D.
    Laurand, N.
    2018 IEEE PHOTONICS CONFERENCE (IPC), 2018,
  • [4] Digital LED Desk Lamp with Automatic Uniform Illumination Area by Using Two Accelerometers and Halftone Method
    Hung, Chi-Huang
    Bai, Ying-Wen
    Hsu, Jung-Ming
    Chen, Po-Wen
    Wu, Hsu-Yao
    18TH IEEE INTERNATIONAL SYMPOSIUM ON CONSUMER ELECTRONICS (ISCE 2014), 2014,
  • [5] Efficient termination of cardiac arrhythmias using optogenetic resonant feedback pacing
    Hussaini, S.
    Kyzy, A. Mamyraiym
    Schroeder-Schetelig, J.
    Laedke, S. L.
    Venkatesan, V.
    Diaz-Maue, L.
    Uribe, R. A. Quinonez
    Richter, C.
    Biktashev, V. N.
    Majumder, R.
    Krinski, V.
    Luther, S.
    CHAOS, 2024, 34 (03)
  • [6] Using spherical aberrations of a singlet lens to get a uniform LED illumination
    Gao, GJ
    Li, L
    Huang, YF
    Optical Design and Testing II, Pts 1 and 2, 2005, 5638 : 551 - 560
  • [7] Design of LED collimator for uniform illumination using two freeform lenses
    Zeng, Jiazhong
    Li, Xiufeng
    Ge, Peng
    OPTICA APPLICATA, 2018, 48 (03) : 413 - 420
  • [8] Optogenetic manipulation of cardiac repolarization gradients using sub-threshold illumination
    Marchal, Gerard A.
    Biasci, Valentina
    Loew, Leslie M.
    Biggeri, Annibale
    Campione, Marina
    Sacconi, Leonardo
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [9] Feasibility of a wide area illumination scheme for reliable Raman measurement of petroleum products
    Kim, Jaejin
    Han, Jintae
    Noh, Jaegeun
    Chung, Hoeil
    APPLIED SPECTROSCOPY, 2007, 61 (07) : 686 - 693
  • [10] LED Uniform Illumination Using Double Linear Fresnel Lenses for Energy Saving
    Ngoc Hai Vu
    Thanh Tuan Pham
    Shin, Seoyong