Determination of ambroxol in human plasma using LC-MS/MS

被引:46
|
作者
Kim, H
Yoo, JY
Han, SB
Lee, HJ
Lee, KR
机构
[1] Seoul Med Sci Inst, Seoul Clin Labs, Dept Pharmacokinet, Yongsan Gu, Seoul 140809, South Korea
[2] BioCore Co Ltd, Dept Drug Dev Sci, Seoul 137130, South Korea
关键词
tandem mass spectrometry; liquid chromatography; multiple reaction monitoring (MRM); ambroxol; domperidone; LIQUID-CHROMATOGRAPHIC DETERMINATION; PRINCIPAL-COMPONENTS-ANALYSIS; QUALITATIVE ORGANIC-ANALYSIS; IDENTIFICATION; ELECTROPHORESIS; FLUIDS; URINE; DRUGS; ASSAY;
D O I
10.1016/S0731-7085(03)00059-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and selective liquid chromatographic method coupled with tandem mass spectrometry (LC-MS/MS) was developed for the quantification of ambroxol in human plasma. Domperidone was used as internal standard, with plasma samples extracted using diethyl ether under basic condition. A centrifuged upper layer was then evaporated and reconstituted with 200 mul methanol. The reconstituted samples were injected into a C-18 XTerra NIS column (2.1 x 30 mm) with 3.5 mum particle size. The analytical column lasted for at least 600 injections. The mobile phase was composed of 20 mM ammonium acetate in 90% acetonitrile (pH 8.8), with flow rate at 250 mul/min. The mass spectrometer was operated in positive ion mode using turbo electrospray ionization. Nitrogen was used as the nebulizer, curtain, collision, and auxiliary gases. Using MS/MS with multiple reaction monitoring (MRM) mode, ambroxol was detected without severe interferences from plasma matrix. Ambroxol produced a protonated precursor ion ([M+H](+)) at m/z 379 and a corresponding product ion at m/z 264. And internal standard (domperidone) produced a protonated precursor ion ([M+H](+)) at m/z 426 and a corresponding product ion at m/z 174. Detection of ambroxol in human plasma was accurate and precise, with quantification limit at 0.2 ng/ml. This method has been successfully applied to a study of ambroxol in human specimens. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:209 / 216
页数:8
相关论文
共 50 条
  • [1] Simultaneous determination and pharmacokinetic study of roxithromycin and ambroxol hydrochloride in human plasma by LC-MS/MS
    Hang, Tai-jun
    Zhang, Meng
    Song, Min
    Shen, Jian-ping
    Zhang, Yin-di
    CLINICA CHIMICA ACTA, 2007, 382 (1-2) : 20 - 24
  • [2] Determination of Orelabrutinib in Human Plasma Using LC-MS/MS
    Zhao, Yang
    Guo, Yu-Jiao
    Chen, Xiang-Long
    Yang, Yan-Ling
    Ma, Hong
    Wang, Yong-Qing
    Sun, Lu-Ning
    THERAPEUTIC DRUG MONITORING, 2023, 45 (05) : 599 - 605
  • [3] A sensitive LC-MS/MS method for the simultaneous determination of amoxicillin and ambroxol in human plasma with segmental monitoring
    Dong, Xin
    Ding, Li
    Cao, Xiaomei
    Jiang, Liyuan
    Zhong, Shuisheng
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (04) : 520 - 526
  • [4] Simultaneous determination of amoxicillin and ambroxol in human plasma by LC-MS/MS: Validation and application to pharmacokinetic study
    Wen, Aidong
    Hang, Taijun
    Chen, Suning
    Wang, Zhirui
    Ding, Likun
    Tian, Yun
    Zhang, Meng
    Xu, Xinxin
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (03) : 829 - 834
  • [5] LC-MS–MS Determination of Pregabalin in Human Plasma
    Vikas V. Vaidya
    Santosh M. Yetal
    Shikha M. N. Roy
    Noel A. Gomes
    Santosh S. Joshi
    Chromatographia, 2007, 66 : 925 - 928
  • [6] Determination of pethidine in human plasma by LC-MS/MS
    Wang, Xianqin
    Xiang, Zheng
    Cai, Xiaojun
    Wu, Haiya
    Wang, Xuebao
    Li, Junwei
    Zhang, Meiling
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (07) : 833 - 837
  • [7] Determination of Ribavirin in Human Plasma by LC-MS/MS
    Ostervall, J.
    Ostlund, A.
    Pohanka, A.
    THERAPEUTIC DRUG MONITORING, 2013, 35 (05) : 725 - 725
  • [8] Determination of lercanidipine in human plasma by LC-MS/MS
    Jang, Moon-Sun
    La, Sookie
    Chang, Kyu Young
    Kang, Seung Woo
    Han, Sang Beom
    Lee, Kyung Ryul
    Lee, Hee Joo
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2008, 21 (01): : 34 - 40
  • [9] Sensitive determination of erythromycin in human plasma by LC-MS/MS
    Li, YX
    Neufeld, K
    Chastain, J
    Curtis, A
    Velagaleti, P
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 16 (06) : 961 - 970
  • [10] LC-MS/MS method for the determination of clodronate in human plasma
    Hasan, Mahmoud
    Schumacher, Gitta
    Seekamp, Anne
    Taedken, Tobias
    Siegmund, Werner
    Oswald, Stefan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 100 : 341 - 347