Field-emission-type x-ray source using carbon-nanofibers

被引:24
|
作者
Kita, S. [1 ]
Watanabe, Y. [1 ]
Ogawa, A. [1 ]
Ogura, K. [1 ]
Sakai, Y. [1 ]
Matsumoto, Y. [1 ]
Isokane, Y. [1 ]
Okuyama, F. [1 ]
Nakazato, T. [2 ]
Otsuka, T. [2 ]
机构
[1] Nagoya Inst Technol, Grad Sch Engn, Showa Ku, Nagoya, Aichi 4668555, Japan
[2] Nagoya City Univ, Dept Musculoskeletal Med, Grad Sch Med Sci, Mizuho Ku, Nagoya, Aichi 4678601, Japan
关键词
D O I
10.1063/1.2894730
中图分类号
O59 [应用物理学];
学科分类号
摘要
An x-ray irradiation system of field-emission type has been constructed using carbon-nanofibers (CNFs) grown on a palladium wire that is 50 mu m in diameter. The electron current emitted from the CNFs was approximately 1 mA and was stable within 10% for a long time t > 5000 h. The electrons passing through a slit in the gate electrode were accelerated to the desired energy, and were made to impinge on the metal target (Ti, Cu, Mo, and W) for generating x rays. The x-rays transmitted through Be-window were characterized using energy analyzers and a dosimeter. At an acceleration voltage of V(a)=50 kV, the energy spectra of the x-rays were exclusively composed of characteristic signals except for the Mo-target, and the dose rates of x-rays were D=2.5-14 Gy/min, depending on the target metals. This system also provides sharp x-ray images of both biological and nonbiological materials. (c) 2008 American Institute of Physics.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Field-emission electron source using carbon nanotubes for X-ray tubes
    Kim, Hyun Suk
    Duy, Dao Quang
    Kim, Jae Hoon
    Lee, Hyung Joo
    Yoon, Dang Mo
    Shin, Seok Seung
    Ha, Jung Woong
    Lee, Kang Jea
    Hwang, Yong Gyoo
    Lee, Choong Hun
    Park, Chong-Yun
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2008, 52 (04) : 1057 - 1060
  • [2] Multibeam X-Ray Source Array Based on Carbon Nanotube Field Emission
    Zhou, O.
    Lu, J.
    Calderon-Colon, X.
    Qian, X.
    Yang, G.
    Cao, G.
    Gidcumb, E.
    Tucker, A.
    Shan, J.
    Spronk, D.
    Sprenger, F.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [3] Dynamic radiography using a carbon-nanotube-based field-emission x-ray source
    Cheng, Y
    Zhang, J
    Lee, YZ
    Gao, B
    Dike, S
    Lin, W
    Lu, JP
    Zhou, O
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3264 - 3267
  • [4] Carbon nanotube based microfocus field emission x-ray source for microcomputed tomography
    Liu, Zejian
    Yang, Guang
    Lee, Yueh Z.
    Bordelon, David
    Lu, Jianping
    Zhou, Otto
    APPLIED PHYSICS LETTERS, 2006, 89 (10)
  • [5] A carbon nanotube field emission multipixel x-ray array source for microradiotherapy application
    Wang, Sigen
    Calderon, Xiomara
    Peng, Rui
    Schreiber, Eric C.
    Zhou, Otto
    Chang, Sha
    APPLIED PHYSICS LETTERS, 2011, 98 (21)
  • [6] Point x-ray source using graphite nanofibers and its application to x-ray radiography
    Matsumoto, T
    Mimura, H
    APPLIED PHYSICS LETTERS, 2003, 82 (10) : 1637 - 1639
  • [7] REPETITIONAL TYPE OF FIELD-EMISSION X-RAY SOURCE HAVING VARIABLE SPECTRA
    SATO, E
    ISOBE, H
    YANAGISAWA, T
    JOURNAL DE PHYSIQUE, 1987, 48 (C-6): : 121 - 126
  • [8] Development of microfocused x-ray source by using carbon nanotube field emitter
    Kawakita, K
    Hata, K
    Sato, H
    Saito, Y
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2006, 24 (02): : 950 - 952
  • [9] A Field-emission X-ray Source using an Anisotropically Focused Electron Beam
    Jung, Sunshin
    Han, Woo Kyung
    Kim, Daeho
    Chang, Won Suk
    Seol, Seung Kwon
    Bae, Woo Mi
    Byun, Gui Sob
    Park, Kyu Chang
    Ju, Byeong Kwon
    NANOTECHNOLOGY 2011: ADVANCED MATERIALS, CNTS, PARTICLES, FILMS AND COMPOSITES, NSTI-NANOTECH 2011, VOL 1, 2011, : 185 - 187
  • [10] Physiologically gated microbeam radiation, using a field emission x-ray source array
    Chtcheprov, Pavel
    Burk, Laurel
    Yuan, Hong
    Inscoe, Christina
    Ger, Rachel
    Hadsell, Michael
    Lu, Jianping
    Zhang, Lei
    Chang, Sha
    Zhou, Otto
    MEDICAL PHYSICS, 2014, 41 (08) : 88 - 95