Intrauterine device continuation rates and reasons for discontinuation in a Central European clinic with a high standard of care and ultrasound follow-up: a retrospective cohort study

被引:13
|
作者
Bachofner, Marion [1 ]
Blickenstorfer, Kerstin [1 ]
Hutmacher, Juliane [1 ]
Wehrle, Lucia [1 ]
Leeners, Brigitte [1 ]
Merki-Feld, Gabriele [1 ]
机构
[1] Univ Hosp Zurich, Dept Reprod Endocrinol, Frauenklin Str 10, CH-8091 Zurich, Switzerland
关键词
Contraception; copper-T IUD; discontinuation; dislocation; intrauterine device; levonorgestrel-releasing intrauterine system; long-acting reversible contraception; IUD; POSITION; PERFORMANCE; EXPULSION; INSERTION; FAILURE; PARITY; WOMEN; RISK; AGE;
D O I
10.1080/13625187.2018.1539164
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives: The aims of the study were to conduct an analysis of intrauterine device (IUD)-related outcomes, including continuation rates, reasons for discontinuation, rates of dislocation and risk factors for dislocation, in a clinical setting with regular ultrasound monitoring of the IUD position. Methods: A retrospective chart review was carried out of all IUD insertions over a period of 5 years. Results: A total of 755 IUDs were inserted over the study period. The overall observation time was 1572 woman-years. The removal rate was highest in the first year after insertion and did not differ between devices: the 52 mg levonorgestrel-releasing intrauterine system (LNG-IUS; 18%) and third generation copper-T (Cu-T) IUDs (20%). Most removals were related to dislocation; fewer dislocations were seen with the LNG-IUS compared with the Cu-T IUDs (p< .001). More removals of the LNG-IUS were carried out because of amenorrhoea, pain and hormone-related adverse events (20% of all removals). The discontinuation rate was higher in young women (age p< .03), demonstrating the limitations of long-acting reversible contraception in this age group. The dislocation rate for devices replaced after dislocation was 31% in women receiving a Cu-T IUD and 38% in women receiving an LNG-IUS. Conclusions: The first year after IUD insertion is crucial with regard to discontinuation. Most removals were attributed to dislocation and affected mainly younger women. Dislocations occurred more rarely in LNG-IUS users and the rate decreased over time. We recommend follow-up within the first 6-12 months, especially in young women. Structured counselling and consideration of risk factors for dislocation may reduce removal rates for adverse events and dislocations.
引用
收藏
页码:407 / 414
页数:8
相关论文
共 50 条
  • [1] Growth rates of malignant and benign thyroid nodules in an ultrasound follow-up study: a retrospective cohort study
    Michael Cordes
    Theresa Ida Götz
    Karen Horstrup
    Torsten Kuwert
    Christian Schmidkonz
    BMC Cancer, 19
  • [2] Growth rates of malignant and benign thyroid nodules in an ultrasound follow-up study: a retrospective cohort study
    Cordes, Michael
    Goetz, Theresa Ida
    Horstrup, Karen
    Kuwert, Torsten
    Schmidkonz, Christian
    BMC CANCER, 2019, 19 (01)
  • [3] Continuation rates and reasons for discontinuation of intra-uterine device in three provinces of Pakistan: results of a 24-month prospective client follow-up
    Hameed, Waqas
    Azmat, Syed Khurram
    Ishaque, Muhammad
    Hussain, Wajahat
    Munroe, Erik
    Mustafa, Ghulam
    Khan, Omar Farooq
    Abbas, Ghazunfer
    Ali, Safdar
    Asghar, Qaiser Jamshaid
    Ali, Sajid
    Bin Hamza, Hasan
    HEALTH RESEARCH POLICY AND SYSTEMS, 2015, 13
  • [4] Continuation rates and reasons for discontinuation of intra-uterine device in three provinces of Pakistan: results of a 24-month prospective client follow-up
    Waqas Hameed
    Syed Khurram Azmat
    Muhammad Ishaque
    Wajahat Hussain
    Erik Munroe
    Ghulam Mustafa
    Omar Farooq Khan
    Ghazunfer Abbas
    Safdar Ali
    Qaiser Jamshaid Asghar
    Sajid Ali
    Aftab Ahmed
    Hasan Bin Hamza
    Health Research Policy and Systems, 13
  • [5] Continuation Rates, Reasons for Removal and Safety of the Levonorgestrel Intrauterine Device in New Zealand Adolescents: A Nationwide Cohort Study
    Paterson, H.
    Woolrych, M. Harrison
    Ashton, J.
    DRUG SAFETY, 2011, 34 (10) : 998 - 998
  • [6] Intrauterine contraceptive device rupture. Follow-up of a retrospective cohort and clinical protocol. RUDIUS study
    Canovas, Esther
    Beric, Duska
    Jara, Rebeca
    Cazorla, Eduardo
    HELIYON, 2022, 8 (01)
  • [7] Predictors for Discontinuation of Intrauterine Devices That Underwent Ultrasound-Guided Placement in a Long-term Follow-up Cohort
    Balica, Adrian
    Dickson, Kaitlyn M.
    Egan, Susan
    Cabrera, Javier
    JOURNAL OF ULTRASOUND IN MEDICINE, 2021, 40 (10) : 2115 - 2122
  • [8] Loss to follow-up of patients in HIV care in Burundi: A retrospective cohort study
    Nshimirimana, Clement
    Ndayizeye, Aime
    Smekens, Tom
    Vuylsteke, Bea
    TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2022, 27 (06) : 574 - 582
  • [9] Characteristics of Changes in Caregiver Burden during Follow-up at a Memory Clinic: A Retrospective Cohort Study
    Takechi, Hajime
    Yoshino, Hiroshi
    Suzuki, Megumi
    Maeda, Akiko
    Suzumura, Shota
    Kamiya, Eiko
    JOURNAL OF ALZHEIMERS DISEASE REPORTS, 2024, 8 (01) : 151 - 162
  • [10] Profile of at-risk newborns attended by nurses in outpatient follow-up clinic: a retrospective cohort study
    Beleza, Ludmylla de Oliviera
    Ribeiro, Laiane Medeiros
    Parente Paula, Rayanne Augusta
    Del Alamo Guarda, Laise Escalianti
    Vieira, Gessica Borges
    Falcao Costae, Kassandra Silva
    REVISTA LATINO-AMERICANA DE ENFERMAGEM, 2019, 27