Decreasing driveline infections in patients supported on ventricular assist devices: a care pathway approach

被引:5
|
作者
Seretny, Julia [1 ]
Pidborochynski, Tara [2 ]
Buchholz, Holger [3 ]
Freed, Darren H. [3 ,4 ]
MacArthur, Roderick [3 ]
Dubyk, Nicole [5 ]
Cunliffe, Laura [5 ]
Zelaya, Osiris [5 ]
Conway, Jennifer [2 ,6 ]
机构
[1] Univ Alberta, Fac Nursing, Edmonton, AB, Canada
[2] Univ Alberta, Pediat Cardiol, Fac Med & Dent, Edmonton, AB, Canada
[3] Univ Alberta, Dept Surg, Fac Med & Dent, Edmonton, AB, Canada
[4] Stollery Childrens Hosp, Div Pediat Cardiac Surg, Edmonton, AB, Canada
[5] Mazankowski Alberta Heart Inst, Edmonton, AB, Canada
[6] Stollery Childrens Hosp, Div Pediat Cardiol, Edmonton, AB, Canada
关键词
Quality improvement; Statistical process control; Performance measures; Healthcare quality improvement; HOSPITAL READMISSIONS; EXIT-SITE; CIRCULATORY SUPPORT; INTERMACS DATABASE; IMPLANTATION; MULTICENTER; PREVENTION; MANAGEMENT; SYSTEM; IMPACT;
D O I
10.1136/bmjoq-2022-001815
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background Driveline infections (DLIs) are a common adverse event in patients on ventricular assist devices (VADs) with incidence ranging from 14% to 59%. DLIs have an impact on patients and the healthcare system with efforts to prevent DLIs being essential. Prior to our intervention, our program had no standard driveline management presurgery and postsurgery. The purpose of this Quality Improvement (QI) initiative was to reduce DLIs and related admissions among patients with VAD within the first year post implant. Methods In anticipation of the QI project, we undertook a review of the programs' current driveline management procedures and completed a survey with patients with VAD to identify current barriers to proper driveline management. Retrospective data were collected for a pre-QI intervention baseline comparison group, which included adult patients implanted with a durable VAD between 1 January 2017 and 31 July 2018. A three-pronged care pathway (CP) was initiated among patients implanted during August 2018 to July 2019. The CP included standardised intraoperative, postoperative and predischarge teaching initiatives and tracking. Using statistical process control methods, DLIs and readmissions in the first year post implant were compared between patients in the CP group and non-CP patients. P-charts were used to detect special cause variation. Results A higher proportion of CP group patients developed a DLI in the first year after implant (52% vs 32%). None developed a DLI during the index admission, which differed from the non-CP group and met criteria for special cause variation. There was a downward trend in cumulative DLI-related readmissions among CP group patients (55% vs 67%). There was no association between CP compliance and development of DLIs within 1 year post implant. Conclusion The CP did not lead to a reduction in the incidence of DLIs but there was a decrease in the proportion of patients with DLIs during their index admission and those readmitted for DLIs within 1 year post implant. This suggests that the CP played a role in decreasing the impact of DLIs in this patient population. However, given the short time period of follow-up longer follow-up will be required to look for sustained effects.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Decreasing Driveline Infections in Patients Supported on Ventricular Assist Devices: A Care Pathway Approach
    Seretny, J.
    Pidborochynski, T.
    Buchholz, H.
    Freed, D. H.
    MacArthur, R.
    Dubyk, N.
    Cunliffe, L.
    Zelaya, O.
    Conway, J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2021, 40 (04): : S452 - S453
  • [2] Avoiding Driveline Infections in Patients with Left Ventricular Assist Devices
    Tatooles, A. J.
    Gallagher, C. T.
    Pappas, P. S.
    Bresticker, M. A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2011, 30 (04): : S44 - S44
  • [3] Surgical Management of Driveline Infections in Patients with Ventricular Assist Devices
    Pieri, M.
    Scandroglio, A.
    Arlt, G.
    Falk, V.
    Krabatsch, T.
    Potapov, E.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S255 - S255
  • [4] Surgical management of driveline infections in patients with left ventricular assist devices
    Pieri, Marina
    Scandroglio, Anna Mara
    Mueller, Marcus
    Pergantis, Panagiotis
    Kretzschmar, Alexandra
    Kaufmann, Friedrich
    Falk, Volkmar
    Krabatsch, Thomas
    Arlt, Georg
    Potapov, Evgenij
    Kukucka, Marian
    JOURNAL OF CARDIAC SURGERY, 2016, 31 (12) : 765 - 771
  • [5] Reduction of Driveline Infections Through Doubled Driveline Tunneling of Left Ventricular Assist Devices
    Fleissner, Felix
    Avsar, Murat
    Malehsa, Doris
    Strueber, Martin
    Haverich, Axel
    Schmitto, Jan D.
    ARTIFICIAL ORGANS, 2013, 37 (01) : 102 - 107
  • [6] Left ventricular assist device driveline infections in three contemporary devices
    Schloeglhofer, Thomas
    Michalovics, Peter
    Riebandt, Julia
    Angleitner, Philipp
    Stoiber, Martin
    Laufer, Guenther
    Schima, Heinrich
    Wiedemann, Dominik
    Zimpfer, Daniel
    Moscato, Francesco
    ARTIFICIAL ORGANS, 2021, 45 (05) : 464 - 472
  • [7] Driveline Infections in Left Ventricular Assist Devices: Implications for Destination Therapy
    Sharma, Vikas
    Deo, Salil V.
    Stulak, John M.
    Durham, Lucian A., III
    Daly, Richard C.
    Park, Soon J.
    Baddour, Larry M.
    Mehra, Kashish
    Joyce, Lyle D.
    ANNALS OF THORACIC SURGERY, 2012, 94 (05): : 1381 - 1386
  • [8] Successful Cold Atmospheric Plasma Therapy of Driveline Infections in Patients with Left Ventricular Assist Devices
    Hilker, L.
    Sommer, K.
    von Woedtke, T.
    Weltmann, K.
    Kaminski, A.
    Reichenspurner, H.
    Barten, M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (04): : S489 - S490
  • [9] Cold Atmospheric Plasma for the Treatment of Superficial Driveline Infections in Patients with Left Ventricular Assist Devices
    Hilker, L.
    Sommer, K.
    von Woedtke, T.
    Weltmann, K.
    Wollert, H.
    Reichenspurner, H.
    Barten, M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (04): : S487 - S488
  • [10] An Analysis of Driveline Infections with Left Ventricular Assist Devices Utilizing Carbothane versus Pellethane Driveline Sheaths
    Ravichandran, A. K.
    Cowger, J. A.
    Feller, E. D.
    Mahr, C.
    Hiesinger, W.
    Klein, L.
    Jacoski, M. V.
    Lampert, B.
    Moazami, N.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2021, 40 (04): : S434 - S435