摘要
Electrical Capacitance Volume Tomography (ECVT) is one of three- dimensional image visualization method using capacitance effect. This paper describes a data acquisition system for 32-channel electrical capacitance volume tomography base on CMOS switch technology and charge- discharge system. results show the data acquisition system capable to measure of a novel capacitance with 0.21 fF to 0.42 fF resolution. this system are four frames per second for 32 channels.
引用
收藏
页码:326 / 329
页数:4
相关论文
共 50 条
  • [1] A 32-Channel High-Speed Simultaneously Sampling Data Acquisition System
    V. F. Gurko
    P. V. Zubarev
    A. N. Kvashnin
    D. V. Moiseev
    A. D. Khil'chenko
    V. A. Khil'chenko
    Instruments and Experimental Techniques, 2003, 46 : 608 - 612
  • [2] A 32-CHANNEL EVENT INTERFACE FOR A COMMERCIAL PORTABLE DATA ACQUISITION-SYSTEM
    MILBURN, P
    MOSHER, A
    MACLEOD, JA
    CANADIAN AGRICULTURAL ENGINEERING, 1992, 34 (03): : 291 - 293
  • [3] A 32-channel high-speed simultaneously sampling data acquisition system
    Gurko, VF
    Zubarev, PV
    Kvashnin, AN
    Moiseev, DV
    Khil'chenko, AD
    Khil'chenko, VA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2003, 46 (05) : 608 - 612
  • [4] Design and implementation of data acquisition system for the electrical capacitance tomography
    Chen, De-Yun
    Gao, Ming
    Li, Wei
    Wang, Li-Li
    Wang, Fei-Hu
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2013, 17 (05): : 87 - 92
  • [5] The study on image data acquisition system for electrical capacitance tomography system
    Li, Yan
    Jin, Tianbo
    Meng, Xiaoying
    Chen, Deyun
    Zhang, Liyong
    ICIEA 2007: 2ND IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-4, PROCEEDINGS, 2007, : 1635 - 1638
  • [6] A low-cost high performance capacitance data acquisition system for electrical capacitance tomography
    Hua, Y
    Xi, W
    Jing, G
    ICEMI'2003: PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOLS 1-3, 2003, : 2318 - 2322
  • [7] A 32-Channel Wireless System for Recording Gastric Electrical Activity
    Springston, Christopher S.
    Bao, Rui
    Farajidavar, Aydin
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 1971 - 1974
  • [8] A 32-Channel Wireless Configurable System for Electrical Stimulation of the Stomach
    Abukhalaf, Zaid
    Javan-Khoshkholgh, Amir
    Alrofati, Wahib
    Farajidavar, Aydin
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 4178 - 4181
  • [9] Architecture of EVT4 data acquisition system for electrical capacitance tomography
    Kryszyn, J.
    Wroblewski, P.
    Stosio, M.
    Wanta, D.
    Olszewski, T.
    Smolik, W. T.
    MEASUREMENT, 2017, 101 : 28 - 39
  • [10] Design of data acquisition system for 12-electrode electrical capacitance tomography
    Sheng, Liu
    Shen, Yijian
    Zheng, Guibin
    2007 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, VOLS I-V, CONFERENCE PROCEEDINGS, 2007, : 2293 - +