Diagnostic Accuracy for Per-Patient Polyp Detection of Second-Generation Capsule Endoscopy Compared to Colonoscopy: A Meta-Analysis of Multicenter Studies

被引:7
|
作者
Ali, Hassam [1 ]
Pamarthy, Rahul [1 ]
Sarfraz, Shiza [2 ]
Ali, Eslam [3 ]
机构
[1] East Carolina Univ, Vidant Med Ctr, Inter Med, Greenville, NC 27858 USA
[2] Bahawal Victoria Hosp, Quaid E Azam Med Coll, Anesthesiol, Bahawalpur, Pakistan
[3] Bahawal Victoria Hosp, Quaid E Azam Med Coll, Gastroenterol, Bahawalpur, Pakistan
关键词
cce; colon capsule endoscopy; colonoscopy; colon cancer prevention; colon cancer survillence; PERFORMANCE;
D O I
10.7759/cureus.17560
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Colon capsule endoscopy (CCE) or capsule colonoscopy can be used as colorectal cancer (CRC) screening option. We intended to analyze the concerning literature that compared second-generation CCE to standard colonoscopy for multicenter studies only. A literature search was performed in PubMed, Embase, and Web of Science. Study characteristics related to our research including sensitivity and specificity for per-patient polyps detection (size: >= 10 mm and >= 6 mm). Meta-analysis was performed using an open meta-analyst. Our research included five studies, involving a total of 1518 patients, with a total of 1305 analyzed patients. The adequate bowel preparation rate ranged from 70% to 90%. The rates of complete CCE transit fluctuated from 80% to 100%. Our meta-analysis illustrated that mean (95% confidence interval) per-patient sensitivity, specificity, and diagnostic odds ratio were: 0.86 (0.82-0.91) (p < 0.001), 0.88 (0.72-0.96) (p < 0.001), and 50.7 (18.5-138.9) (p < 0.001), respectively, for polyps >= 6 mm; and 0.86 (0.8-0.91) (p < 0.001), 0.96 (0.92-0.98) (p < 0.001), and 173.5 (98.4-305.8) (p < 0.001), respectively, for polyps >= 10 mm. We concluded that CCE had high sensitivity and specificity for per-patient polyps vs. standard colonoscopy. Nevertheless, the comparatively higher rate of unfinished CCEs limits the utilization of CCE for CRC screening.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Diagnostic accuracy of capsule endoscopy compared with colonoscopy for polyp detection: systematic review and meta-analyses
    Kjolhede, Tue
    Olholm, Anne Mette
    Kaalby, Lasse
    Kidholm, Kristian
    Qvist, Niels
    Baatrup, Gunnar
    ENDOSCOPY, 2021, 53 (07) : 713 - 721
  • [2] Second-generation colon capsule endoscopy compared with colonoscopy
    Spada, Cristiano
    Hassan, Cesare
    Munoz-Navas, Miguel
    Neuhaus, Horst
    Deviere, Jacques
    Fockens, Paul
    Coron, Emmanuel
    Gay, Gerard
    Toth, Ervin
    Riccioni, Maria Elena
    Carretero, Cristina
    Charton, Jean P.
    Van Gossum, Andre
    Wientjes, Carolien A.
    Sacher-Huvelin, Sylvie
    Delvaux, Michel
    Nemeth, Artur
    Petruzziello, Lucio
    Prieto de Frias, Cesar
    Mayershofer, Rupert
    Aminejab, Leila
    Dekker, Evelien
    Gahniche, Jean-Paul
    Frederic, Muriel
    Johansson, Gabriele Wurm
    Cesaro, Paola
    Costamagna, Guido
    GASTROINTESTINAL ENDOSCOPY, 2011, 74 (03) : 581 - 589
  • [3] Accuracy of Colon Capsule Endoscopy As Compared to Colonoscopy in the Detection of Colorectal Polyps: Systematic Review and Meta-Analysis
    Spada, Cristiano
    Hassan, Cesare
    Marmo, Riccardo
    Zullo, Angelo
    Cesaro, Paola
    Riccioni, Maria Elena
    Petruzziello, Lucio
    Costamagna, Guido
    GASTROINTESTINAL ENDOSCOPY, 2010, 71 (05) : AB244 - AB244
  • [4] ACCURACY OF COLON CAPSULE ENDOSCOPY AS COMPARED TO COLONOSCOPY IN THE DETECTION OF COLORECTAL POLYPS: SYSTEMATIC REVIEW AND META-ANALYSIS
    Spada, C.
    Hassan, C.
    Marmo, R.
    Zullo, A.
    Cesaro, P.
    Riccioni, M.
    Petruzziello, L.
    Costamagna, G.
    DIGESTIVE AND LIVER DISEASE, 2010, 42 : S65 - S66
  • [5] Prospective Multicenter Performance Evaluation of the Second-Generation Colon Capsule Compared with Colonoscopy
    Eliakim, R.
    Yassin, K.
    Niv, Y.
    Metzger, Y.
    Lachter, J.
    Ga, E.
    Sapoznikov, B.
    Konikoff, F.
    Leichtmann, G.
    Fireman, Z.
    Kopelman, Y.
    Adler, S. N.
    ENDOSKOPIE HEUTE, 2010, 23 (02) : 144 - 149
  • [6] Prospective multicenter performance evaluation of the second-generation colon capsule compared with colonoscopy
    Eliakim, R.
    Yassin, K.
    Niv, Y.
    Metzger, Y.
    Lachter, J.
    Gal, E.
    Sapoznikov, B.
    Konikoff, F.
    Leichtmann, G.
    Fireman, Z.
    Kopelman, Y.
    Adler, S. N.
    ENDOSCOPY, 2009, 41 (12) : 1026 - 1031
  • [7] Accuracy and safety of second-generation PillCam COLON capsule for colorectal polyp detection
    Spada, Cristiano
    De Vincentis, Fabio
    Cesaro, Paola
    Hassan, Cesare
    Riccioni, Maria Elena
    Grazioli, Leonardo Minelli
    Bolivar, Santiago
    Zurita, Andrade
    Costamagna, Guido
    THERAPEUTIC ADVANCES IN GASTROENTEROLOGY, 2012, 5 (03) : 173 - 178
  • [8] Diagnostic Accuracy of Wireless Capsule Endoscopy in Polyp Recognition Using Deep Learning: A Meta-Analysis
    Mi, Junjie
    Han, Xiaofang
    Wang, Rong
    Ma, Ruijun
    Zhao, Danyu
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2022, 2022 : 9338139
  • [9] Second-generation colon capsule endoscopy compared with colonoscopy (vol 74, pg 581, 2011)
    Amininejad, Leila
    GASTROINTESTINAL ENDOSCOPY, 2011, 74 (05) : 1174 - 1174
  • [10] Second-generation colon capsule endoscopy for detection of colorectal polyps: Systematic review and meta-analysis of clinical trials
    Moellers, Tobias
    Schwab, Matthias
    Gildein, Lisa
    Hoffmeister, Michael
    Albert, Joerg
    Brenner, Hermann
    Jaeger, Simon
    ENDOSCOPY INTERNATIONAL OPEN, 2021, 09 (04) : E562 - E571