Early Polyethylene Failure in a Modern Total Hip Prosthesis: A Note of Caution

被引:10
|
作者
Thomas, W. Christian [1 ]
Parvataneni, Hari K. [1 ]
Vlasak, Richard G. [1 ]
Gray, Chancellor F. [1 ]
机构
[1] Univ Florida, Dept Orthoped & Rehabil, Coll Med, Gainesville, FL 32607 USA
来源
JOURNAL OF ARTHROPLASTY | 2020年 / 35卷 / 05期
关键词
Exactech GXL; osteolysis; id-term failure; cross-linked polyethylene; polyethylene wear; ACETABULAR COMPONENT; ARTHROPLASTY; EPIDEMIOLOGY; WEAR; PCA;
D O I
10.1016/j.arth.2019.12.043
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Historically, there has been excellent survivorship of total hip arthroplasty with newer implants expected to outperform prior generations. Review of our institutional database identified problems with one particular cross-linked polyethylene liner in mid-term follow-up, which has not been reported in the literature. We report on the technical aspects of this liner, as well as the clinical and radiographic factors associated with early failure of this bearing in our practice. Methods: A retrospective review of our institutional database was performed from January 2009 to June 2019 of patients who presented with significant osteolysis in the setting of prior total hip arthroplasty with a contemporary polyethylene liner. Demographic and radiographic measures were collected for all patients. Results: Twelve patients were identified, with nine undergoing revision surgery. All patients demonstrated radiographic osteolysis at the time of revision surgery. The average time to diagnosis of failure was 55.9 months (range: 12-120 months). Average cup position preoperatively was 44 degrees inclination (range: 36-53 degrees) and 21 degrees anteversion (range: 10-34 degrees). Nine patients underwent revision of the acetabular component, with two also undergoing femoral component revision. The Manufacturer and User Facility Device Experience database revealed 22 reported cases of wear-related failure from 2009 to 2019. Conclusions: Considering that no identifiable risk factors related to patient demographics or implant position were identified, the Exactech Connexion GXL liner may be prone to a high rate of early failure from wear and severe secondary osteolysis. We recommend close surveillance of patients with this bearing surface. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:1297 / 1302
页数:6
相关论文
共 50 条
  • [1] Letter to the Editor on "Early Polyethylene Failure in a Modern Total Hip Prosthesis: A Note of Caution"
    Godoy-Monzon, Daniel
    Cid-Casteulani, Alberto
    Svarzchtein, Santiago
    JOURNAL OF ARTHROPLASTY, 2020, 35 (09): : 2688 - 2689
  • [2] Response to Letter to the Editor on "Early Polyethylene Failure in a Modern Total Hip Prosthesis: A Note of Caution"
    Thomas, William C.
    Parvataneni, Hari K.
    Vlasak, Richard G.
    Gray, Chancellor F.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (09): : 2689 - 2690
  • [3] WEAR OF POLYETHYLENE IN THE TOTAL HIP-PROSTHESIS
    ROSE, RM
    RADIN, EL
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1982, (170) : 107 - 115
  • [4] NOTE ON RINGS METHODS FOR TOTAL HIP PROSTHESIS
    CROZZOLI, N
    LASI, C
    MINERVA ORTOPEDICA, 1974, 25 (09): : 407 - 415
  • [5] Comparison of polyethylene wear in machined versus molded polyethylene in total hip prosthesis
    Courpied, JP
    Delhoume, J
    Kerboull, L
    Kerboull, M
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2000, 86 (01): : 10 - 14
  • [6] Abdominal cyst after early failure of polyethylene liner in total hip arthroplasty
    F. Benazzo
    M. Mosconi
    L. Piovani
    G. S. Fossati
    A. Sgarella
    Journal of Orthopaedics and Traumatology, 2002, 2 (2) : 105 - 109
  • [7] FAILURE PREDICTION OF THE TOTAL HIP-PROSTHESIS SYSTEM
    SIH, GC
    MATIC, P
    BERMAN, AT
    JOURNAL OF BIOMECHANICS, 1981, 14 (12) : 833 - 841
  • [8] Osteoporosis of the hip:: a note of caution
    Riancho, JA
    Gonzalo, C
    Zarrabeitia, T
    Macías, JG
    MEDICINA CLINICA, 1999, 112 (07): : 277 - 277
  • [9] Early failure in total hip arthroplasty
    Dobzyniak, Matthew
    Fehring, Thomas K.
    Odum, Susan
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (447) : 76 - 78
  • [10] TOTAL HIP PROSTHESIS
    MAEZAWA, H
    JOURNAL OF JAPAN SOCIETY OF LUBRICATION ENGINEERS, 1973, 18 (05): : 367 - 375