Development of transfer standard devices for ensuring the accurate calibration of ultrasonic physical therapy machines in clinical use.

被引:3
|
作者
Hekkenberg, RT [1 ]
Richards, A [1 ]
Beissner, K [1 ]
Zeqiri, B [1 ]
Prout, G [1 ]
Cantrall, C [1 ]
Bezemer, RA [1 ]
Koch, C [1 ]
Hodnett, M [1 ]
机构
[1] TNO, Prevent & Hlth, NL-2333 CK Leiden, Netherlands
关键词
D O I
10.1088/1742-6596/1/1/024
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Physical therapy ultrasound is widely applied to patients. However, many devices do not comply with the relevant standard stating that the actual power output shall be within +/- 20% of the device indication. Extreme cases have been reported: from delivering effectively no ultrasound or operating at maximum power at all powers indicated. This can potentially lead to patient injury as well as mistreatment. The present European (EC) project is an ongoing attempt to improve the quality of the treatment of patients being treated with ultrasonic physical-therapy. A Portable ultrasound Power Standard (PPS) is being developed and accurately calibrated. The PPS includes: Ultrasound transducers (including one exhibiting an unusual output) and a driver for the ultrasound transducers that has calibration and proficiency test functions. Also included with the PPS is a Cavitation Detector to determine the onset of cavitation occurring within the propagation medium. The PPS will be suitable for conducting in-the-field accreditation (proficiency testing and calibration). In order to be accredited it will be important to be able to show traceability of the calibration, the calibration process and qualification of testing staff. The clinical user will benefit from traceability because treatments will be performed more reliably.
引用
收藏
页码:99 / 104
页数:6
相关论文
共 3 条
  • [1] Development and Implementation of Calibration Measurement Methods for Physical Therapy Devices
    Sezdi, Mana
    Sari, Pelin
    Akan, Aydin
    TURKIYE FIZIKSEL TIP VE REHABILITASYON DERGISI-TURKISH JOURNAL OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 58 (01): : 47 - 51
  • [2] CLINICAL USE, PHYSICAL EVALUATION AND INTER-COMPARISON OF PERFORMANCE OF ULTRASONIC SCANNING MACHINES USED IN MEDICAL DIAGNOSIS
    MALLARD, JR
    CHRISTIE, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 176 - &
  • [3] Development of an instrument to measure the use of behaviors taught in the American Physical Therapy Association Clinical Instructor Education and Credentialing Program (APTA CIECP): A pilot study
    Bridges, Patricia H.
    Carter, Vincent
    Rehm, Stephanie
    Tintle, Sara Bowers
    Halperin, Rebecca
    Kniesly, Elizabeth
    Pelino, Soni
    WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2013, 44 (03): : 283 - 295