Real-time Ratiometric Fluorescent Assay for Alkaline Phosphatase Activity with Stimulus Responsive Infinite Coordination Polymer Nanoparticles

被引:227
|
作者
Deng, Jingjing [1 ]
Yu, Ping [1 ]
Wang, Yuexiang [1 ]
Mao, Lanqun [1 ]
机构
[1] Chinese Acad Sci, Inst Chem, Key Lab Analyt Chem Living Biosyst, Beijing Natl Lab Mol Sci, Beijing 100190, Peoples R China
关键词
TURN-ON ASSAY; COLORIMETRIC ASSAY; PROBE; STRATEGY; PYROPHOSPHATE; AGGREGATION; INHIBITION; CYSTEINE; SERUM; IONS;
D O I
10.1021/ac504773n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study demonstrates a novel ratiometric fluorescent method for real-time alkaline phosphatase (ALP) activity assay with stimulus responsive infinite coordination polymer (ICP) nanoparticles as the probe. The ICP nanoparticles used in this study are composed of two components; one is the supramolecular ICP network formed with guanine monophosphate (GMP) as the ligand and Tb3+ as the central metal ion, and the other is a fluorescent dye, i.e., 7-amino-4-methyl coumarin (coumarin) encapsulated into the ICP network. Upon being excited at 315 nm, the ICP network itself emits green fluorescence at 552 nm. Coumarin dye encapsulated in the ICP network emits weak fluorescence at 450 nm upon excitation at the same wavelength (315 nm), and this fluorescence emission becomes strong when the encapsulated dye is released from the network into the solution phase. Hence, we develop a ratiometric fluorescent assay based on the ALP-induced destruction of the supramolecular ICP network and the release of coumarin. This mechanism can be used for real-time ratiometric fluorescent monitoring of ALP activity by continuously measuring the ratio of fluorescent intensity at the wavelength of 552 nm (F-552) to that at 450 nm (F-450) (F-552/F-450) in the time-dependent fluorescent spectra of the coumarin@Tb-GMP suspension containing ALP with different activities. Under the experimental conditions employed here, the F-552/F-450 value is linear with the ALP activity within a range from 0.025 U/mL to 0.2 U/mL. The detection limit is down to 0.010 U/mL (S/N = 3). Moreover, the assay developed here is employed for ALP inhibitor evaluation. This study offers a simple yet sensitive method for real-time ALP activity assay.
引用
收藏
页码:3080 / 3086
页数:7
相关论文
共 50 条
  • [1] A real-time fluorescent assay for the detection of alkaline phosphatase activity based on carbon quantum dots
    Qian, Zhao Sheng
    Chai, Lu Jing
    Huang, Yuan Yuan
    Tang, Cong
    Shen, Jia Jia
    Chen, Jian Rong
    Feng, Hui
    BIOSENSORS & BIOELECTRONICS, 2015, 68 : 675 - 680
  • [2] Ratiometric fluorescent response of electrospun fibrous strips for real-time sensing of alkaline phosphatase in serum
    Zhao, Long
    Xie, Songzhi
    Song, Xiaojie
    Wei, Jiaojun
    Zhang, Zhao
    Li, Xiaohong
    BIOSENSORS & BIOELECTRONICS, 2017, 91 : 217 - 224
  • [3] Lanthanide-Free Infinite Coordination Polymer Nanoparticles for Real-Time Monitoring of Alkaline Phosphatase and Its Application for Digital Algal Bloom Detection
    Luo, Yuxin
    Li, Jiacheng
    Li, Yuanting
    Yang, Bowen
    Zhou, Tianshu
    Deng, Jingjing
    ACS APPLIED NANO MATERIALS, 2021, 4 (10) : 11134 - 11144
  • [4] Fluorescent enzyme-linked immunosorbent assay based on alkaline phosphatase-responsive coordination polymer composite
    Li, Shenghua
    Hu, Xing
    Li, Yong
    Tan, Hongliang
    MICROCHIMICA ACTA, 2021, 188 (08)
  • [5] Fluorescent enzyme-linked immunosorbent assay based on alkaline phosphatase-responsive coordination polymer composite
    Shenghua Li
    Xing Hu
    Yong Li
    Hongliang Tan
    Microchimica Acta, 2021, 188
  • [6] Novel ratiometric fluorescent probe for real-time detection of alkaline phosphatase and its application in living cells
    Huang, Xiaoqian
    Chen, Xiangzhu
    Chen, Shijun
    Zhang, Xueyan
    Wang, Lin
    Hou, Shicong
    Ma, Xiaodong
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2021, 260
  • [7] In situ reaction-based ratiometric fluorescent assay for alkaline phosphatase activity and bioimaging
    Ding, Yu
    Lin, Tianxia
    Shen, Jiwei
    Wei, Yinmao
    Wang, Chaozhan
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 282
  • [8] A carbon dot doped lanthanide coordination polymer nanocomposite as the ratiometric fluorescent probe for the sensitive detection of alkaline phosphatase activity
    Sun, Weidi
    Han, Xue
    Qu, Fengli
    Kong, Rong-Mei
    Zhao, Zilong
    ANALYST, 2021, 146 (09) : 2862 - 2870
  • [9] A high-sensitivity fluorescent probe with a self-immolative spacer for real-time ratiometric detection and imaging of alkaline phosphatase activity
    Zhang, Xueyan
    Chen, Xiangzhu
    Zhang, Yuanyuan
    Gao, Gui
    Huang, Xiaoqian
    Hou, Shicong
    Ma, Xiaodong
    NEW JOURNAL OF CHEMISTRY, 2019, 43 (30) : 11887 - 11892
  • [10] Real-Time Monitoring of Tyrosine Hydroxylase Activity with a Ratiometric Fluorescent Probe
    Yao, Jia-Yi
    Li, Lu
    Xu, Ji-Xuan
    Liu, Yan-Hong
    Shi, Jing
    Yu, Xiao-Qi
    Kong, Qing-Quan
    Li, Kun
    ANALYTICAL CHEMISTRY, 2024, 96 (18) : 7082 - 7090