Analysis of Dose Distribution and Risk of Pneumonitis in Stereotactic Body Radiation Therapy for Centrally Located Lung Tumors: A Comparison of Robotic Radiosurgery, Helical Tomotherapy and Volumetric Modulated Arc Therapy

被引:13
|
作者
Kannarunimit, Danita [1 ]
Descovich, Martina [2 ]
Garcia, Aaron [2 ]
Chen, Josephine [2 ]
Weinberg, Vivian [2 ]
Mcguinness, Christopher [2 ]
Pinnaduwage, Dilini [2 ]
Murnane, John [2 ]
Gottschalk, Alexander R. [2 ]
Yom, Sue S. [2 ]
机构
[1] King Chulalongkorn Univ Hosp, Dept Radiat Oncol, Bangkok, Thailand
[2] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
关键词
Central lung; SBRT; Robotic radiosurgery; Helical tomotherapy; VMAT; Pneumonitis; CYBERKNIFE RADIOSURGERY; TRACKING SYSTEM; MEGAVOLTAGE CT; RADIOTHERAPY; CANCER; RECONSTRUCTION; TOXICITY; ACCURACY; SBRT; VMAT;
D O I
10.7785/tcrt.2012.500394
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Stereotactic body radiation therapy (SBRT) to central lung tumors is associated with normal tissue toxicity. Highly conformal technologies may reduce the risk of complications. This study compares physical dose characteristics and anticipated risks of radiation pneumonitis (RP) among three SBRT modalities: robotic radiosurgery (RR), helical tomotherapy (HT) and volumetric modulated arc therapy (VMAT). Nine patients with central lung tumors. 5 cm were compared. RR, HT and VMAT plans were developed per RTOG 0831. Dosimetric comparisons included target coverage, conformity index, heterogeneity index, gradient index, maximal dose at 2 cm from target (D2cm), and dose-volume parameters for organs at risk (OARs). Efficiency endpoints included total beam-on time and monitor units. RP risk was derived from Lyman-Kutcher-Burman modeling on in-house software. The average GTV and PTV were 11.6 +/- 7.86 cm(3) and 36.8 +/- 18.1 cm(3). All techniques resulted in similar target coverage (p = 0.64) and dose conformity (p = 0.88). While RR had sharper fall-off gradient (p = 0.002) and lower D2 cm (p = 0.02), HT and VMAT produced greater homogeneity (p < 0.001) and delivery efficiency (p = 0.001). RP risk predicted from whole or contralateral lung volumes was less than 10%, but was 2-3 times higher using ipsilateral volumes. Using whole (p = 0.04, p = 0.02) or ipsilateral (p = 0.004, p = 0.0008) volumes, RR and VMAT had a lower risk of RP than HT. Using contralateral volumes, RR had the lowest RP risk (p = 0.0002, p = 0.0003 versus HT, VMAT). RR, HT and VMAT were able to provide clinically acceptable plans following the guidelines provided by RTOG 0813. All techniques provided similar coverage and conformity. RR seemed to produce a lower RP risk for a scenario of small PTV-OAR overlap and small PTV. VMAT and HT produced greater homogeneity, potentially desirable for a large PTV-OAR overlap. VMAT probably yields the lowest RP risk for a large PTV. Understanding subtle differences among these technologies may assist in situations where multiple choices of modality are available.
引用
收藏
页码:49 / 60
页数:12
相关论文
共 50 条
  • [1] Dosimetric Comparison of Volumetric Modulated Arc Therapy and Helical Tomotherapy for Spine Stereotactic Body Radiation Therapy
    Dandekar, V. K.
    Young, J. L.
    Turian, J.
    Diaz, A.
    Sher, D. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S725 - S725
  • [2] Comparison of Treatment Plans Using Robotic Radiosurgery With Fixed-Cone, Helical Tomotherapy, and Volumetric Modulated Arc Therapy With FFF Beam for Spine Stereotactic Body Radiation Therapy
    Kyu, L. Sang
    Kim, J. H.
    Kim, M. J.
    Woo, J. Y.
    Baek, J. G.
    Kim, S. Y.
    Cho, J. H.
    Chang, J. S.
    Koom, W. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E700 - E700
  • [3] A treatment-planning comparison of three beam arrangement strategies for stereotactic body radiation therapy for centrally located lung tumors using volumetric-modulated arc therapy
    Ishii, Kentaro
    Okada, Wataru
    Ogino, Ryo
    Kubo, Kazuki
    Kishimoto, Shun
    Nakahara, Ryuta
    Kawamorita, Ryu
    Ishii, Yoshie
    Tada, Takuhito
    Nakajima, Toshifumi
    JOURNAL OF RADIATION RESEARCH, 2016, 57 (03) : 273 - 279
  • [4] Stereotactic body radiation therapy for centrally-located lung tumors
    Shen, Ge
    Wang, Ying-Jie
    Shen, Wen-Jiang
    Zhou, Zhen-Shan
    Wang, Jun-Liang
    Sheng, Hong-Guo
    Dong, Da-Peng
    Zhou, Ming
    Yang, Gang
    Wang, Qin-Wen
    Zeng, Yanjun
    ONCOLOGY LETTERS, 2014, 7 (04) : 1292 - 1296
  • [5] Stereotactic Body Radiation Therapy (SBRT) for Low-Risk Prostate Cancer: A 3 Way Comparison Between Modulated Arc, Helical Tomotherapy, and Robotic Radiosurgery Plans
    Sen, A.
    Lollar, D.
    Falwell, W.
    Tremblay, J.
    Sakhakar, H.
    Sourivong, P.
    Payne, M.
    Taylor, O.
    Flynn, J.
    Kelly, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S385 - S385
  • [6] A comparison of robustness of volumetric modulated arc therapy and dynamic conformal arc therapy for lung stereotactic body radiation therapy
    Teague, Kathlina M.
    Miller, Daniel C.
    Nyamwanda, Jacqueline A.
    Prichard, Hugh A.
    Kirk, Michael C.
    MEDICAL DOSIMETRY, 2022, 47 (01) : 110 - 110
  • [7] Dosimetric Comparison of Stereotactic Body Radiation Therapy Plans With Volumetric Arc Therapy, Helical Tomotherapy, and Raystation for Liver Metastasis
    Onal, C.
    Efe, E.
    Yildirim, B. Akkus
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E177 - E178
  • [8] The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy
    Okutan, M.
    Franko, A.
    Koksal, C.
    Goksel, E. O.
    Karaman, S.
    Akpinar, Y. Emre
    Dagoglu, N.
    Demir, B.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (04): : 633 - 640
  • [9] Dosimetric comparison of volumetric modulated arc therapy with robotic stereotactic radiation therapy in hepatocellular carcinoma
    Paik, Eun Kyung
    Kim, Mi-Sook
    Choi, Chul Won
    Il Jang, Won
    Lee, Sung Hyun
    Choi, Sang Hyoun
    Kim, Kum Bae
    Lee, Dong Han
    RADIATION ONCOLOGY JOURNAL, 2015, 33 (03): : 233 - 241
  • [10] Stereotactic body radiation therapy for centrally located lung lesions
    Joyner, Melissa
    Salter, Bill J.
    Papanikolaou, Niko
    Fuss, Martin
    ACTA ONCOLOGICA, 2006, 45 (07) : 802 - 807