Sensitive and Rapid Detection of the New Delhi Metallo-Beta-Lactamase Gene by Loop-Mediated Isothermal Amplification

被引:56
|
作者
Liu, Wei [1 ]
Zou, Dayang [1 ]
Li, Yan [2 ]
Wang, Xuesong [1 ]
He, Xiang [1 ]
Wei, Xiao [1 ]
Shao, Changlin [1 ]
Li, Xuelian [1 ]
Shang, Wei [1 ]
Yu, Kaitao [2 ]
Liu, Dawei [1 ]
Li, Yunmei [1 ]
Guo, Jing [1 ]
Yin, Zhitao [1 ]
Yuan, Jing [1 ]
机构
[1] Acad Mil Med Sci, Inst Dis Control & Prevent, Beijing, Peoples R China
[2] Acad Mil Med Sci, Affiliated Hosp, Dept Resp Dis, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
KLEBSIELLA-PNEUMONIAE; ESCHERICHIA-COLI; INFECTION; IDENTIFICATION; CARBAPENEMASE; EMERGENCE; DIAGNOSIS; PAKISTAN; NDM-1;
D O I
10.1128/JCM.06647-11
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
New Delhi metallo-beta-lactamase 1 (NDM-1), which is associated with resistance to carbapenem, was first reported in 2008. A sensitive and rapid molecular assay to detect the plasmid bla(NDM-1) in clinical isolates is needed to control its spread. We describe a loop-mediated isothermal amplification (LAMP) assay for the rapid detection of bla(NDM-1) from pure culture and sputum, urine, and fecal samples. Eight sets of primers were designed to recognize six or eight distinct sequences on target bla(NDM-1), and one set was selected as the most appropriate set of primers for its rapid detection. The specificity and sensitivity of the primers in the LAMP reactions for bla(NDM-1) detection were determined. The sensitivity of the LAMP assay for bla(NDM-1) detection in sputum, urine, and fecal samples was also tested. Two methods, namely, monitoring of turbidity and addition of calcein to the reaction tube, were used to determine negative and positive results. The results showed that target DNA was amplified and visualized by the two detection methods within 70 min at an isothermal temperature of 65 degrees C. The sensitivity of LAMP, with a detection limit of 10.70 pg/mu l DNA, was 100-fold greater than that of PCR. Thirteen infection bacterial strains without bla(NDM-1) were selected for testing of specificity, and the results of the amplification were negative, which showed that the primers had good levels of specificity. The LAMP method reported here is demonstrated to be a potentially valuable means for the detection of bla(NDM-1) and rapid clinical diagnosis, being fast, simple, and low in cost.
引用
收藏
页码:1580 / 1585
页数:6
相关论文
共 50 条
  • [1] Rapid detection of the New Delhi metallo-b-lactamase 1 (NDM-1) gene by loop-mediated isothermal amplification (LAMP)
    Moreira, Mirna Giselle
    Barreto, Lidia Miranda
    dos Santos, Vera Lucia
    Monteiro, Andrea Souza
    Nobre, Vandack
    dos Santos, Simone Goncalves
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2018, 32 (04)
  • [2] Rapid and Sensitive Detection of Listeria ivanovii by Loop-Mediated Isothermal Amplification of the smcL Gene
    Wang, Yi
    Wang, Yan
    Xu, Huaqing
    Dai, Hang
    Meng, Shuang
    Ye, Changyun
    PLOS ONE, 2014, 9 (12):
  • [3] Rapid, Sensitive Detection of Bartonella quintana by Loop-Mediated Isothermal Amplification of the groEL Gene
    Hu, Shoukui
    Niu, Lina
    Luo, Lijuan
    Song, Xiuping
    Sun, Jimin
    Liu, Qiyong
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2016, 17 (12)
  • [4] Sensitive and Rapid Detection of ermB Gene in Clostridium difficile by Loop-Mediated Isothermal Amplification
    Lin, Minyi
    Liu, Wei
    Wang, Pu
    Zhou, Youlian
    Tan, Jiasheng
    Wu, Peiqun
    Mo, ZhiHui
    Zhang, Ting
    Xie, Shan
    Wang, Zhongqiu
    Fei, Jiaxi
    Yuan, Jing
    Chen, Ye
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2014, 109 : S113 - S113
  • [5] Rapid and Sensitive Detection of Plesiomonas shigelloides by Loop-Mediated Isothermal Amplification of the hugA Gene
    Meng, Shuang
    Xu, Jianguo
    Xiong, Yanwen
    Ye, Changyun
    PLOS ONE, 2012, 7 (10):
  • [6] Rapid and Sensitive Detection of Listeria monocytogenes by Loop-Mediated Isothermal Amplification
    Tang, Meng-Jun
    Zhou, Sheng
    Zhang, Xiao-Yan
    Pu, Jun-Hua
    Ge, Qing-Lian
    Tang, Xiu-Jun
    Gao, Yu-Shi
    CURRENT MICROBIOLOGY, 2011, 63 (06) : 511 - 516
  • [7] Rapid and Sensitive Detection of Listeria monocytogenes by Loop-Mediated Isothermal Amplification
    Meng-Jun Tang
    Sheng Zhou
    Xiao-Yan Zhang
    Jun-Hua Pu
    Qing-Lian Ge
    Xiu-Jun Tang
    Yu-Shi Gao
    Current Microbiology, 2011, 63
  • [8] Rapid and Sensitive Detection of Lophophora williamsii by Loop-Mediated Isothermal Amplification
    Sasaki, Yohei
    Fujimoto, Tsuguto
    Aragane, Masako
    Yasuda, Ichiro
    Nagumo, Seiji
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2009, 32 (05) : 887 - 891
  • [9] Sensitive and rapid detection of Zika virus by loop-mediated isothermal amplification
    Zhao, Jiangtao
    Feng, Ruo
    VIRUS GENES, 2019, 55 (01) : 43 - 50
  • [10] Sensitive and rapid detection of Zika virus by loop-mediated isothermal amplification
    Jiangtao Zhao
    Ruo Feng
    Virus Genes, 2019, 55 : 43 - 50