A patch-type flexible physiological monitor on a non-woven material

被引:0
|
作者
Chang, Wen-Yang
Chang, Jin-Sheng
Chu, Chun-Hsun
Ho, Tzong-Che
Lin, Yu-Cheng
机构
[1] Natl Cheng Kung Univ, Dept Engn Sci, Tainan 701, Taiwan
[2] Ind Technol Res Inst, Microsyst Technol Ctr, Tainan 709, Taiwan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The study reported is about an integrated wireless physiological monitor module of the flexible patch type, used on a non-woven material to package this module by a hot press process. The module can monitor the body temperature and heart rate. Experimental results showed that the specification and accuracy should be 25 - 40 degrees C +/- 0.5 degrees C and 50 - 200 bpm +/- 2 bpm. The main advantage of the module is that the postural change can be monitored. At the same time, it has also a good adhesion between substrate and components, without crack of conductor trace line after bending the module repeatedly. Thickness is about 2 turn. The aim of this study is to speed up the physiological technology and to create more efficiency by miniaturization. In addition, the acceptance level of wearing it is increased by the small and ergonomic design.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 50 条
  • [1] A patch-type flexible physiological monitor on a non-woven material
    Chang, Wen-Yang
    Chang, Jin-Sheng
    Chu, Chun-Hsun
    Ho, Tzong-Che
    Lin, Yu-Cheng
    ADVANCED ELECTRONIC PACKAGING, 2007, 968 : 35 - +
  • [2] A wireless patch-type physiological monitoring microsystem
    Ke, Ting-Chen
    Yang, Kuo-Yu
    2006 IEEE SENSORS, VOLS 1-3, 2006, : 1159 - +
  • [3] A patch-type wireless physiological monitoring microsystems
    Ke, T. C.
    Lin, W. S.
    Chang, W. Y.
    HEALTHCOM 2007: UBIQUITOUS HEALTHCARE IN AGING SOCIETIES, 2007, : 208 - +
  • [4] NON-WOVEN TETORON CLOTH FOR PATCH GRAFT ANGIOPLASTY
    UJIIE, H
    YAMAMOTO, Y
    ISHIKAWA, M
    AKABA, N
    YOHDA, T
    WATANUKI, T
    MATSUI, M
    HORIKOSHI, S
    MARUYAMA, K
    NAKAMURA, Y
    ARAI, T
    ARTIFICIAL ORGANS, 1981, 5 (03) : 334 - 334
  • [5] Multilayer Radar Absorbing Non-Woven Material
    Dedov, A. V.
    Nazarov, V. G.
    RADIOPHYSICS AND QUANTUM ELECTRONICS, 2016, 59 (01) : 43 - 47
  • [6] DEVELOPMENT OF WET PRODUCTION OF NON-WOVEN MATERIAL
    SCHMIDT, S
    ZELLSTOFF UND PAPIER, 1972, 21 (09): : 280 - &
  • [7] Multilayer Radar Absorbing Non-Woven Material
    A. V. Dedov
    V. G. Nazarov
    Radiophysics and Quantum Electronics, 2016, 59 : 43 - 47
  • [8] Development of a Patch-Type Flexible Oxygen Partial Pressure Sensor
    Katayama, Yuta
    Fujioka, Yuta
    Tsukada, Kosuke
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2020, 8 (08):
  • [9] The Acoustic Insulation Property of a New Non-Woven Material
    Chen, Jinjing
    Guo, Zheng
    ADVANCED ENGINEERING MATERIALS, PTS 1-3, 2011, 194-196 : 471 - 475
  • [10] ECONOMICS AND PROGNOSTS OF AMERICAN MARKETS FOR NON-WOVEN MATERIAL
    PIETTE