New discrimination algorithm for artificial γ radiation sources based on average energy deposition in plastic scintillators

被引:1
|
作者
Hu, Bin [1 ]
Ye, Hao [1 ]
Li, Fu-Long [2 ]
Tian, Xing Yu [1 ]
Song, Le-Tian [1 ]
Zhang, Yan [1 ]
Zhang, Xiong-Jie [1 ]
Wang, Ren-Bo [1 ]
Tang, Bin [1 ]
机构
[1] East China Univ Technol, Minist Educ, Engn Res Ctr Nucl Technol Applicat, Nanchang 330013, Jiangxi, Peoples R China
[2] China Gen Nucl Power Grp Begood Technol Ltd Liabi, Nanchang 330000, Jiangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Average energy algorithm; Plastic scintillator; NORM; Artificial radiation sources; IDENTIFICATION ALGORITHM; WEIGHTED ALGORITHM;
D O I
10.1016/j.nima.2021.165573
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Plastic scintillators are characterized with high detection efficiency, high response speeds, uneven optical efficiency distributions, and poor energy resolution. In this work, we developed a new discrimination algorithm, namely, the average energy (AE) algorithm, for artificial y radiation sources and implemented it in a hand-held plastic scintillator detector. The algorithm provided excellent discrimination capability of naturally occurring radiation materials (NORM) and artificial radiation Sources. The energy deposited by all radiation sources in small plastic scintillators, was simulated and analyzed using the Monte Carlo method. And all those radiation sources are categorized by the International Atomic Energy Agency. A plastic scintillator detector system was then constructed for proof of concept using Am-241, Cs-137, Co-60, radium-bearing ore, and thorium ore. A large-sized plastic scintillator detector was used for comparison, and the correctness of the AE algorithm was verified. The AEs of the NORM region ranged from 631.5 +/- 13.3 keV to 783.6 +/- 17.2 keV and 1173.6 keV or more, and the collection time of a single measurement was less than 3 s (5214 photons). Results showed that the AE algorithm could quickly and accurately identify gamma artificial radiation sources from the background and NORM. The AE algorithm should always be used in conjunction with the energy window algorithm to avoid misjudgments.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Detection and discrimination of α- and β-radiation with plastic scintillators based on pulse shape discrimination
    Zhang, Z. H.
    Zhang, Y. F.
    Hu, C. Y.
    Feng, S.
    Zhu, J. J.
    Liao, B.
    Liu, D. K.
    Zhou, Q.
    Wang, H. R.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (04):
  • [2] Optimization for energy response characteristics of plastic scintillators based on genetic algorithm
    Li, Zhongliang
    Pan, Ziheng
    Hu, Guang
    Sun, Weiqiang
    Hu, Huasi
    AIP ADVANCES, 2022, 12 (11)
  • [3] Dynamic radionuclide identification using energy weighted algorithm with commercialized radiation portal monitor based on plastic scintillators
    Lee, Hyun Cheol
    Choi, Hyun Joon
    Koo, Bon Tack
    Choi, Chang-Il
    Park, Chang Su
    Kim, Hong-Suk
    Min, Chul Hee
    RADIATION PHYSICS AND CHEMISTRY, 2020, 170
  • [4] New results on radiation damage studies of plastic scintillators
    Nucl Instrum Methods Phys Res Sect A, 1 (55):
  • [5] New results on radiation damage studies of plastic scintillators
    Vasilchenko, VG
    Lapshin, VG
    Peresypkin, AI
    Konstantinchenko, AA
    Pyshchev, AI
    Shershukov, VM
    Semenov, BV
    Solovev, AS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 369 (01): : 55 - 61
  • [6] A new type of plastic scintillators with excellent radiation resistance
    Bol'bit, NM
    Taraban, VB
    Shelukhov, IP
    Klinshpont, ER
    Milinchuk, VK
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2000, 43 (04) : 460 - 464
  • [7] A new type of plastic scintillators with excellent radiation resistance
    N. M. Bol’bit
    V. B. Taraban
    I. P. Shelukhov
    E. R. Klinshpont
    V. K. Milinchuk
    Instruments and Experimental Techniques, 2000, 43 : 460 - 464
  • [8] Radioisotope identification using an energy-weighted algorithm with a proof-of-principle radiation portal monitor based on plastic scintillators
    Lee, Hyun Cheol
    Shin, Wook-geun
    Choi, Hyun Joon
    Choi, Chang-Il
    Park, Chang Su
    Kim, Hong-Suk
    Min, Chul Hee
    APPLIED RADIATION AND ISOTOPES, 2020, 156 (156)
  • [9] Radiation Hard Plastic Scintillators for a New Generation of Particle Detectors
    Dettmann, M.
    Herrig, V.
    Maldonis, J.
    Neuhaus, J.
    Shrestha, D.
    Rajbhandari, P.
    Thune, Z.
    Been, M.
    Martinez-Szewczyk, M.
    Khristenko, V.
    Onel, Y.
    Akgun, U.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [10] MONTE-CARLO CALCULATION OF RADIATION ENERGY ABSORBED IN PLASTIC SCINTILLATORS
    MAINARDI, RT
    BONZI, EV
    APPLIED RADIATION AND ISOTOPES, 1995, 46 (6-7) : 499 - 500