Minimally invasive plate osteosynthesis in humerus nonunion after intramedullary nailing

被引:10
|
作者
Allende, Christian [1 ]
Vanoli, Fernando [1 ]
Gentile, Luciano [1 ]
Gutierrez, Natalia [1 ]
机构
[1] Sanatorio Allende, Inst Allende Cirugia Reconstruct, Hipolito Yrigoyen 384, RA-5000 Cordoba, Argentina
关键词
Humerus diaphyseal nonunion; Failed intramedullary nailing; Minimally invasive plating; SHAFT FRACTURES; MANAGEMENT; FIXATION; FAILURE;
D O I
10.1007/s00264-018-3911-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionThe purpose of this study was to evaluate the results achieved after the use of lateral minimally invasive plate osteosynthesis (MIPO) in oligotrophic humerus nonunions resulting from failed intramedullary nailing (IM).MethodWe evaluated nine patients with humerus nonunion after failed locked intramedullary nailing, all treated using 3.5-mm locked compression plates (LCP) placed through lateral minimally invasive approaches, between 2010 and 2016. Patient's age averaged 39.7years. All nonunions were diaphyseal and oligotrophic. All nonunions had previous surgical treatment with static locked nails (seven antegrade and two retrograde). The IM nails were all well inserted in the humerus (none of them protruded or had rotator cuff lesions associated). Pre-operative Disabilities of the Arm, Shoulder and Hand (DASH) score averaged 25.5 points. Pre-operative Constant's score averaged 80.2. Pre-operative visual analog scale of pain averaged 2.4 points.ResultsFollow-up averaged 17.7months. Time between initial surgery and revision procedure averaged 11.7months. Union was achieved in all cases, after an average of 4.8months. DASH score at last follow-up averaged 5.1 points, and final Constant's score averaged 93.7 points. The analog scale of pain averaged 0.7 points. Time from definitive surgery to work return averaged 3.9months. Long 3.5-mm LCPs were used (plate length averaged 16.9 screw holes). In two cases, a third 4-cm incision at the nonunion site was performed and cancellous autologous iliac crest bone graft was associated.ConclusionIn our series of nine patients, we achieved union and good objective and subjective results, with high patient satisfaction, using a lateral MIPO technique and placing long 3.5-mm LCPs in selected oligotrophic humerus nonunions after failed IM nailing.
引用
收藏
页码:2685 / 2689
页数:5
相关论文
共 50 条
  • [1] Minimally invasive plate osteosynthesis in humerus nonunion after intramedullary nailing
    Christian Allende
    Fernando Vanoli
    Luciano Gentile
    Natalia Gutierrez
    International Orthopaedics, 2018, 42 : 2685 - 2689
  • [2] Intramedullary nailing of the humerus as an alternative to conservative therapy and plate osteosynthesis
    Kessler, SB
    NastKolb, D
    Brunner, U
    Wischhofer, E
    ORTHOPADE, 1996, 25 (03): : 216 - 222
  • [3] Comparison between antegrade intramedullary nailing (IMN), open reduction plate osteosynthesis (ORPO) and minimally invasive plate osteosynthesis (MIPO) in treatment of humerus diaphyseal fractures
    Kulkarni, Vidisha Sunil
    Kulkarni, Madhura Sujay
    Kulkarni, Govind Shivram
    Goyal, Vaibhav
    Kulkarni, Milind Govind
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 : S8 - S13
  • [4] Comparison between intramedullary nailing and minimally invasive plate osteosynthesis for tibial shaft fractures
    Kang, Hyunseong
    Rho, Joseph Y.
    Song, Jung-Kook
    Choi, Jaewon
    Kwon, Yong Suk
    Choi, Sungwook
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (04): : 1011 - 1016
  • [5] Minimally invasive plate osteosynthesis of the proximal humerus
    Acklin, Y. P.
    Sommer, C.
    TRAUMA UND BERUFSKRANKHEIT, 2011, 13 (04) : 234 - 238
  • [6] Minimally invasive plate osteosynthesis for humerus diaphyseal fractures
    Shetty, M. Shantharam
    Kumar, M. Ajith
    Sujay, K. T.
    Kini, Abhishek R.
    Kiran, Kanthi G.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2011, 45 (06) : 520 - 526
  • [7] Minimally invasive plate osteosynthesis for humerus diaphyseal fractures
    M. Shantharam Shetty
    M. Ajith Kumar
    K. T. Sujay
    Abhishek R. Kini
    G. Kiran Kanthi
    Indian Journal of Orthopaedics, 2011, 45 : 520 - 526
  • [8] Minimally Invasive Plate Osteosynthesis (MIPO) for Treatment of Delayed or Nonunion of the Humerus Shaft Fracture: A New Technique
    Okhovatpour, Mohammad Ali
    Yousefi-Hajivand, Esmaeel
    Khojasteh, Arash
    Tabrizi, Ali
    Mirahmadi, Alireza
    TRAUMA MONTHLY, 2022, 27 (02) : 445 - 452
  • [9] Minimally invasive plate osteosynthesis (MIPO) in the treatment of the femoral shaft fracture where intramedullary nailing is not indicated
    Apivatthakakul, T.
    Chiewcharntanakit, S.
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (04) : 1119 - 1126
  • [10] Minimally invasive plate osteosynthesis or conventional intramedullary nailing for distal tibial fractures A cohort study protocol
    Song, Xin
    Huang, Xun
    Yakufu, Maihemuti
    Yan, Bin
    Feng, Chencheng
    MEDICINE, 2020, 99 (33) : E21779