Automatic local resolution-based sharpening of cryo-EM maps

被引:85
|
作者
Ramirez-Aportela, Erney [1 ]
Luis Vilas, Jose [1 ]
Glukhova, Alisa [2 ]
Melero, Roberto [1 ]
Conesa, Pablo [1 ]
Martinez, Marta [1 ]
Maluenda, David [1 ]
Mota, Javier [1 ]
Jimenez, Amaya [1 ]
Vargas, Javier [3 ]
Marabini, Roberto [4 ]
Sexton, Patrick M. [2 ,5 ]
Maria Carazo, Jose [1 ]
Sorzano, Carlos Oscar S. [1 ,6 ]
机构
[1] Natl Ctr Biotechnol CSIC, Biocomp Unit, Darwin 3,Campus Univ Autonoma Madrid, Madrid 28049, Spain
[2] Monash Inst Pharmaceut Sci, Drug Discovery Biol, Parkville, Vic 3052, Australia
[3] McGill Univ, Dept Anat & Cell Biol, 3640 Rue Univ, Montreal, PQ H3A 0C7, Canada
[4] Univ Autonoma Madrid, Campus Univ Autonoma Madrid, E-28049 Madrid, Spain
[5] Fudan Univ, Sch Pharm, Shanghai 201203, Peoples R China
[6] Univ CEU San Pablo, Campus Urb Monteprincipe, Madrid 28668, Spain
基金
欧盟地平线“2020”;
关键词
ELECTRON; VALIDATION; CRYSTAL; MODEL;
D O I
10.1093/bioinformatics/btz671
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Motivation: Recent technological advances and computational developments have allowed the reconstruction of Cryo-Electron Microscopy (cryo-EM) maps at near-atomic resolution. On a typical workflow and once the cryo-EM map has been calculated, a sharpening process is usually performed to enhance map visualization, a step that has proven very important in the key task of structural modeling. However, sharpening approaches, in general, neglects the local quality of the map, which is clearly suboptimal. Results: Here, a new method for local sharpening of cryo-EM density maps is proposed. The algorithm, named LocalDeblur, is based on a local resolution-guided Wiener restoration approach of the original map. The method is fully automatic and, from the user point of view, virtually parameter-free, without requiring either a starting model or introducing any additional structure factor correction or boosting. Results clearly show a significant impact on map interpretability, greatly helping modeling. In particular, this local sharpening approach is especially suitable for maps that present a broad resolution range, as is often the case for membrane proteins or macromolecules with high flexibility, all of them otherwise very suitable and interesting specimens for cryo-EM. To our knowledge, and leaving out the use of local filters, it represents the first application of local resolution in cryo-EM sharpening.
引用
收藏
页码:765 / 772
页数:8
相关论文
共 50 条
  • [1] Model-based local density sharpening of cryo-EM maps
    Jakobi, Arjen J.
    Wilmanns, Matthias
    Sachse, Carsten
    ELIFE, 2017, 6
  • [3] Quantifying the local resolution of cryo-EM density maps
    Kucukelbir A.
    Sigworth F.J.
    Tagare H.D.
    Nature Methods, 2014, 11 (1) : 63 - 65
  • [4] Measuring local-directional resolution and local anisotropy in cryo-EM maps
    Jose Luis Vilas
    Hemant D. Tagare
    Javier Vargas
    Jose Maria Carazo
    Carlos Oscar S. Sorzano
    Nature Communications, 11
  • [5] Measuring local-directional resolution and local anisotropy in cryo-EM maps
    Vilas, Jose Luis
    Tagare, Hemant D.
    Vargas, Javier
    Maria Carazo, Jose
    Sorzano, Carlos Oscar S.
    NATURE COMMUNICATIONS, 2020, 11 (01)
  • [6] Cryo-EM density maps adjustment for subtraction, consensus and sharpening
    Gimenez, E. Fernandez
    Martinez, M.
    Sanchez-Garcia, R.
    Marabini, R.
    Ramirez-Aportela, E.
    Conesa, P.
    Carazo, J. M.
    Sorzano, C. O. S.
    JOURNAL OF STRUCTURAL BIOLOGY, 2021, 213 (04)
  • [7] CryoRes: Local Resolution Estimation of Cryo-EM Density Maps by Deep Learning
    Dai, Muzhi
    Dong, Zhuoer
    Xu, Kui
    Zhang, Qiangfeng Cliff
    JOURNAL OF MOLECULAR BIOLOGY, 2023, 435 (09)
  • [8] ANALYSES OF SUBNANOMETER RESOLUTION CRYO-EM DENSITY MAPS
    Baker, Matthew L.
    Baker, Mariah R.
    Hryc, Corey F.
    DiMaio, Frank
    METHODS IN ENZYMOLOGY, VOL 483: CRYO-EM, PART C: ANALYSES, INTERPRETATION, AND CASE STUDIES, 2010, 483 : 1 - 29
  • [9] Quality vs. Resolution in Cryo-EM Maps
    Stagg, Scott M.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2019, 75 : A412 - A412
  • [10] Automatic Detection of Beta-barrel from Medium Resolution Cryo-EM Density Maps
    Si, Dong
    PROCEEDINGS OF THE 7TH ACM INTERNATIONAL CONFERENCE ON BIOINFORMATICS, COMPUTATIONAL BIOLOGY, AND HEALTH INFORMATICS, 2016, : 156 - 164