Predictors of survival in cardiogenic shock (CS) treated with intra-aortic balloon pump (IABP) are not clearly understood. In this retrospective study, we sought to evaluate patient characteristics and impact of timing of IABP in treatment of CS. Patients presenting to the Yale New Haven Hospital in CS who received IABP between February 2013 and April 2017 were included in the study. We assessed baseline characteristics and clinical predictors of 30-day mortality. Hundred ninety-three (n = 193) patients were included in this study. Mean age was 68.8 +/- 14.5 years. Thirty percent (30%) were women, 38% had cardiac arrest, and left ventricular ejection fraction was 33.7 +/- 14.9%. Overall 30-day mortality was 36%. Thirty-day mortality was 24% when IABP was placed within less than 1 hour of onset of CS versus 49% when implanted >= 1 hour after recognition of CS (p = 0.001). Mortality was 18%, 21%, 36%, and 74% for patient requiring 0, 1, 2, and 3 or more inotropes after IABP placement (p < 0.001). In multivariate analysis, advancing age, cardiac arrest on presentation, time to IABP implantation, and number of inotropes needed after IABP implantation predicted 30-day mortality. In the 193 patients, 134 (69.4%) presented with CS from ACS and 59 (30.6%) with CS from non-ACS-related causes. No difference in mortality was noted between the ACS and non-ACS groups 34.3% versus 40.7% (p = 0.39). In conclusion, early use of IABP in CS was associated with significant improvement in 30-day mortality regardless of the etiology of CS. Continued need for significant inotropic support after IABP is associated with worse prognosis and maybe used as an indicator for need to escalate to higher levels of support. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:750 / 756
页数:7
相关论文
共 50 条
  • [1] Intra-Aortic Balloon Pump (IABP) in cardiogenic shock
    Fuernau, Georg
    Thiele, Holger
    CURRENT OPINION IN CRITICAL CARE, 2013, 19 (05) : 404 - 409
  • [2] Intra-Aortic Balloon Pump during Cardiogenic Shock
    Brechot, N.
    Demondion, P.
    Lebreton, G.
    Santi, F.
    Leprince, P.
    Combes, A.
    REANIMATION, 2016, 25 (02): : 178 - 186
  • [3] Evolution in the use of intra-aortic balloon pump in patients with cardiogenic shock
    Xavier Fontes, A.
    Montenegro Sa, F.
    Passos Silva, M.
    Caeiro, D.
    Dias, A.
    Santos, L.
    Rodrigues, J. A.
    Tavares, A.
    Braga, P.
    EUROPEAN HEART JOURNAL, 2018, 39 : 962 - 963
  • [4] Usefulness of Intra-Aortic Balloon Pump Counterpulsation in Patients With Cardiogenic Shock from Acute Myocardial Infarction
    Cheng, Jin M.
    Valk, Suzanne D. A.
    den Uil, Corstiaan A.
    van der Ent, Martin
    Lagrand, Wim K.
    van de Sande, Meike
    von Domburg, Ron T.
    Simoons, Maarten L.
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (03): : 327 - 332
  • [5] INTRA-AORTIC BALLOON PUMP IN PATIENTS WITH MYOCARDIAL INFARCTION AND CARDIOGENIC SHOCK OF STAGES A AND B
    Vyshlov, E. V.
    Panteleev, O. O.
    Ryabov, V. V.
    KARDIOLOGIYA, 2022, 62 (07) : 67 - 72
  • [6] Intra-Aortic Balloon Pump-Supported Coronary Angioplasty in Cardiogenic Shock Patients
    Shah, Jay
    Dani, Sameer
    Prajapati, Jayesh
    Jain, Sharad
    Joshi, Hadit
    Sharma, Kamal
    Shukla, Anand
    Thakkar, Bhavesh
    Shah, Hitesh
    Madan, Tarun
    Trivedi, Rutwik
    Kharche, Milind
    Poptani, Vishal
    Thanvi, Sunil
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (9A): : 91B - 91B
  • [7] Use of intra-aortic balloon pumps for patients with cardiogenic shock
    Zeymer, U.
    Thiele, H.
    Zahn, R.
    NOTFALL & RETTUNGSMEDIZIN, 2011, 14 (08): : 624 - 629
  • [8] Usefulness of Intra-aortic Balloon Pump Counterpulsation
    van Nunen, Lokien X.
    Noc, Marko
    Kapur, Navin K.
    Patel, Manesh R.
    Perera, Divaka
    Pijls, Nico H. J.
    AMERICAN JOURNAL OF CARDIOLOGY, 2016, 117 (03): : 469 - 476
  • [9] Intra-aortic balloon pump in cardiogenic shock: A propensity score matching analysis
    Yuan, Sheng
    He, Jining
    Cai, Zhongxing
    Zhang, Rui
    Song, Chenxi
    Qiao, Zheng
    Song, Weihua
    Feng, Lei
    Dou, Kefei
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 99 : 1456 - 1464
  • [10] Influence of intra-aortic balloon pump on mortality as a function of cardiogenic shock severity
    Jentzer, Jacob C.
    van Diepen, Sean
    Henry, Timothy D.
    Baran, David A.
    Barsness, Gregory W.
    Holmes, David R., Jr.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 99 (02) : 293 - 304