摘要
This paper describes the transient response of an automatic gain control (AGC) with multiple thresholds for intensity in an image-intensified camera. Similar examples have flown in intensified-video systems used in satellites. This paper completes the development of a stable AGC with an improved transient response over the system described in a previous work. The improved transient response uses the integrated scene brightness at various intensity thresholds.
引用
收藏
页码:1926 / 1933
页数:8
相关论文
共 50 条
  • [1] Automatic gain control for image-intensified camera
    Fowler, KR
    IMTC/O3: PROCEEDINGS OF THE 20TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1 AND 2, 2003, : 535 - 540
  • [2] Automatic gain control for image-intensified camera
    Fowler, KR
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2004, 53 (04) : 1057 - 1064
  • [3] LOW-INTENSITY BEAM MONITORING WITH AN IMAGE-INTENSIFIED SCINTILLATOR DETECTOR
    KANSTEIN, LL
    MORGADO, RE
    NORGREN, DU
    SORENSEN, RW
    NUCLEAR INSTRUMENTS & METHODS, 1974, 118 (02): : 483 - 485
  • [4] The automatic image analysis of red blood cell deformability and blood flow in microchannels with an image-intensified high-speed video camera system
    Shimizu, T
    Sekizuka, E
    Oshio, C
    Tsukada, K
    Nagai, T
    Hokari, R
    Minamitani, H
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 914 - 915
  • [5] FABRY-PEROT INTERFEROMETRY USING AN IMAGE-INTENSIFIED ROTATING-MIRROR STREAK CAMERA
    SEITZ, WL
    STACY, HL
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 427 : 186 - 192
  • [6] BARBOTAGE OF SHOULDER WITH IMAGE-INTENSIFIED FLUOROSCOPIC CONTROL OF NEEDLE PLACEMENT FOR CALCIFIC TENDINITIS
    COMFORT, TH
    ARAFILES, RP
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1978, (135) : 171 - 178
  • [7] Measurement of RBC velocities in the rat pial arteries with an image-intensified high-speed video camera system
    Ishikawa, M
    Sekizuka, E
    Shimizu, K
    Yamaguchi, N
    Kawase, T
    MICROVASCULAR RESEARCH, 1998, 56 (03) : 166 - 172
  • [8] Transient gain control in EDFA's by dual-cavity optical automatic gain control
    Liu, YQ
    Krol, MF
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1999, 11 (11) : 1381 - 1383
  • [9] CALCULATION OF TRANSIENT PROCESSES IN THE AUTOMATIC GAIN-CONTROL SYSTEMS
    GOSTEV, VI
    FENEV, DV
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII RADIOELEKTRONIKA, 1980, 23 (07): : 81 - 83
  • [10] Modeling of a Multiple Digital Automatic Gain Control System
    王经典
    陆秀洪
    张利
    Tsinghua Science and Technology, 2008, (06) : 807 - 811