Respiratory gated radiation therapy directly using patient's fluoroscopic images instead of external or internal markers

被引:0
|
作者
Guan, H
Yan, H
Yin, F
Kim, J
Keall, P
Vedam, S
Movsas, B
机构
[1] Henry Ford Hosp Syst, Detroit, MI USA
[2] Duke Univ, Durham, NC USA
[3] Virginia Commonwealth Univ, Richmond, VA USA
关键词
D O I
10.1118/1.1997616
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a respiratory gated radiation therapy (RGRT) technique by directly matching the patient's anatomical structures acquired during the imaging cycles to that in a reference image. Method and Materials: Studies showed that the external markers and the internal treatment volume are not always well correlated during the RGRT. Here we propose to measure the correlations of a reference image to the fluoroscopic images acquired during the breathing cycles. Such correlation measurement can be the surrogate for the external markers. A threshold of the correlation can be used to trigger the linear accelerator (Linac) for RGRT. With the capability of acquiring fluoroscopic images from the on‐board imaging (OBI) device developed by Varian, this approach becomes available. In this study, we measured the correlation coefficient (cc) and the root mean square (rms) error of the reference image to the on‐line fluoroscopic images. Results: In order to do efficient gating, the calculation of the correlation of one image to the reference should be 1–10ms and this can be easily achieved in our preliminary study. Also, the correlation can be better calculated by sparsely sampling the calculation pixels around the treatment volume rather than using a local ROI inside the volume. In the former, we found that both the cc and the rms demonstrated good periodicity. As we expected, the external marker locations recorded by the RPM software not always correlate well with the cc and rms. Conclusion: We demonstrated that RGRT by matching the patient's anatomical structures is highly feasible. The reference image can be the one from a gated fluoroscopic image or DRR from a gated CT scan. This technique will allow both gating and tracking and can be significant for high dose high‐precision radiation therapy with reduced margins for moving targets. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1936 / 1936
页数:1
相关论文
共 50 条
  • [1] Automatic Patient Positioning and Gating Window Thresholds for Respiratory-Gated Pancreatic Cancer Stereotactic Body Radiation Therapy Using Fiducial Markers and Orthogonally Acquired Fluoroscopic Images
    Pettersson, N.
    Simpson, D.
    Atwood, T.
    Cervino, L.
    Murphy, J.
    Hattangadi-Gluth, J.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [2] Automatic patient positioning and gating window settings in respiratory-gated stereotactic body radiation therapy for pancreatic cancer using fluoroscopic imaging
    Pettersson, Niclas
    Simpson, Daniel
    Atwood, Todd
    Hattangadi-Gluth, Jona
    Murphy, James
    Cervino, Laura
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02): : 74 - 82
  • [3] Improvement in Accuracy of Respiratory Gated Radiation Therapy Using Respiratory Training System
    Kang, S.
    Kim, T.
    Kim, D.
    Suh, T.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [4] Predictors for Intrafractional Internal-External Relationship Changes in Respiratory-Gated Pancreatic Cancer Stereotactic Body Radiation Therapy
    Pettersson, N.
    Murphy, J.
    Simpson, D.
    Cervino, L.
    MEDICAL PHYSICS, 2018, 45 (06) : E417 - E417
  • [5] Design a Gated and Nongated Respiratory Control Auxiliary System for External Beam Radiation Therapy
    Wu, Jian-Kuen
    Chen, Shih-Han
    Liao, Shu-Hsien
    Wang, Yu-Jen
    MEDICAL PHYSICS, 2019, 46 (06) : E639 - E640
  • [6] Respiratory-Gated Radiation Therapy for the Liver: A 5-Patient Study
    Briere, T. M.
    Krishnan, S.
    Balter, P.
    Nelson, C.
    Starkschall, G.
    Gillin, M. T.
    Beddar, A. S.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [7] Improvement in the accuracy of respiratory-gated radiation therapy using a respiratory guiding system
    Kang, Seong-Hee
    Kim, Dong-Su
    Kim, Tae-Ho
    Suh, Tae-Suk
    Yoon, Jai-Woong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 62 (01) : 159 - 164
  • [8] Improvement in the accuracy of respiratory-gated radiation therapy using a respiratory guiding system
    Seong-Hee Kang
    Dong-Su Kim
    Tae-Ho Kim
    Tae-Suk Suh
    Jai-Woong Yoon
    Journal of the Korean Physical Society, 2013, 62 : 159 - 164
  • [9] Effects of breathing variation on gating window internal target volume in respiratory gated radiation therapy
    Cai, Jing
    McLawhorn, Robert
    Read, Paul W.
    Larner, James M.
    Yin, Fang-fang
    Benedict, Stanley H.
    Sheng, Ke
    MEDICAL PHYSICS, 2010, 37 (08) : 3927 - 3934
  • [10] Intra- and inter-fractional variations of tumors with fiducial markers measured using respiratory-correlated computed tomography images for respiratory gated lung stereotactic body radiation therapy
    Manabe, Yuki
    Shiinoki, Takehiro
    Fujimoto, Koya
    Ueda, Kazushi
    Karita, Masako
    Ono, Taiki
    Kajima, Miki
    Tanaka, Hidekazu
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (06):