Equal modal damping-based optimal design of a grounded tuned mass-damper-inerter for flexible structures

被引:12
|
作者
Chen, Bei [1 ,2 ]
Zhang, Zili [3 ]
Hua, Xugang [1 ]
机构
[1] Hunan Univ, Key Lab Wind & Bridge Engn, Changsha 410082, Peoples R China
[2] Aarhus Univ, Dept Civil & Architectural Engn, Aarhus, Denmark
[3] Tongji Univ, Sch Civil Engn, Shanghai 200092, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
background response; closed-form solution; equal modal damping; flexible structure; pole-placement method; tuned mass-damper-inerter (TMDI); vibration control; VIBRATION ABSORBERS; PERFORMANCE; TMDI;
D O I
10.1002/stc.3106
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
For design of tuned mass-damper-inerter (TMDI) in flexible multi-degrees-of-freedom (MDOF) structures, the classic 2-DOF model is incapable of accounting for the background flexibility that comes from non-resonant modes, leading to an unbalance in the frequency response of the flexible structure-TMDI system. This becomes more critical for the grounded TMDI attached to a lower floor (a practical installation location). This paper proposes a set of closed-form formulas for optimal design of the grounded TMDI based on equal modal damping principle. An analogue 2-DOF model accounting for the background flexibility of the structure is first constructed. The root locus analysis is then performed, and three optimal frequency-tuning formulas are derived by the equal modal damping ratio criterion corresponding to three different damping levels of TMDI. A straightforward approach for determining the optimal TMDI damping ratio is proposed based on the bifurcation point present in the root locus. All the derived optimal design formulas turn out to be dependent on the structural inherent property. The effectiveness of the proposed closed-form formulas are assessed via both frequency-domain and time-history (with earthquake ground motions) analyses of a 10-story building. Results indicate that the proposed design formulas leads to superior performance of the grounded TMDI compared to the conventional formula ignoring background flexibility. When equal modal damping of the system is guaranteed, an excellent level of vibration reduction of structural seismic responses can be achieved.
引用
收藏
页数:27
相关论文
共 50 条
  • [1] Analytical design of non-grounded tuned mass-damper-inerter for base-excited structures
    Li, Zhenchuan
    Xu, Kun
    Wang, Zixiao
    Bi, Kaiming
    Qin, Huailei
    Giaralis, Agathoklis
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2024, 276
  • [2] Tuned mass-damper-inerter control of wind-induced vibration of flexible structures based on inerter location
    Dai, Jun
    Xu, Zhao-Dong
    Gai, Pan-Pan
    ENGINEERING STRUCTURES, 2019, 199
  • [3] Closed-form optimization of tuned mass-damper-inerter (TMDI) in flexible structures
    Zhang, Zili
    Chen, Bei
    Hua, Xugang
    JOURNAL OF BUILDING ENGINEERING, 2023, 72
  • [4] Optimal Design of Tuned Mass-Damper-Inerter for Structure with Uncertain-but-Bounded Parameter
    Zhou, Shaoyi
    Huang, Jungang
    Yuan, Quan
    Ma, Dong
    Peng, Shuangling
    Chesne, Simon
    BUILDINGS, 2022, 12 (06)
  • [5] Optimal tuned mass-damper-inerter (TMDI) design for seismically excited MDOF structures with model uncertainties based on reliability criteria
    Giaralis, A.
    Taflanidis, A. A.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (02):
  • [6] Reliability-based design optimization of tuned mass-damper-inerter for mitigating structural vibration
    Peng, Yongbo
    Sun, Peifang
    JOURNAL OF SOUND AND VIBRATION, 2024, 572
  • [7] Optimal design and performance evaluation of tuned mass damper inerter in building structures
    Caicedo, Daniel
    Lara-Valencia, Luis
    Bland, John
    REVISTA FACULTAD DE INGENIERIA-UNIVERSIDAD DE ANTIOQUIA, 2023, (106): : 66 - 77
  • [8] Dual-Demand-Based Optimal Design of Grounded Tuned Mass Damper Inerter for Seismic Response Mitigation
    Zhang, Ruoyu
    Huang, Jizhong
    Zhang, Yue
    JOURNAL OF VIBRATION ENGINEERING & TECHNOLOGIES, 2024, 12 (02) : 1429 - 1443
  • [9] Dual-Demand-Based Optimal Design of Grounded Tuned Mass Damper Inerter for Seismic Response Mitigation
    Ruoyu Zhang
    Jizhong Huang
    Yue Zhang
    Journal of Vibration Engineering & Technologies, 2024, 12 : 1429 - 1443
  • [10] Feasibility of eddy current damping-based tuned mass damper inerter for a nonlinear hybrid base-isolated building
    Li, Dawei
    Niu, Chuchu
    Xu, Kangqian
    Han, Jianping
    JOURNAL OF BUILDING ENGINEERING, 2025, 104