Polyethylene wear and synovitis in total hip arthroplasty -: A sonographic study of 48 hips

被引:12
|
作者
Kesteris, U [1 ]
Jonsson, K [1 ]
Robertsson, O [1 ]
Önnerfält, R [1 ]
Wingstrand, H [1 ]
机构
[1] Univ Lund Hosp, Dept Orthoped, S-22185 Lund, Sweden
来源
JOURNAL OF ARTHROPLASTY | 1999年 / 14卷 / 02期
关键词
total hip arthroplasty; sonography of the hip; polyethylene wear; synovitis;
D O I
10.1016/S0883-5403(99)90116-X
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Forty-six patients (48 hips), operated on with cemented total hip arthroplasty (THA) because of arthrosis, were examined radiographically and sonographically at 10-year follow-up. Polyethylene wear of acetabular cups was measured on conventional non-weight-bearing pelvic radiographs, and the volume of polyethylene debris was calculated. Radiographic signs of loosening were identified. The capsular distance (ie, thickness of the synovium or synovial contents) was measured sonographically. We found a significant correlation between increased volumetric wear and increased capsular distance. Hips with radiographically loose acetabular components had significantly greater volumetric wear and capsular distance than those without signs of acetabular loosening. This relationship was not observed in hips with radiographically loose femoral components. In cemented THA, the volume of polyethylene wear debris and the thickness of the synovium and the synovial contents are related. In the event of radiographic loosening of the acetabular component, they are both increased.
引用
收藏
页码:138 / 143
页数:6
相关论文
共 50 条
  • [1] Effect of femoral head size on polyethylene wear and synovitis after total hip arthroplasty - A sonographic and radiographic study of 39 patients
    Tarasevicius, Sarunas
    Robertsson, Otto
    Kesteris, Uldis
    Kalesinskas, Romas Jonas
    Wingstrand, Hans
    ACTA ORTHOPAEDICA, 2008, 79 (04) : 489 - 493
  • [2] POLYETHYLENE WEAR IN TOTAL HIP-ARTHROPLASTY
    BANKSTON, AB
    CATES, H
    RITTER, MA
    KEATING, EM
    FARIS, PM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (317) : 7 - 13
  • [3] WEAR OF POLYETHYLENE IN CHARNLEY TOTAL HIP-ARTHROPLASTY
    CLARAC, JP
    PRIES, P
    LAUNAY, L
    MARTIN, P
    FREYCHET, H
    NONET, P
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1986, 72 (02): : 97 - 100
  • [4] Measurement of polyethylene wear in cementless total hip arthroplasty
    Shih, CH
    Lee, PC
    Chen, JH
    Tai, CL
    Chen, LF
    Wu, JSS
    Chang, WH
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (03): : 361 - 365
  • [5] Total Hip Arthroplasty for Fused Hips
    Abdel-Aal, Ahmed
    Bakr, Hatem
    Mahran, Mohamad
    ORTHOPEDICS, 2010, 33 (06) : 400 - 404
  • [6] Sonographic Detection of Acetabular Polyethylene Liner Dissociation in Total Hip Arthroplasty
    Jin, Wook
    Chun, Young Soo
    Park, So Young
    Rhyu, Kee Hyung
    Park, Ji Seon
    Kim, Hyun Cheol
    Yang, Dal Mo
    Ryu, Kyung Nam
    JOURNAL OF ULTRASOUND IN MEDICINE, 2009, 28 (11) : 1597 - 1600
  • [7] In Vivo Measurement of Polyethylene Wear in Cementless Total Hip Arthroplasty
    Roth, A.
    Sander, K.
    Layher, F.
    Babisch, J.
    Venbrocks, R.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2010, 77 (01) : 13 - 17
  • [8] Influence of polyethylene creep behavior on wear in total hip arthroplasty
    Penmetsa, JR
    Laz, PJ
    Petrella, AJ
    Rullkoetter, PJ
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (03) : 422 - 427
  • [9] Wear polyethylene cups in total hip arthroplasty - A study of specimens retrieved post mortem
    Sychterz, CJ
    Moon, KH
    Hashimoto, Y
    Terefenko, KM
    Engh, CA
    Bauer, TW
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (08): : 1193 - 1200
  • [10] Wear of polyethylene cups in total hip arthroplasty: A parametric mathematical model
    Pietrabissa, Riccardo
    Raimondi, Manuela
    Di Martino, Elena
    Medical Engineering and Physics, 1998, 20 (03): : 199 - 210