Optical fiber-based full Mueller polarimeter for endoscopic imaging using a two-wavelength simultaneous measurement method

被引:29
|
作者
Vizet, Jeremy [1 ]
Manhas, Sandeep [1 ,2 ]
Tran, Jacqueline [2 ]
Validire, Pierre [3 ]
Benali, Abdelali [3 ]
Garcia-Caurel, Enric [2 ]
Pierangelo, Angelo [2 ]
De Martino, Antonello [2 ]
Pagnoux, Dominique [1 ]
机构
[1] Univ Limoges, CNRS, Xlim Inst, UMR 7252, 123 Ave A Thomas, F-87000 Limoges, France
[2] Univ Paris Saclay, LPICM, CNRS, Ecole Polytech, F-91128 Palaiseau, France
[3] Inst Mutualiste Montsouris, Dept Anatomopathol, 42 Blvd Jourdan, F-75014 Paris, France
关键词
photonics; polarimetry; endoscopy; optical fibers; Mueller matrix; characterization of biological tissues; POLARIZATION; CALIBRATION; CANCER; DEVICE; STATES;
D O I
10.1117/1.JBO.21.7.071106
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper reports a technique based on spectrally differential measurement for determining the full Mueller matrix of a biological sample through an optical fiber. In this technique, two close wavelengths were used simultaneously, one for characterizing the fiber and the other for characterizing the assembly of fiber and sample. The characteristics of the fiber measured at one wavelength were used to decouple its contribution from the measurement on the assembly of fiber and sample and then to extract sample Mueller matrix at the second wavelength. The proof of concept was experimentally validated by measuring polarimetric parameters of various calibrated optical components through the optical fiber. Then, polarimetric images of histological cuts of human colon tissues were measured, and retardance, diattenuation, and orientation of the main axes of fibrillar regions were displayed. Finally, these images were successfully compared with images obtained by a free space Mueller microscope. As the reported method does not use any moving component, it offers attractive integration possibilities with an endoscopic probe. (C) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Fiber-based two-wavelength heterodyne laser interferometer
    Zhang, Yanqi
    Guzman, Felipe
    OPTICS EXPRESS, 2022, 30 (21): : 37993 - 38008
  • [2] Fiber-based two-wavelength heterodyne displacement interferometer
    Zhang, Yanqi
    Joo, Ki-Nam
    Guzman, Felipe
    PHOTONIC INSTRUMENTATION ENGINEERING IX, 2022, 12008
  • [3] Depolarization Measurement through a Single-Mode Fiber-Based Endoscope for Full Mueller Endoscopic Polarimetric Imaging
    Buckley, Colman
    Fabert, Marc
    Pagnoux, Dominique
    PHOTONICS, 2023, 10 (04)
  • [4] 70 kHz full 4x4 Mueller polarimeter and simultaneous fiber calibration for endoscopic applications
    Rivet, Sylvain
    Bradu, Adrian
    Podoleanu, Adrian
    OPTICS EXPRESS, 2015, 23 (18): : 23768 - 23786
  • [5] A two-wavelength optical method for the high combustion temperature measurement of solid propellant
    Xu, Chao-Qi
    He, Guo-Qiang
    Liu, Pei-Jin
    Li, Peng-Fei
    Guti Huojian Jishu/Journal of Solid Rocket Technology, 2010, 33 (05): : 594 - 598
  • [6] Shape measurement by endoscopic electronic-speckle-pattern interferometry with a two-wavelength method
    Kemper, B
    Kandulla, J
    Knoche, S
    von Bally, G
    SPECKLE METROLOGY 2003, PROCEEDINGS, 2003, 4933 : 129 - 134
  • [7] Study on optical fiber temperature sensor using two-wavelength light sources
    Liu, Ye
    Zhang, Yun
    Wang, Caitang
    Tang, Sheng'an
    Wei, Zhaobi
    Wang, Feng
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2002, 36 (04): : 335 - 338
  • [8] Displacement measurement method based on integrated grating interferometry with two-wavelength lasers
    Chen, Feng
    Ye, Xiong-Ying
    Wu, Kang
    Feng, Jin-Yang
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2012, 20 (11): : 2433 - 2438
  • [9] Two-Wavelength Square-Waveform Generation Based on Fiber Optical Parametric Oscillator
    Yang, Sigang
    Zhang, Chi
    Zhou, Yue
    Wong, Kenneth Kin-Yip
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2010, 58 (11) : 3381 - 3386
  • [10] Two-wavelength method for endoscopic shape measurement by spatial phase-shifting speckle-interferometry
    Kandulla, J
    Kemper, B
    Knoche, S
    von Bally, G
    APPLIED OPTICS, 2004, 43 (29) : 5429 - 5437