Analysis of the voltage distribution in a motor stator winding subjected to steep-fronted surge voltages by means of a multiconductor lossy transmission line model

被引:56
|
作者
Petrarca, C [1 ]
Maffucci, A
Tucci, V
Vitelli, M
机构
[1] Univ Naples Federico II, Dipartimento Ingn Elettr, I-80125 Naples, Italy
[2] Univ Cassino, DAEIMI, I-03043 Cassino, FR, Italy
[3] Univ Salerno, Dip Ing Ing Inform & Ing Elettr, I-84084 Fisciano, SA, Italy
[4] Univ Naples 2, Dip Ing Dell Inform, I-81031 Aversa, CE, Italy
关键词
AC motors; electrical insulation; pulse-width modulation; windings;
D O I
10.1109/TEC.2003.821834
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, the effect of steep-fronted voltage waveshapes infringing on a pulse-width-modulated (PWM) inverter fed induction motor is studied. The system, composed of a feeder cable and a stator winding, is modeled and simulated by using multiconductor transmission line theory in order to predict the voltage distribution among the coils of the stator winding. A recently developed time-domain equivalent circuit is used; it allows one to correctly describe the dielectric losses and the skin-effect in the conductors. The relationship among the voltage distribution inside the electrical insulation and parameters like the rise time of the applied voltage, the cable length, and the distributed losses is deeply discussed. Good agreement has been found among experimental and numerical results.