RETRACTED: Test-Retest Reliability of Dynamic Balance Performance-Based Measures Among Adults With a Unilateral Lower-Limb Amputation (Retracted Article)

被引:9
|
作者
Cardoso, Jefferson R. [1 ,2 ]
Beisheim, Emma H. [1 ,3 ]
Horne, John R. [4 ]
Sions, J. Megan
机构
[1] Univ Delaware, Delaware Limb Loss, Dept Phys Therapy, Newark, DE 19713 USA
[2] Univ Estadual Londrina, Lab Biomech & Clin Epidemiol, PAIFIT Res Grp, Londrina, PR, Brazil
[3] Univ Delaware, Biomech & Movement Sci PhD Program, Newark, DE 19713 USA
[4] Independence Prosthet Orthot Inc, Newark, DE USA
关键词
TO-STAND TEST; FUNCTIONAL REACH; OUTCOME MEASURES; RISK-FACTORS; HOUGHTON SCALE; OLDER-ADULTS; USERS SURVEY; PLUS-M; PEOPLE; VALIDITY;
D O I
10.1016/j.pmrj.2018.07.005
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: There is large variation in administration of performance-based, dynamic balance measures among adults with lower-limb amputation (LLA). Further, there has been limited exploration of test-retest reliability of these measures in adults with lower-limb loss, including whether there is a difference in reliability if one records "best" vs "average" performance across trials. Objective: To determine test-retest reliability of several balance tests for both "best" and "average" score performance in community-dwelling adults with a unilateral LLA, including quantification of the precision of individual scores (SE of the measurement, SEM) and estimates of minimal detectable change (MDC90). Design: Cross-sectional study. Setting: Mobile research laboratory. Participants: 27 participants (55.5% female) with an average age of 51 (SD = 12.2) years, who were predominantly communityambulators (92.5%), after a unilateral transtibial (n = 20), transfemoral (n = 5), or other major lower-extremity (n = 2) amputation, were included. Median time since amputation was 6.3 (2.3, 19 [25th, 75th interquartile range]) years. Methods: Reliability was evaluated using intraclass correlation coefficient (ICC) models (3,1 or 3, k) . SEMs and MDC90 values with 95% confidence intervals (Cis) were calculated. Main Outcome Measures: 360 degrees Turn Test, 5 Times Sit-To-Stand, Functional Reach Test, Figure-of-8 Walk Test, and Four Square Step Test (FSST). Results: The ICCs (3,1 or 3,k) for all tests (for both "best" and "average" performance) were considered good-to-excellent and Cls varied from 0.69 (95% CI = 0.40-0.85) to 0.97 (95% CI = 0.95-0.99). For most tests, "best" and "average" performance demonstrated similar ICC values. MDC90 values did not surpass 10% of test means for any of the measures. Conclusions: The dynamic balance measures evaluated for use among community-dwelling adults with a unilateral LLA demonstrated excellent reliability, along with high precision of scores and MDC values that did not exceed 10% of testing means. Either best or average scoring may be used when administering the majority of these tests, as long as the assessment method is appropriately documented and replicated at follow-up to allow direct comparisons. With the FSST, clinicians should consider taking the average of two FSST trials.
引用
收藏
页码:243 / 251
页数:9
相关论文
共 9 条
  • [1] RETRACTION: Test-retest reliability of dynamic balance performance-based measures among adults with a unilateral lower-limb amputation (Retraction of Vol 11, Pg 243, 2019)
    Cardoso, J. R.
    Beisheim, E. H.
    Horne, J. R.
    Sions, J. M.
    PM&R, 2019, 11 (09) : 1036 - 1036
  • [2] Test-retest reliability for performance-based outcome measures among individuals with arthrogryposis multiplex congenita
    Sions, Jaclyn Megan
    Donohoe, Maureen
    Beisheim-Ryan, Emma Haldane
    Pohlig, Ryan Todd
    Shank, Tracy Michele
    Nichols, Louise Reid
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [3] Gait asymmetry is associated with performance-based physical function among adults with lower-limb amputation
    Seth, Mayank
    Coyle, Peter C.
    Pohlig, Ryan T.
    Beisheim, Emma H.
    Horne, John R.
    Hicks, Gregory E.
    Sions, Jaclyn Megan
    PHYSIOTHERAPY THEORY AND PRACTICE, 2022, 38 (13) : 3108 - 3118
  • [4] Interrater and Test-Retest Reliability of Performance-Based Clinical Tests Administered to Established Users of Lower Limb Prostheses
    Sawers, Andrew
    Kim, Janis
    Balkman, Geoff
    Hafner, Brian J.
    PHYSICAL THERAPY, 2020, 100 (07): : 1206 - 1216
  • [5] TEST-RETEST RELIABILITY OF POSTURAL SWAY MEASURES DURING STATIC STANDING BALANCE PERFORMANCE IN HEALTHY ELDERLY ADULTS
    Kwon, Yu-Ri
    Eom, Gwang-Moon
    Kim, Ji-Won
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2022, 22 (08)
  • [6] Test–retest reliability for performance-based outcome measures among individuals with arthrogryposis multiplex congenita
    Jaclyn Megan Sions
    Maureen Donohoe
    Emma Haldane Beisheim-Ryan
    Ryan Todd Pohlig
    Tracy Michele Shank
    Louise Reid Nichols
    BMC Musculoskeletal Disorders, 23
  • [7] Test-retest reliability of the special interest group on amputation medicine/Dutch working group on amputations and prosthetics mobility scale, in persons wearing a prosthesis after a lower-limb amputation
    de Laat, Fred A.
    Roorda, Leo D.
    Geertzen, Jan H.
    Rommers, Clemens
    DISABILITY AND REHABILITATION, 2020, 42 (12) : 1762 - 1766
  • [8] Associations of lower-limb muscle strength performance with static and dynamic balance control among older adults in Taiwan
    Yeh, Ping-Chun
    Syu, De-Kai
    Ho, Chien-Chang
    Lee, Tian-Shyug
    FRONTIERS IN PUBLIC HEALTH, 2024, 12
  • [9] Clinician-administered performance-based tests via telehealth in people with chronic lower limb musculoskeletal disorders: Test-retest reliability and agreement with in-person assessment
    Lawford, Belinda J.
    Dobson, Fiona
    Bennell, Kim L.
    Merolli, Mark
    Graham, Bridget
    Haber, Travis
    Teo, Pek Ling
    Mackenzie, Dave
    McManus, Fiona
    Lamb, Karen E.
    Hinman, Rana S.
    JOURNAL OF TELEMEDICINE AND TELECARE, 2024, 30 (08) : 1300 - 1319