Performance of the Thin Superconducting Solenoid of the CMD-3 Detector

被引:6
|
作者
Bragin, Alexey V. [1 ]
Barkov, Lev M. [1 ]
Bashtovoj, Nikolay S. [1 ]
Grebenuk, Andrej A. [1 ]
Karpov, Sergey V. [1 ]
Okhapkin, Victor S. [1 ]
Pivovarov, Sergey G. [1 ]
Popov, Yuri S. [1 ]
Ruban, Alexander A. [1 ]
Khazin, Boris I. [1 ]
机构
[1] Budker Inst Nucl Phys, Novosibirsk 630090, Russia
关键词
Detector magnet; subdivision protection; thin superconducting solenoid; MAGNETS;
D O I
10.1109/TASC.2010.2061843
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A thin superconducting solenoid is designed to provide a magnetic field of 1.5 T in the CMD-3 detector. The solenoid and an LXe calorimeter are placed in the common vacuum vessel of the detector. The solenoid is passively protected by subdivision and inductive coupling methods. The radiation thickness of the coil is 0.085X(0), and the achieved E/M ratio is 6.9 kJ/kg. In 2007, the solenoid was tested in a prototype iron yoke, where the operational parameters were achieved. This paper reports the performance of the solenoid in the CMD-3 detector. The solenoid has been operated safely at a 1.35-T magnetic field. There were 19 quenches caused by various factors at magnetic fields in the range of 0.6-1.38 T. After a quench, the solenoid absorbed about 40% of the stored energy and warmed up to 42-55 K. A significant influence of quench-induced eddy currents on the detector design elements was observed. Liquid helium consumption at steady operation was about 3.5 L/h. Possible application of the achieved results to designing thinner solenoids is discussed.
引用
收藏
页码:2336 / 2340
页数:5
相关论文
共 50 条
  • [1] Test results of the thin superconducting solenoid for the CMD-3 detector
    Bragin, Alexey V.
    Barkov, Lev M.
    Karpov, Sergey V.
    Okhapkin, Victor S.
    Popov, Yuri S.
    Ruban, Alexander A.
    Smakhtin, Vladimir P.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2008, 18 (02) : 399 - 402
  • [2] Superconducting power supply for thin superconducting solenoid of the CMD-3 detector
    Karpov, Sergey V.
    Bragin, Alexey V.
    Ruban, Alexander A.
    Popov, Yuri S.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2006, 16 (02) : 1642 - 1645
  • [3] Indirectly Cooled Superconducting Power Supply for the CMD-3 Thin Solenoid
    Karpov, Sergey V.
    Bragin, Alexey V.
    Ruban, Alexander A.
    Okhapkin, Victor S.
    Popov, Yuri S.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2018, 28 (03)
  • [4] Calorimetry of the CMD-3 detector
    Shebalin, V. E.
    Akhmetshin, R. R.
    Anisenkov, A. V.
    Aulchenko, V. M.
    Bashtovoy, N. S.
    Epifanov, D. A.
    Epshteyn, L. B.
    Erofeev, A. L.
    Grebenuk, A. A.
    Grigoriev, D. N.
    Ignatov, F. V.
    Kazanin, V. F.
    Kovalenko, O. A.
    Kozyrev, A. N.
    Kuzmenko, A. E.
    Kuzmin, A. S.
    Logashenko, I. B.
    Mikhailov, K. Yu.
    Okhapkin, V. S.
    Razuvaev, G. P.
    Ruban, A. A.
    Shwartz, B. A.
    Titov, V. M.
    Talyshev, A. A.
    Yudin, Yu. V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 824 : 710 - 712
  • [5] Calorimetry of the CMD-3 detector
    Akhmetshin, R. R.
    Anisenkov, A. V.
    Aulchenko, V. M.
    Bashtovoy, N. S.
    Epifanov, D. A.
    Epshteyn, L. B.
    Erofeev, A. L.
    Grebenuk, A. A.
    Grigoriev, D. N.
    Kazanin, V. F.
    Kovalenko, O. A.
    Kozyrev, A. N.
    Kuzmenko, A. E.
    Kuzmin, A. S.
    Logashenko, I. B.
    Mikhailov, K. Yu
    Okhapkin, V. S.
    Razuvaev, G. P.
    Ruban, A. A.
    Shebalin, V. E.
    Shwartz, B. A.
    Titov, V. M.
    Talyshev, A. A.
    Yudin, Yu V.
    17TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN PARTICLE PHYSICS (CALOR2016), 2017, 928
  • [6] Performance of the BGO endcap calorimeter of the CMD-3 detector
    Akhmetshin, R. R.
    Grigoriev, D. N.
    Kazanin, V. F.
    Kuzmenko, A. E.
    Yudin, Yu. V.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [7] Drift chamber for the CMD-3 detector
    Grancagnolo, F.
    Fiore, G.
    Ignatov, F. V.
    Karavdina, A. V.
    Khazin, B. I.
    Miccoli, A.
    Okhapkin, V. S.
    Pivovarov, S. G.
    Popov, A. S.
    Ruban, A. A.
    Sibidanov, A. L.
    Snopkov, I. G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (01): : 114 - 116
  • [8] Drift chamber for the CMD-3 detector
    Grancagnolo, F.
    Fiore, G.
    Ignatov, F. V.
    Karavdina, A. V.
    Khazin, B. I.
    Miccoli, A.
    Pivovarov, S. G.
    Popov, A. S.
    Ruban, A. A.
    Sibidanov, A. L.
    Snopkov, I. G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (01): : 105 - 106
  • [9] Barrel calorimeter of the CMD-3 detector
    V. E. Shebalin
    A. V. Anisenkov
    V. M. Aulchenko
    N. S. Bashtovoy
    D. A. Epifanov
    L. B. Epshteyn
    A. A. Grebenuk
    F. V. Ignatov
    A. L. Erofeev
    O. A. Kovalenko
    A. N. Kozyrev
    A. S. Kuzmin
    I. B. Logashenko
    K. Yu. Mikhailov
    G. P. Razuvaev
    A. A. Ruban
    B. A. Shwartz
    A. A. Talyshev
    V. M. Titov
    Yu. V. Yudin
    Physics of Atomic Nuclei, 2015, 78 : 1544 - 1551
  • [10] Barrel Calorimeter of the CMD-3 Detector
    Shebalin, V. E.
    Anisenkov, A. V.
    Aulchenko, V. M.
    Bashtovoy, N. S.
    Epifanov, D. A.
    Epshteyn, L. B.
    Erofeev, A. L.
    Grebenuk, A. A.
    Ignatov, F. V.
    Kovalenko, O. A.
    Kozyrev, A. N.
    Kuzmin, A. S.
    Logashenko, I. B.
    Mikhailov, K. Yu.
    Razuvaev, G. P.
    Ruban, A. A.
    Shwartz, B. A.
    Talyshev, A. A.
    Titov, V. M.
    Yudin, Yu. V.
    PHYSICS OF ATOMIC NUCLEI, 2015, 78 (13) : 1544 - 1551