Measurement of Directed Blood Flow by Laser Speckle

被引:0
|
作者
Hirst, Evan R. [1 ]
Thompson, Oliver B. [1 ]
Andrews, Michael K. [1 ]
机构
[1] Ind Res Ltd, Lower Hutt 5040, New Zealand
关键词
Laser Speckle; Retina; Blood Flow; VISUALIZATION; VELOCITY;
D O I
10.1117/12.873664
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Recent success in reconciling laser Doppler and speckle measurements of dermal perfusion by the use of multi-exposure speckle has prompted an investigation of speckle effects arising from directed blood flow which might be expected in the small blood vessels of the eye. Unlike dermal scatter, the blood in retinal vessels is surrounded by few small and stationary scatterers able to assist the return of light energy by large-angle scatter. Returning light is expected to come from multiple small angle scatter from the large red blood cells which dominate the fluid. This work compares speckle measurements on highly scattering skin, with measurements on flow in a retinal phantom consisting of a glass capillary which is itself immersed in an index matching fluid to provide a flat air-phantom interface. Brownian motion dominated measurements when small easily levitated scatters were used, and flow was undetectable. With whole-blood, Brownian motion was small and directed flows in the expected region of tens of mm/s were detectable. The nominal flow speed relates to the known pump rate; within the capillary the flow will have a profile reducing toward the walls. The pulsatile effects on laser speckle contrast in the retina are discussed with preliminary multi-exposure measurements on retinal vessels using a fundus camera. Differences between the multiple exposure curves and power spectra of perfused tissue and ordered flow are discussed.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Choroid blood flow measurement with laser speckle flowgraphy in macular disease
    Kim, Seong-Woo
    Oh, Jaeryung
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (08) : 1083 - 1084
  • [2] Self-mixing laser speckle velocimeter for blood flow measurement
    Özdemir, SK
    Takamiya, S
    Ito, S
    Shinohara, S
    Yoshida, H
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2000, 49 (05) : 1029 - 1035
  • [3] Non-invasive capillary blood flow measurement: Laser speckle and laser doppler
    Jayanthy, A.K.
    Sujatha, N.
    Reddy, M. Ramasubba
    World Academy of Science, Engineering and Technology, 2011, 77 : 1007 - 1012
  • [4] VISUALIZATION AND MEASUREMENT OF RETINAL BLOOD-FLOW BY MEANS OF LASER SPECKLE PHOTOGRAPHY
    FERCHER, AF
    PEUKERT, M
    ROTH, E
    OPTICAL ENGINEERING, 1986, 25 (06) : 731 - 735
  • [5] Development of the portable blood flow measurement system using laser speckle flowgraphy
    Shibata, Takumi
    Lee, Min-Chul
    Konishi, Naoki
    2013 INTERNATIONAL CONFERENCE ON ICT CONVERGENCE (ICTC 2013): FUTURE CREATIVE CONVERGENCE TECHNOLOGIES FOR NEW ICT ECOSYSTEMS, 2013, : 955 - 958
  • [6] Development of a handheld blood flow measurement system using laser speckle flowgraphy
    Lee, Min-Chul
    Konishi, Naoki
    Fujii, Hitoshi
    OPTICAL REVIEW, 2015, 22 (02) : 308 - 314
  • [7] Development of a handheld blood flow measurement system using laser speckle flowgraphy
    Min-Chul Lee
    Naoki Konishi
    Hitoshi Fujii
    Optical Review, 2015, 22 : 308 - 314
  • [8] Laser Speckle Flow Imaging of Cerebral Blood Flow
    Nakaji, Peter
    WORLD NEUROSURGERY, 2014, 82 (06) : E697 - E698
  • [9] Laser speckle imaging of blood flow in microcirculation
    Cheng, HY
    Luo, QM
    Liu, Q
    Lu, QA
    Gong, H
    Zeng, SQ
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (07): : 1347 - 1357
  • [10] Laser speckle microscopy measurement of arteriolar blood flow in many individual nephrons simultaneously
    Holstein-Rathlou, Niels-Henrik
    Sosnovtseva, Olga
    Laugesen, Jakob
    Cupples, William
    Marsh, Donald J.
    FASEB JOURNAL, 2010, 24