Reference measurements of mercury species in seafood using isotope dilution inductively coupled plasma mass spectrometry

被引:6
|
作者
Krata, Agnieszka Anna [1 ,2 ]
Wojciechowski, Marcin [1 ]
Vassileva, Emilia [2 ]
Bulska, Ewa [1 ]
机构
[1] Univ Warsaw, Biol & Chem Res Ctr, Fac Chem, Zwirki & Wigury 101, PL-02089 Warsaw, Poland
[2] IAEA, Marine Environm Studies Lab, 4 Quai Antoine 1er, MC-98000 Monaco, Monaco
关键词
Food composition; Food analysis; Seafood; Clam; Oyster; Fish homogenate; Mercury species; HPLC ID ICP-MS; Method validation; Quality control; METHYL MERCURY; SPECIATION ANALYSIS; GAS-CHROMATOGRAPHY; ICP-MS; FISH; SAMPLES; HPLC; METHYLMERCURY; PERFORMANCE; FRACTIONS;
D O I
10.1016/j.jfca.2019.103381
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Species-specific isotope dilution inductively coupled plasma mass spectrometry (SS ID ICP-MS) and high-performance liquid chromatography (HPLC) were used to obtain accurate and SI traceable results for methyl mercury in seafood samples such as clam, oyster and fish homogenate. The mass fractions of (62.3 +/- 2.3) mu g kg(-1), (5.44 +/- 0.36) mu g kg(-1) and (531 19) mu g kg(-1) were obtained for MeHg (as Hg) in IAEA-461, IAEA-470 and IAEA-476, respectively. Direct isotope dilution mass spectrometry was performed for total mercury content then the content of inorganic mercury in selected samples was obtained by calculation. It was found that the content of inorganic Hg in IAEA-461, IAEA-470, and IAEA-476 was as: 328 mu g kg(-1), 16 mu g kg(-1), and 62 mu g kg(-1), respectively. Mathematical modelling of analytical procedure and evaluation of all parameters influencing final results were adequate for validation of measurement procedure, establishing traceability and estimating expanded uncertainty. Developed procedures were successfully applied in the characterization process of fish homogenate candidate reference material and in the calculation of assigned values in the frame of IAEA-476 inter-laboratory comparison study. Compatibility between obtained results and those derived from the certification campaign, organized by International Atomic Energy Agency on the same sample matrix (< 2.6 % difference) further validated performed ID ICP-MS protocols.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Reference measurements for total mercury and methyl mercury content in marine biota samples using direct or species-specific isotope dilution inductively coupled plasma mass spectrometry
    Krata, Agnieszka
    Vassileva, Emilia
    Bulska, Ewa
    TALANTA, 2016, 160 : 562 - 569
  • [2] Reference Measurements for Priority and Essential Trace Elements and Methyl Mercury with Isotope Dilution Inductively Coupled Plasma-Mass Spectrometry for Seafood Safety Assessment and CRM Production
    Garcia, Miriam
    Vassileva, Emilia
    Azemard, Sabine
    Canals, Antonio
    FOOD ANALYTICAL METHODS, 2020, 13 (02) : 390 - 402
  • [3] Reference Measurements for Priority and Essential Trace Elements and Methyl Mercury with Isotope Dilution Inductively Coupled Plasma-Mass Spectrometry for Seafood Safety Assessment and CRM Production
    Miriam García
    Emilia Vassileva
    Sabine Azemard
    Antonio Canals
    Food Analytical Methods, 2020, 13 : 390 - 402
  • [4] Reference measurements for cadmium, copper, mercury, lead, zinc and methyl mercury mass fractions in scallop sample by isotope dilution inductively coupled plasma mass spectrometry
    Vassileva, Emilia
    Wysocka, Irena
    Betti, Maria
    MICROCHEMICAL JOURNAL, 2014, 116 : 197 - 205
  • [5] Determination of mercury in fish by isotope dilution inductively coupled plasma-mass spectrometry
    Wang Meng
    Zhang Yu
    Feng Wei-Yue
    Guan Ming
    Wang Bing
    Shi Jun-Wen
    Zhu Mo-Tao
    Li Bai
    Zhao Yu-Liang
    Chai Zhi-Fang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (07) : 945 - 948
  • [6] Speciation of Mercury in Microalgae by Isotope Dilution-inductively Coupled Plasma Mass Spectrometry
    Song, Beibei
    He, Huijun
    Chen, Lufeng
    Yang, Shifeng
    Yin Yongguang
    Li, Yanbin
    ANALYTICAL LETTERS, 2017, 50 (13) : 2161 - 2176
  • [7] Isotope ratio and isotope dilution measurements using axial inductively coupled plasma time of flight mass spectrometry
    Emteborg, H
    Tian, XD
    Ostermann, M
    Berglund, M
    Adams, FC
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (03) : 239 - 246
  • [8] Isotope ratio and isotope dilution measurements using axial inductively coupled plasma time of flight mass spectrometry
    Emteborg, Hakan, 1600, Royal Soc of Chemistry, Cambridge, United Kingdom (15):
  • [9] Determination of mercury in urine by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry
    Lee, KH
    Jiang, SJ
    Liu, HW
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (11) : 1227 - 1231
  • [10] Determination of Chromium and Mercury in Sediments by Isotope Dilution-Inductively Coupled Plasma Mass Spectrometry
    Wu J.
    Chao J.-B.
    Peng Y.
    Wang J.
    Yang X.-J.
    Journal of Chinese Mass Spectrometry Society, 2017, 38 (06) : 647 - 654