An amperometric glucose biosensor based on a screen-printed electrode and Os-complex mediator for flow injection analysis

被引:27
|
作者
Liu, Jian [1 ]
Sun, Shanhui [2 ]
Liu, Changchun [1 ]
Wei, Shoushui [1 ]
机构
[1] Shandong Univ, Sch Control Sci & Engn, Jinan 250061, Peoples R China
[2] Shandong Univ, Jinan Cent Hosp, Jinan 250013, Peoples R China
基金
中国博士后科学基金;
关键词
Biosensor; Screen-printed; Os-complex mediated; FIA; Amperometric; CARBON; OXIDASE; FIA; IMMOBILIZATION; STABILITY; CELL;
D O I
10.1016/j.measurement.2011.09.001
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
An amperometric Os-complex mediated glucose biosensor based on a three electrodes planar configuration was constructed using screen printing technique for flow injection analysis. The electrochemical characteristic of the amperometric biosensor was evaluated by the cyclic voltammetry in the absence and presence of Os-complex mediator. The Os-complex mediated biosensor was found to have a C-V curve close to an ideal. The applied potential of the biosensor had been explored and -0.1 V vs. Ag vertical bar AgCl reference electrode was selected for avoiding excessive interference from other electroactive species. The biosensor also indicated good stability of more than 90% of its original activity for about 14 months stored at 4 degrees C. The biosensor on the detection of glucose showed a linear response range of 0.5-30 mM and the correlation coefficient up to 0.99 together with a FIA system. The coefficient of variation was 3.3% for injections with a single biosensor (n = 12). The results show that the biosensor has fast response, good sensitivity and reproducibility for flow injection analysis. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1878 / 1883
页数:6
相关论文
共 50 条
  • [1] Flow injection analytical system for glucose with screen-printed enzyme biosensor incorporating Os-complex mediator
    Zhang, CX
    Gao, Q
    Aizawa, M
    ANALYTICA CHIMICA ACTA, 2001, 426 (01) : 33 - 41
  • [2] A sensitive biosensor based on Os-complex mediator and glucose oxidase for low concentration glucose determination
    Jiang, Liying
    Liu, Hongmin
    Liu, Jian
    Yang, Qingde
    Cai, Xinxia
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2008, 619 : 11 - 16
  • [3] A mediator-free screen-printed amperometric biosensor for screening of organophosphorus pesticides with flow-injection analysis (FIA) system
    Shi, MH
    Xu, JJ
    Zhang, S
    Liu, BH
    Kong, JL
    TALANTA, 2006, 68 (04) : 1089 - 1095
  • [4] A disposable glucose biosensor based on diffusional mediator dispersed in nanoparticulate membrane on screen-printed carbon electrode
    Gao, ZQ
    Xie, F
    Shariff, M
    Arshad, M
    Ying, JY
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 111 : 339 - 346
  • [5] A disposable glucose biosensor based on diffusional mediator dispersed in nanoparticulate membrane on screen-printed carbon electrode
    Gao, Z
    Xie, F
    Arshad, MSM
    Ying, JY
    NSTI NANOTECH 2004, VOL 1, TECHNICAL PROCEEDINGS, 2004, : 209 - 212
  • [6] Amperometric screen-printed algal biosensor with flow injection analysis system for detection of environmental toxic compounds
    Shitanda, Isao
    Takamatsu, Satoshi
    Watanabe, Kunihiro
    Itagaki, Masayuki
    ELECTROCHIMICA ACTA, 2009, 54 (21) : 4933 - 4936
  • [7] A highly sensitive flow injection amperometric glucose biosensor using a gold nanoparticles/polytyramine/Prussian blue modified screen-printed carbon electrode
    Khumngern, Suntisak
    Jirakunakorn, Ratchaneekorn
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Numnuam, Apon
    Bioelectrochemistry, 2021, 138
  • [8] A highly sensitive flow injection amperometric glucose biosensor using a gold nanoparticles/polytyramine/Prussian blue modified screen-printed carbon electrode
    Khumngern, Suntisak
    Jirakunakorn, Ratchaneekorn
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Numnuam, Apon
    BIOELECTROCHEMISTRY, 2021, 138
  • [9] Flow Injection Tyrosinase Amperometric Biosensor with A Single-Layer Graphene Modified Screen-Printed Electrode for Determination of Acetaminophen
    Frangu, Arber
    Sys, Milan
    Arbneshi, Tahir
    Vytras, Karel
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE MODERN ELECTROCHEMICAL METHODS XXXVIII, 2018, : 50 - 53
  • [10] Physical characterizations of a screen-printed electrode for use in an amperometric biosensor system
    Grennan, K
    Killard, AJ
    Smyth, MR
    ELECTROANALYSIS, 2001, 13 (8-9) : 745 - 750