Is flow-mediated dilatation associated with near-infrared spectroscopy-derived magnitude of muscle O2 desaturation in healthy young and individuals at risk for cardiovascular disease?

被引:12
|
作者
de Oliveira, Gustavo Vieira [1 ,2 ]
Volino-Souza, Monica [1 ,3 ]
Leitao, Renata [1 ]
Pinheiro, Vivian [1 ]
Alvares, Thiago Silveira [1 ,2 ,3 ]
机构
[1] Univ Fed Rio de Janeiro, Nutr & Exercise Metab Res Grp, Macae Campus, Rio De Janeiro, Brazil
[2] Univ Fed Rio de Janeiro, Postgrad Program Bioact Prod & Biosci, Macae, RJ, Brazil
[3] Univ Fed Rio de Janeiro, Chem Inst, Postgrad Program Food Sci, Rio De Janeiro, RJ, Brazil
关键词
Endothelial dysfunction; Microvascular responsiveness; Muscular dysfunction; NIRS; Ischemic stimulus; ENDOTHELIAL DYSFUNCTION; BRACHIAL-ARTERY;
D O I
10.1016/j.mvr.2019.103967
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Vascular occlusion test (VOT)-induced reactive hyperemia in brachial artery is crucial to flow-mediated dilation (FMD). Emerging studies have suggested that reactive hyperemia depends on the magnitude of the O-2 desaturation (ischemia) in downstream microvessels. Although near-infrared spectroscopy-derived tissue O-2 saturation index (TSI) has been used to assess the magnitude of ischemia, the association between FMD and the magnitude of O-2 desaturation has not been addressed. Therefore, the aim of the present study was to evaluate whether FMD correlates with the magnitude of muscle O-2 desaturation in healthy young individuals and older adults at risk for cardiovascular disease (CVD). Twenty healthy young individuals and 20 others at risk for CVD participated in the study. The magnitude of ischemic stimulus was determined by calculating the area under curve of TSI signal over 5 min of cuff occlusion period. Oxygen resaturation rate was calculated as the upslope of the TSI signal over 10 s following cuff deflation. There was no significant correlation between FMD and the magnitude of ischemic stimulus in both groups assessed (young: R = 0.327; P = 0.159 and older: R = - 0.184; P = 0.436). However, a significant correlation between the magnitude of O-2 desaturation and O-2 resaturation rate in young (R = 0.555; P = 0.011) and older individuals at risk for CVD (R = 0.539; P = 0.014). In conclusion, FMD response did not correlate with the magnitude of muscle O-2 desaturation, although it seems to be partially associated with O-2 resaturation rate.
引用
收藏
页数:6
相关论文
共 10 条
  • [1] The association between near-infrared spectroscopy-derived and flow-mediated dilation assessment of vascular responsiveness in the arm
    Soares, Rogerio N.
    Somani, Yasina B.
    Proctor, David N.
    Murias, Juan M.
    MICROVASCULAR RESEARCH, 2019, 122 : 41 - 44
  • [2] The association between near-infrared spectroscopy assessment of microvascular reactivity and flow-mediated dilation is disrupted in individuals at high risk for cardiovascular disease
    de Oliveira, Gustavo Vieira
    Soares, Rogerio Nogueira
    Volino-Souza, Monica
    Murias, Juan Manuel
    Alvares, Thiago Silveira
    MICROCIRCULATION, 2019, 26 (07)
  • [3] Near-infrared spectroscopy-derived muscle oxygen saturation during exercise recovery and flow-mediated dilation are impaired in HIV-infected patients
    Volino-Souza, Monica
    de Oliveira, Gustavo Vieira
    Barros-Santos, Elisa
    Pinheiro, Vivian
    Machado-Santos, Ana Paula
    Conte-Junior, Carlos A.
    Alvares, Thiago Silveira
    MICROVASCULAR RESEARCH, 2020, 130
  • [4] The influence of cardiovascular risk factors on near-infrared spectroscopy-derived muscle oxygen saturation during exercise recovery in older adults
    de Oliveira, Gustavo Vieira
    Volino-Souza, Monica
    Barros-Santos, Elisa
    Conte-Junior, Carlos Adam
    Alvares, Thiago Silveira
    SPORT SCIENCES FOR HEALTH, 2022, 18 (04) : 1221 - 1228
  • [5] The influence of cardiovascular risk factors on near-infrared spectroscopy-derived muscle oxygen saturation during exercise recovery in older adults
    Gustavo Vieira de Oliveira
    Mônica Volino-Souza
    Elisa Barros-Santos
    Carlos Adam Conte-Junior
    Thiago Silveira Alvares
    Sport Sciences for Health, 2022, 18 : 1221 - 1228
  • [6] Near-infrared spectroscopy-derived muscle V?O2${\dot{V}_{{{\rm{O}}_{\rm{2}}}}}$ kinetics after moderate running exercise in healthy males: reliability and associations with parameters of aerobic fitness
    de Aguiar, Rafael A.
    Turnes, Tiago
    Borszcz, Fernando K.
    Raimundo, Joao A. G.
    Caputo, Fabrizio
    EXPERIMENTAL PHYSIOLOGY, 2022, 107 (05) : 476 - 488
  • [7] Performance of near-infrared spectroscopy in measuring local O2 consumption and blood flow in skeletal muscle
    van Beekvelt, MCP
    Colier, WNJM
    Wevers, RA
    van Engelen, BGM
    JOURNAL OF APPLIED PHYSIOLOGY, 2001, 90 (02) : 511 - 519
  • [8] Muscle capillary blood flow kinetics estimated from pulmonary O2 uptake and near-infrared spectroscopy
    Ferreira, LF
    Townsend, DK
    Lutjemeier, BJ
    Barstow, TJ
    JOURNAL OF APPLIED PHYSIOLOGY, 2005, 98 (05) : 1820 - 1828
  • [9] Measurement of muscle blood flow and O2 uptake via near-infrared spectroscopy using a novel occlusion protocol
    Dennis, Joshua J.
    Wiggins, Chad C.
    Smith, Joshua R.
    Isautier, Jennifer M. J.
    Johnson, Bruce D.
    Joyner, Michael J.
    Cross, Troy J.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [10] Measurement of muscle blood flow and O2 uptake via near-infrared spectroscopy using a novel occlusion protocol
    Joshua J. Dennis
    Chad C. Wiggins
    Joshua R. Smith
    Jennifer M. J. Isautier
    Bruce D. Johnson
    Michael J. Joyner
    Troy J. Cross
    Scientific Reports, 11