共 1 条
Image registration of the human accommodating eye demonstrates equivalent increases in lens equatorial radius and central thickness
被引:1
|作者:
Grzybowski, Andrzej
[1
,2
]
Schachar, Ronald A.
[3
]
Gaca-Wysocka, Magdalena
[2
]
Schachar, Ira H.
[4
]
Pierscionek, Barbara K.
[5
]
机构:
[1] Inst Res Ophthalmol, PL-60554 Poznan, Poland
[2] Univ Warmia & Maztuy, Dept Ophthalmol, PL-10082 Olsztyn, Poland
[3] Univ Texas Arlington, Dept Phys, POB 19059, Arlington, TX 76019 USA
[4] Stanford Univ, Sch Med, Byers Eye Inst, Dept Ophthalmol,Horngren Family Vitreoretinal Ctr, Palo Alto, CA 94304 USA
[5] Nottingham Trent Univ, Sch Sci & Technol, Nottingham NG1 4FQ, England
关键词:
image registration;
accommodation;
equatorial lens radius;
central lens thickness;
CRYSTALLINE LENS;
ABERRATION;
MECHANISM;
GRADIENT;
GRAVITY;
SURFACE;
D O I:
10.18240/ijo.2019.11.14
中图分类号:
R77 [眼科学];
学科分类号:
100212 ;
摘要:
AIM: To compare the results of in vivo human high resolution image registration studies of the eye during accommodation to the predictions of mathematical and finite element models of accommodation. METHODS: Data from published high quality image registration studies of pilocarpine induced accommodative changes of equatorial lens radius (ELR) and central lens thickness (CLT) were statistically analyzed. RESULTS: The mean changes in ELR and CLT were 6.76 mu m/diopter and 6.51 mu m/diopter, respectively. The linear regressions, reflecting the association between ELR and accommodative amplitude (AA(ELR)) was: slope=6.58 mu m/diopter, r(2)=0.98, P<0.0001 and between CLT and AACLT was: slope=6.75 mu m/diopter, r(2) =0.83, P<0.001. On the basis of these relationships, the CLT slope and the AA(ELR) were used to predict the measured change in ELR (ELRpredicted) There was no statistical difference between ELRpredicted and the measured ELR as demonstrated by a Student's paired t-test: P=0.96 and linear regression analysis: slope=0.97, r(2) =0.98, P<0.00001. CONCLUSION: Image registration with invariant positional references demonstrates that ELR and CLT equivalently minimally increase similar to 7.0 mu m/diopter during accommodation. The small equivalent increases in ELR and CLT are associated with a large accommodative amplitude. These findings are consistent with the predictions of mathematical and finite element models that specified the stiffness of the lens nucleus is the same or greater than the lens cortex and that accommodation involves a small force (<5 g).
引用
收藏
页码:1751 / 1757
页数:7
相关论文