Automated sample preparation and GC-API-MS/MS as a powerful tool for analysis of legacy POPs in human serum and plasma

被引:4
|
作者
Huber, Sandra [1 ]
Averina, Maria [1 ,2 ]
Brox, Jan [1 ,3 ]
机构
[1] Univ Hosp North Norway, Dept Lab Med, Div Diagnost Serv, Hansine Hansens Veg 67, NO-9038 Tromso, Norway
[2] UiT Arctic Univ Norway, Dept Community Med, Fac Hlth Sci, Hansine Hansens Veg 18, NO-9038 Tromso, Norway
[3] UiT Arctic Univ Norway, Dept Med Biol, Fac Hlth Sci, Hansine Hansens Veg 18, NO-9038 Tromso, Norway
关键词
PERSISTENT ORGANIC POLLUTANTS; POLYBROMINATED DIPHENYL ETHERS; SOLID-PHASE EXTRACTION; POLYCHLORINATED-BIPHENYLS; ORGANOCHLORINE PESTICIDES; GAS-CHROMATOGRAPHY; DISK EXTRACTION; WOMEN; MICROEXTRACTION; SPECTROMETRY;
D O I
10.1039/c9ay02400j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated high-throughput solid phase extraction method for selected persistent organic pollutants (POPs) comprising 17 organochlorine pesticides, 22 polychlorinated biphenyls (PCBs), 9 polybrominated diphenylethers (PBDEs) and octachlorostyrene (OCS) in human serum and plasma was developed. Importance was attached to application of small volumes of reagents and solvents in addition to low sample volumes (150 mu L) in order to save the highly valuable sample material for follow-up and other studies. Instrumental analysis was performed by gas chromatography with atmospheric pressure ionisation coupled to tandem mass spectrometry (GC-API-MS/MS). The recoveries of the selected analytes were satisfactory and between 70% and 120% for most of the compounds at three investigated spike concentrations (75 pg mL(-1), 450 pg mL(-1) and 1250 pg mL(-1)). Inter-day recoveries were within 80-120% for pesticides and within 86-130% for PCBs and PBDEs with RSDs ranging from 2% to 35%. The accuracy of the method was evaluated with standard reference materials and samples from the ringtest of the Arctic Monitoring and Assessment Programme and was slightly better with lower RSDs for most of the compounds compared to that of previously published methods. Method detection limits (MDLs) ranged from 0.009 pg mL(-1) to 34.6 pg mL(-1) for pesticides, from 0.435 pg mL(-1) to 57.8 pg mL(-1) for PCBs and from 0.855 pg mL(-1) to 34.6 pg mL(-1) for PBDEs when blank contamination was taken into account. Low MDLs together with high accuracy, repeatability and robustness were demonstrated for an appropriate concentration range. The applicability for real samples was satisfactorily demonstrated by analysis of 40 serum samples from the general population of Tromso, Norway, where in total 33 analytes were measured above the MDLs. The most important marker compounds are detected in this low exposure population which shows the suitability of the presented method for retrospective as well as prospective studies with high number of samples.
引用
收藏
页码:912 / 929
页数:18
相关论文
共 50 条
  • [1] Temperature as a sample preparation tool in the analysis of materials by GC-MS
    Wampler, TP
    LC GC NORTH AMERICA, 1999, 17 (09) : S14 - +
  • [2] AUTOMATED SAMPLE PREPARATION AND GC-MS ANALYSIS OF CHLORINATED COMPOUNDS IN WATER
    TAMILARASAN, R
    MORABITO, PL
    BUTT, A
    HAZELWOOD, PD
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1994, 12 (10): : 774 - &
  • [3] Automated sample preparation of GC-MS analysis exemplified by the analysis of petroleum hydrocarbons in water
    Lerch, O
    Zinn, P
    AMERICAN LABORATORY, 2000, 32 (25) : 14 - 15
  • [4] Quantification of 4-Beta-Hydroxycholesterol in Human Plasma Using Automated Sample Preparation and LC-ESI-MS/MS Analysis
    Goodenough, Angela K.
    Onorato, Joelle M.
    Ouyang, Zheng
    Chang, Shu
    Rodrigues, A. David
    Kasichayanula, Sreeneeranj
    Huang, Shu-Pang
    Turley, Wesley
    Burrell, Richard
    Bifano, Marc
    Jemal, Mohammed
    LaCreta, Frank
    Tymiak, Adrienne
    Wang-Iverson, David
    CHEMICAL RESEARCH IN TOXICOLOGY, 2011, 24 (09) : 1575 - 1585
  • [5] GC-APLI-MS as a powerful tool for the analysis of BaP-tetraol in human urine
    Richter-Brockmann, Sigrid
    Dettbarn, Gerhard
    Jessel, Soenke
    John, Andrea
    Seidel, Albrecht
    Achten, Christine
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1100 : 1 - 5
  • [6] Automated processing of sample preparation for homocysteine analysis using LC-MS/MS
    Jun, S.
    Lee, K.
    Song, J.
    CLINICA CHIMICA ACTA, 2022, 530 : S288 - S288
  • [7] Novel Sample Preparation and GC-MS/MS Analysis of Triclosan and Methyl Triclosan in Biosolids
    Bozlee, M.
    LC GC NORTH AMERICA, 2018, 36 (02) : 28 - 33
  • [8] A fully automated plasma protein precipitation sample preparation method for LC-MS/MS bioanalysis
    Ma, Ji
    Shi, Jianxia
    Le, Hoa
    Cho, Robert
    Huang, Judy Chi-jou
    Miao, Shichang
    Wong, Bradley K.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 219 - 226
  • [9] Investigation of Metoprolol Concentrations in Plasma Using Automated Sample Preparation and LC-MS/MS Detection
    Cioroiu, Ionel-Bogdan
    Dobrin, Mona-Elisabeta
    Niculaua, Marius
    Nechita, Constantin-Bogdan
    Cotea, Valeriu V.
    SEPARATIONS, 2024, 11 (11)
  • [10] Improved sample preparation and GC–MS analysis of priority organic pollutants
    Olga V. Polyakova
    Dmitry M. Mazur
    Albert T. Lebedev
    Environmental Chemistry Letters, 2014, 12 : 419 - 427