Analysis of Inter-turn Fault Symptoms for the Converter-Fed Induction Motor Based on the Phase-Shift Calculation

被引:3
|
作者
Kowalski, Czeslaw T. [1 ]
Orlowska-Kowalska, Teresa [1 ]
Wierzbicki, Robert [1 ]
Wolkiewicz, Marcin [1 ]
机构
[1] Wroclaw Univ Technol, Inst Elect Machines Drives & Measurements, PL-50370 Wroclaw, Poland
来源
IECON 2010: 36TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY | 2010年
关键词
DIAGNOSIS;
D O I
10.1109/IECON.2010.5675029
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper a stator fault detection method based on monitoring of the phase shift between the line currents and phase voltages of the converter-fed induction motor is presented. The phase shift analysis is used as an indicator of the stator-fault-progression level. The mathematical model of induction motor, which includes the stator-winding fault is presented. The fault level is modeled by change of a number of shorted stator-winding turns. Next the new fault indicator is introduced. Comparison of simulation and experimental results of the converter-fed induction motor for different number of shorted turns and different load torque conditions is shown. Proper fault severity is obtained with the proposed fault indicator.