A visualization tool for improved assessment and follow-up with ultrasound

被引:0
|
作者
Kiss, Gabriel [1 ,2 ]
Iversen, Daniel Hoyer [1 ,2 ,3 ]
Standal, Oyvind Krovel-Velle [1 ,2 ]
Rau, Jochen Matthias [1 ,2 ]
Torp, Hans [1 ,2 ]
Lovstakken, Lasse [1 ,2 ]
Masoy, Svein-Erik [1 ,2 ]
机构
[1] Norwegian Univ Sci & Technol, MI Lab, N-7034 Trondheim, Norway
[2] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, N-7034 Trondheim, Norway
[3] SINTEF Med Technol, Trondheim, Norway
关键词
POWER DOPPLER ULTRASOUND; RHEUMATOID-ARTHRITIS;
D O I
10.1109/ULTSYM.2014.0587
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound has been shown to be a powerful imaging tool for the evaluation of musculoskeletal disease (e.g. rheumatoid arthritis or carpal tunnel syndrome). Power Doppler imaging in particular plays an important role in treatment monitoring. However it is also known that ultrasound is operator dependent and has low intra-and inter-observer repeatability. The aim of this work was to reduce the uncertainty of the follow-up process of a typical musculoskeletal exam by ensuring that the same anatomy is visualized at baseline and follow-up. A visualization tool, which receives a continuous stream of ultrasound data, has been implemented in Qt. The streamed images are compared on the fly against a pre-loaded baseline image. To compensate for in plane translation and rotation differences, 2D rigid registration is performed. Normalized mutual information was used as a similarity metric and is color coded from red (0%) to green (100%) to show the amount of similarity among the current images. Several display alternatives (e.g. semi-transparent overlay, color coded overlay) have been implemented and tested. Optional anisotropic filtering can be applied to both images before registration to reduce the impact of the speckle noise on the final result. Two healthy volunteers and a phantom have been used for validation purposes. Both the reference and follow-up ultrasound data have been acquired with a Vivid E9 scanner, with an ML6-15 probe (GE Vingmed Ultrasound). At the same time the position of the probe with regards to a reference frame was tracked with an accurate optical position sensor (Polaris, NDI). It was shown that the highest similarity scores corresponded to the lowest translation offsets and angle differences. The average offset and angle errors for the patient data were: [0.68 +/- 0.97, 0.47 +/- 0.79, -2.28 +/- 1.38] mm, [2.92 +/- 2.35, -0.17 +/- 1.2, 1.24 +/- 2.38]degrees. A novel method for real-time fusion of ultrasound images aimed at musculoskeletal disease monitoring has been presented. Being provided with instant feedback, the user is more confident during the acquisition process.
引用
收藏
页码:2355 / 2358
页数:4
相关论文
共 50 条
  • [1] Ultrasound for Assessment and Follow-up of Airway Stenosis
    Fiorelli, Alfonso
    Messina, Gaetana
    Bove, Mary
    Natale, Giovanni
    Noro, Antonio
    Cascone, Roberto
    Opromolla, Giorgia
    Testa, Domenico
    Motta, Gaetano
    Santini, Mario
    ANNALS OF THORACIC SURGERY, 2022, 113 (05): : 1624 - 1633
  • [2] Kidney ultrasound is useful tool in posttransplant follow-up
    Chiang, Y. -J.
    Chu, S. -H.
    Liu, K-L.
    Lai, W. -J.
    Wang, H. -H.
    Chen, H. -W.
    Wang, T. -M.
    Huang, J. -Y.
    Lai, P. -C.
    Tian, Y. -C.
    TRANSPLANTATION PROCEEDINGS, 2006, 38 (07) : 2018 - 2019
  • [3] An AI-Based Tool for Improved Follow-up Assessment of Brain Metastases after Radiotherapy
    Kumar, Y.
    Fiveash, J. B.
    Chang, H. H. R.
    Katherine, H. A.
    Popple, R. A.
    Cardenas, C. E.
    MEDICAL PHYSICS, 2024, 51 (10) : 7650 - 7650
  • [4] Use of high-frequency ultrasound for follow-up and visualization of intracanalicular plugs
    Kuestner, M.
    Tost, F.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2006, 16 (02) : 354 - 355
  • [5] Nerve ultrasound as follow-up tool in treated multifocal motor neuropathy
    Rattay, T. W.
    Winter, N.
    Decard, B. F.
    Dammeier, N. M.
    Haertig, F.
    Ceanga, M.
    Axer, H.
    Grimm, A.
    EUROPEAN JOURNAL OF NEUROLOGY, 2017, 24 (09) : 1125 - 1134
  • [6] ULTRASOUND IN THE POSTOPERATIVE FOLLOW-UP
    DESLEGTE, R
    NEUROPEDIATRICS, 1984, 15 (04) : 230 - 230
  • [7] USING A NEEDS ASSESSMENT TOOL IN BREAST CANCER FOLLOW-UP
    Cruickshank, Susanne
    Barber, D. M.
    Kennedy, C.
    Rowat, A.
    Small, R.
    EJC SUPPLEMENTS, 2010, 8 (06): : 36 - 36
  • [8] Improved follow-up procedure
    Ohm, OJ
    Danilovic, D
    Faerestrand, S
    CARDIAC ARRHYTHMIAS, PACING & ELECTROPHYSIOLOGY: THE EXPERT VIEW, 1998, 201 : 411 - 419
  • [9] Ultrasound as a screening tool in the follow-up of asymptomatic congenital cystic adenomatoid malformation
    Adin, Mehmet Emin
    ULTRASOUND, 2016, 24 (03) : 175 - 179
  • [10] ULTRASOUND IN GOUT: A USEFUL TOOL FOR FOLLOW-UP WITH URATE-LOWERING THERAPY
    Ottaviani, S.
    Gill, G.
    Aubrun, A.
    Palazzo, E.
    Meyer, O.
    Dieude, P.
    ANNALS OF THE RHEUMATIC DISEASES, 2014, 73 : 62 - 63