Development of a coupled-column liquid chromatographic tandem mass spectrometric method for the direct determination of betamethasone in urine

被引:40
|
作者
Polettini, A [1 ]
Bouland, GM [1 ]
Montagna, M [1 ]
机构
[1] Univ Pavia, Dept Legal Med & Publ Hlth, I-27100 Pavia, Italy
来源
JOURNAL OF CHROMATOGRAPHY B | 1998年 / 713卷 / 02期
关键词
mass spectrometry; betamethasone;
D O I
10.1016/S0378-4347(98)00177-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Different hyphenated liquid chromatographic (LC) and mass spectrometric (MS) techniques were investigated in,order to set-up a method for the fast, direct analysis of betamethasone in hydrolysed and non-hydrolysed urine using large-volume sample injection. After the optimisation of the LC parameters using a traditional UV detector and of the thermospray and mass spectrometric parameters by flow injection, urine samples (0.5 mi) were submitted to analysis by either LC combined with tandem mass spectrometry (MS-MS), coupled-column LC (LC-LC) combined with single quadrupole MS, and LC-LC-MS-MS. Both the three-step configurations (LC-MS-MS and LC-LC-MS) did not provide satisfactory results: loss of sensitivity was noted in the case of LC-MS-MS (likely due to reduced efficiency in the ionisation of betamethasone in the thermospray owing to the presence of large amounts of matrix interference), while in the case of LC-LC-MS a high chemical noise resulting in insufficient selectivity of detection was observed. On the contrary, LC-LC-MS-MS analysis proved to meet the demand of high speed of analysis (sample throughput, 4.5 h(-1)), selectivity, and sensitivity (LOQ, 1 ng/ml; LOD, 0.2 ng/ml). Notwithstanding the complex analytical system adopted, the developed procedure was manageable and very robust, provided that at the beginning of each analytical session the performance of the system was controlled by checking the retention time of the analytes on the first analytical column with UV detection and by optimising vaporiser temperature of the thermospray by flow injection. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:339 / 352
页数:14
相关论文
共 50 条
  • [1] Development and validation of a liquid chromatographic-tandem mass spectrometric method for the determination of pibutidine in human urine
    Kato, K
    Jingu, S
    Ogawa, N
    Higuchi, S
    JOURNAL OF CHROMATOGRAPHY B, 2000, 740 (02): : 187 - 193
  • [2] Coupled-column liquid chromatographic analysis of catecholamines, serotonin, and metabolites in human urine
    Panholzer, TJ
    Beyer, J
    Lichtwald, K
    CLINICAL CHEMISTRY, 1999, 45 (02) : 262 - 268
  • [3] Development and validation of a liquid chromatographic/tandem mass spectrometric method for the determination of sertraline in human plasma
    Chen, Xiaoyan
    Duan, Xiaotao
    Dai, Xiaojian
    Zhong, Dafang
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (16) : 2483 - 2489
  • [4] Automated liquid chromatographic/tandem mass spectrometric method for screening β-blocking drugs in urine
    Gergov, M
    Robson, JN
    Duchoslav, E
    Ojanperä, I
    JOURNAL OF MASS SPECTROMETRY, 2000, 35 (07): : 912 - 918
  • [5] Direct Determination of 1-Naphthol in Human Urine by Coupled-Column Liquid Chromatography with Fluorescence Detection
    J.V. Sancho
    R.A. Cabanes
    F.J. López
    F. Hernández
    Chromatographia, 2003, 58 : 565 - 569
  • [6] Development and validation of a liquid chromatographic-tandem mass spectrometric method for the determination of caffeic acid phenethyl ester in rat plasma and urine
    Celli, N
    Mariani, B
    Dragani, LK
    Murzilli, S
    Rossi, C
    Rotilio, D
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 810 (01): : 129 - 136
  • [7] Direct determination of 1-naphthol in human urine by coupled-column liquid chromatography with fluorescence detection
    Sancho, JV
    Cabanes, RA
    López, FJ
    Hernández, F
    CHROMATOGRAPHIA, 2003, 58 (9-10) : 565 - 569
  • [8] Development and validation of a liquid chromatographic-tandem mass spectrometric method for determination of eleven coccidiostats in milk
    Nasz, Szilard
    Debreczeni, Lajos
    Rikker, Tamas
    Eke, Zsuzsanna
    FOOD CHEMISTRY, 2012, 133 (02) : 536 - 543
  • [9] Improved coupled-column liquid chromatographic method for the determination of glyphosate and aminomethylphosphonic acid residues in environmental waters
    Hidalgo, C
    Rios, C
    Hidalgo, M
    Salvadó, V
    Sancho, JV
    Hernández, F
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1035 (01) : 153 - 157
  • [10] Sensitive liquid chromatographic/tandem mass spectrometric method for the determination of beclomethasone dipropionate and its metabolites in equine plasma and urine
    Guan, FY
    Uboh, C
    Soma, L
    Hess, A
    Luo, Y
    Tsang, DS
    JOURNAL OF MASS SPECTROMETRY, 2003, 38 (08): : 823 - 838