Enzyme-assisted extraction and liquid chromatography-inductively coupled plasma mass spectrometry for the determination of arsenic species in fish

被引:22
|
作者
Zhao, Fa [1 ]
Liu, Yanming [1 ]
Zhang, Xiqi [1 ]
Dong, Rui [1 ]
Yu, Wenjiang [1 ]
Liu, Yanfang [2 ]
Guo, Zhimou [2 ]
Liang, Xinmiao [2 ]
Zhu, Jianhua [1 ]
机构
[1] Shandong Inst Food & Drug Control, Jinan 250100, Shandong, Peoples R China
[2] Chinese Acad Sci, Dalian Inst Chem Phys, Dalian, Peoples R China
关键词
Fish; Arsenic species; Protease; Ammonium carbonate; Kinetic energy discrimination; HPLC-ICP-MS; ATOMIC-ABSORPTION-SPECTROMETRY; SOLID-PHASE EXTRACTION; HPLC-ICP-MS; MULTIELEMENTAL SPECIATION ANALYSIS; WATER SAMPLES; FLUORESCENCE SPECTROMETRY; DRINKING-WATER; SEPARATION; SEAFOOD; SELENIUM;
D O I
10.1016/j.chroma.2018.08.068
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive, simple and rapid method for the simultaneous determination of eleven arsenic species has been developed. A high performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS) technique was used for the analysis of eleven arsenic species in less than 17 min. Different extraction solutions were explored and the recovery results using water and aqueous acidic solvents, aqueous organic solvents and enzymes showed that 40 mg protease with 0.75 mL 0.5% hydrochloric acid (v/v) as the extraction agent gave the best experimental results. Species separation with ammonium carbonate solution as the mobile phase was conducted on an anion-exchange chromatographic column using gradient elution. The column temperature was 20 degrees C and kinetic energy discrimination (KED) was employed to eliminate spectral interference. The use of KED mode effectively removed interference from (ArCl)-Ar-75. The detection limit (L-D) of the method was in the range of 0.11-0.59 mu g kg(-1). Repeatability values obtained for spiked real fish samples were in the range of 1.1%-7.6%. Accuracy was calculated based on the analysis of spiked real fish samples at five concentration levels. Obtained recoveries were 91%-106%. The validated method was used in a pilot study to analyze real samples of fish, the organic arsenic especially AsB was the major arsenic specie present in the analyzed samples, only trace amount of inorganic arsenic were detected. The analytical method should improve the assessment of human exposure associated with arsenic intake from fish. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:48 / 58
页数:11
相关论文
共 50 条
  • [1] Determination of five arsenic species in rice by liquid chromatography-inductively coupled plasma-mass spectrometry
    Gong Jiadi
    Cao Xiaolin
    Cao Zhaoyun
    Bian Yingfang
    Yu Shasha
    Chen Mingxue
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2014, 32 (07) : 717 - 722
  • [2] Enzyme-assisted extraction and liquid chromatography mass spectrometry for the determination of arsenic species in chicken meat
    Liu, Qingqing
    Peng, Hanyong
    Lu, Xiufen
    Le, X. Chris
    ANALYTICA CHIMICA ACTA, 2015, 888 : 1 - 9
  • [3] DETERMINATION OF ARSENIC SPECIES IN FISH BY DIRECTLY COUPLED HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY
    BRANCH, S
    EBDON, L
    ONEILL, P
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (01) : 33 - 37
  • [4] Simultaneous determination of arsenic and selenium species in fish tissues using microwave-assisted enzymatic extraction and ion chromatography-inductively coupled plasma mass spectrometry
    Reyes, Laura Hinojosa
    Mar, Jorge L. Guzman
    Rahman, G. M. Mizanur
    Seybert, Bryan
    Fahrenholz, Timothy
    Kingston, H. M. Skip
    TALANTA, 2009, 78 (03) : 983 - 990
  • [5] Liquid chromatography-inductively coupled plasma mass spectrometry
    Sutton, KL
    Caruso, JA
    JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) : 243 - 258
  • [6] Liquid chromatography-inductively coupled plasma mass spectrometry
    Montes-Bayón, M
    DeNicola, K
    Caruso, JA
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) : 457 - 476
  • [7] Measurement of arsenic species in marine macroalgae by microwave-assisted extraction and high performance liquid chromatography-inductively coupled plasma mass spectrometry
    Tukai, R
    Maher, WA
    McNaught, IJ
    Ellwood, MJ
    ANALYTICA CHIMICA ACTA, 2002, 457 (02) : 173 - 185
  • [8] Determination of Arsenic and Its Species in Dry Seafood by High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry
    Gao Yang
    Cao Xuan
    Yu Jing-Jing
    Lee, Fran Sen-Chun
    Wang Xiao-Ru
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (12) : 1738 - 1742
  • [9] Speciation of Arsenic in Fish by High-Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometry
    Ozcan, Sefika
    Bakirdere, Sezgin
    Ataman, Osman Yavuz
    ANALYTICAL LETTERS, 2016, 49 (15) : 2501 - 2512
  • [10] Determination of Arsenic Species in Urine Samples of Subjects Not Exposed to Dietary Arsenic by High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry
    Moreda-Pineiro, Jorge
    Cantarero-Roldan, Alicia
    Hermelo-Herbello, Paloma
    Moreda-Pineiro, Antonio
    Bermejo-Barrera, Pilar
    ATOMIC SPECTROSCOPY, 2015, 36 (06) : 237 - 246