Optimal Electrode Configurations for Impedance Pneumography during Sports Activities

被引:0
|
作者
Lahtinen, O. [1 ]
Seppa, V. -P. [1 ]
Vaisanen, J. [1 ]
Hyttinen, J. [1 ]
机构
[1] Tampere Univ Technol, Dept Biomed Engn, FIN-33101 Tampere, Finland
关键词
Bioimpedance; impedance pneumography; motion artifacts; wireless;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, we examined the effect of electrode locations to the motion artifacts during sports activities for impedance-based respiration measurement. The tests were performed with a previously developed wireless bioimpedance device. The aim was to discover which configurations would yield the maximum signal-to-artifact ratio (SAR). We had eight different electrode locations and 11 different configurations were compared. The test contained two parts, at first the measurements were performed by sitting in place on a chair and thereafter by running on a treadmill. The measurements show that the electrode locations which improve SAR can be determined but they slightly vary between the individuals.
引用
收藏
页码:1750 / 1753
页数:4
相关论文
共 50 条
  • [2] IMPEDANCE PNEUMOGRAPHY IN MICE - ELECTRODE DESIGN AND EFFECT OF ELECTRODE LOCATION
    PODER, TC
    EWING, KL
    OHIO JOURNAL OF SCIENCE, 1978, 78 (02) : 82 - 85
  • [3] Novel electrode configuration for highly linear impedance pneumography
    Seppa, Ville-Pekka
    Hyttinen, Jan I.
    Uitto, Marko
    Chrapek, Wojciech
    Viik, Jan I.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58 (01): : 35 - 38
  • [4] ELECTRODE MOTION ARTIFACTS IN ELECTRICAL-IMPEDANCE PNEUMOGRAPHY
    SAHAKIAN, AV
    TOMPKINS, WJ
    WEBSTER, JG
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (06) : 448 - 451
  • [5] Optimal Short Distance Electrode Locations for Impedance Pneumography Measurement from the Frontal Thoracic Area
    Jeyhani, V.
    Vuorinen, T.
    Noponen, K.
    Mantysalo, M.
    Vehkaoja, A.
    XIV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING 2016, 2016, 57 : 1138 - 1143
  • [6] Can we optimize electrode placement for impedance pneumography?
    Khambete, N
    Metherall, P
    Brown, B
    Smallwood, R
    Hose, R
    ELECTRICAL BIOIMPEDANCE METHODS: APPLICATIONS TO MEDICINE AND BIOTECHNOLOGY, 1999, 873 : 534 - 542
  • [7] REDUCING ELECTRODE MOTION ARTIFACTS IN ELECTRICAL-IMPEDANCE PNEUMOGRAPHY
    SAHAKIAN, AV
    TOMPKINS, WJ
    WEBSTER, JG
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (08) : 570 - 570
  • [8] A LONG-TERM ELECTRODE SYSTEM FOR ELECTROCARDIOGRAPHY AND IMPEDANCE PNEUMOGRAPHY
    DAY, JL
    LIPPITT, MW
    PSYCHOPHYSIOLOGY, 1964, 1 (02) : 174 - 182
  • [9] Electrode Comparison for Textile-Integrated Electrocardiogram and Impedance Pneumography Measurement
    Tuohimaki, K.
    Mahdiani, S.
    Jeyhani, V.
    Vehkaoja, A.
    Iso-Ketola, P.
    Vanhala, J.
    Viik, J.
    Mantysalo, M.
    EMBEC & NBC 2017, 2018, 65 : 302 - 305
  • [10] ELECTRODE CONFIGURATIONS AND IMPEDANCE SPECTRA OF CEMENT PASTES
    FORD, SJ
    MASON, TO
    CHRISTENSEN, BJ
    COVERDALE, RT
    JENNINGS, HM
    GARBOCZI, EJ
    JOURNAL OF MATERIALS SCIENCE, 1995, 30 (05) : 1217 - 1224