Effect of different retraction and impression techniques on the marginal fit of crowns

被引:29
|
作者
Woestmann, Bernd [1 ]
Rehmann, Peter [1 ]
Trost, Dieter
Balkenhol, Markus [1 ]
机构
[1] Univ Giessen, Dept Prosthodont, D-35392 Giessen, Germany
关键词
finish line; gingival retraction; marginal discrepancy; marginal fit; impression taking; in vitro study;
D O I
10.1016/j.jdent.2008.03.013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Periodontal conditions in restored teeth are strongly influenced by the marginal fit of the restoration which is closely related to the quality of the impression. However, the influence of the retraction and impression technique on the outcome of the impression has only sparsely been investigated. Thus, it was the objective of this study to compare the marginal fit in fixed restorations using two modes of gingival retraction and two different impression techniques in an animal model. Methods: To simulate clinical conditions, 6 teeth in each of 10 lower jaws of freshly slaughtered cows were prepared with subgingival finish lines. Two different retraction techniques were used to expose the finish line: retraction cords containing epinephrine (Surgident) and electro-surgery were applied contra-laterally at 3 teeth per quadrant. Two impressions per jaw were taken in a two-step putty-wash technique (TPW) and a one-step putty-wash technique (OPW), respectively. On the casts, measurement copings were fabricated and seated on the extracted original tooth. In each coping the marginal discrepancy was assessed at 8 reference marks. Since the data was normally distributed, results were subjected to parametric statistics (T-test; p = 0.05). Results: Overall marginal discrepancies ranged between 0 and 200 mu m. There was a small but not significant difference between electro-surgery and the retraction cords whereas TPW produced significantly better results than OPW (p < 0.05). Conclusions: Within the limits of the study it can be concluded that the use of gingival retraction cords as well as electro-surgery lead to acceptable results. The difference between TPW and OPW concerning the marginal discrepancies can be regarded as clinically insignificant. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:508 / 512
页数:5
相关论文
共 50 条
  • [1] Effect of Various Putty-Wash Impression Techniques on Marginal Fit of Cast Crowns
    Nissan, Joseph
    Rosner, Ofir
    Bukhari, Mohammed Amin
    Ghelfan, Oded
    Pilo, Raphael
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2013, 33 (01) : E37 - E42
  • [2] Effect of Different Wax Pattern Manufacturing Techniques on the Marginal Fit of Lithium Disilicate Crowns
    Alshehri, Huda Ahmed
    Altaweel, Sara Mohammed
    Alshaibani, Raghdah
    Alahmari, Esraa Ahmed
    Alotaibi, Hanan Nejer
    Alfouzan, Afnan Fouzan
    Labban, Nawaf
    MATERIALS, 2022, 15 (14)
  • [3] EFFECT OF IMPRESSION MATERIALS AND TECHNIQUES ON THE MARGINAL FIT OF METAL CASTINGS
    GELBARD, S
    AOSKAR, Y
    ZALKIND, M
    STERN, N
    JOURNAL OF PROSTHETIC DENTISTRY, 1994, 71 (01): : 1 - 6
  • [4] Evaluation of Internal Fit and Marginal Adaptation of Provisional Crowns Fabricated with Three Different Techniques
    Wu, Jie
    Xie, Hongjun
    Sadr, Alireza
    Chung, Kwok-Hung
    SENSORS, 2021, 21 (03) : 1 - 15
  • [5] THE MARGINAL FIT OF CROWNS AND BRIDGES
    SPIEKERMANN, H
    DEUTSCHE ZAHNARZTLICHE ZEITSCHRIFT, 1986, 41 (10): : 1015 - 1017
  • [6] Effect of different resin luting cements on the marginal fit of lithium disilicate pressed crowns
    Mounajjed, Radek
    Salinas, Thomas J.
    Ingr, Tomas
    Azar, Basel
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (06): : 975 - 980
  • [7] Marginal fit of titanium crowns produced with two different systems
    Reich, S
    Kretschmar, W
    Brauner, H
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 267 - 267
  • [8] Effect of Additive and Subtractive Coping Production Techniques on Retention and Marginal Fit of Implant Supported Crowns
    Cesmeci, Hayriye Senturk
    Gumus, Hasan Onder
    Ozcan, Mutlu
    JOURNAL OF ORAL IMPLANTOLOGY, 2023, 49 (02) : 157 - 167
  • [9] THE EFFECT OF FIRING SHRINKAGE ON THE MARGINAL FIT OF PORCELAIN JACKET CROWNS
    LUI, JL
    BRITISH DENTAL JOURNAL, 1980, 149 (02) : 43 - 45
  • [10] Clinical marginal fit of zirconia crowns and patients' preferences for impression techniques using intraoral digital scanner versus polyvinyl siloxane material
    Sakornwimon, Nawapat
    Leevailoj, Chalermpol
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (03): : 386 - 391