摘要
This paper aims to determine cost optimality between heating, ventilation and air conditioning (HVAC) systems operating with air to water heat pumps (AWHP) and water to water heat pumps (WWHP). The analysis is performed for a certain number of heat pump units with fixed and variable capacity made by four manufacturers available on European market. Simulations are performed in Trnsys software. The results show that heat pump partial load efficiency should not be neglected in analysis of application while the difference in energy consumption and costs can be up to 17%. The requirement for performing analysis on a wider range of units is indicated, especially when heat pump systems with different sources are considered. HVAC system with AWHP units with capacity control is a cost optimal solution for case study nursery building operating on the Croatian coast. The application of the photovoltaic (PV) array sized to cover nonrenewable part of electricity consumed in HVAC system has a return period of 12 years. It is determined that seasonal efficiency indicators from relevant European database do not support unit operation.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Application of mine water for water-source heat pump system
    Du, Hongpu
    Dou, Yuanming
    Qi, Chengying
    ADVANCES IN ENERGY SCIENCE AND TECHNOLOGY, PTS 1-4, 2013, 291-294 : 1701 - +
  • [2] Cost optimal sizing of photovoltaic-battery system and air-water heat pump in the Mediterranean area
    Nicoletti, Francesco
    Cucumo, Mario Antonio
    Arcuri, Natale
    ENERGY CONVERSION AND MANAGEMENT, 2022, 270
  • [3] MODIFIED WATER LOOP HEAT PUMP SYSTEM FOR A HOSPITAL WITH COMPLEX HVAC SYSTEMS
    Pavkovic, Branimir
    Delac, Boris
    Mrakovcic, Tomislav
    TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2012, 19 (03): : 621 - 631
  • [4] Modified water loop heat pump system for a hospital with complex HVAC systems
    Pavković, Branimir
    Delač, Boris
    Mrakovčić, Tomislav
    Tehnicki Vjesnik, 2012, 19 (03): : 621 - 631
  • [5] Comparison study of the renewable water source heat pump system with the conventional system
    Jung, Hyunjun
    Shin, Jaewoo
    Yun, Rin
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2024, 38 (03) : 1557 - 1568
  • [6] Comparison study of the renewable water source heat pump system with the conventional system
    Hyunjun Jung
    Jaewoo Shin
    Rin Yun
    Journal of Mechanical Science and Technology, 2024, 38 : 1557 - 1568
  • [7] Flooded Mine Water-to-Air Heat Pump System
    Kelso, Richard M.
    Johnson, W. Stanley
    ASHRAE JOURNAL, 2015, 57 (08) : 34 - +
  • [8] AIR-TO-WATER HEAT-PUMP CHILLER SYSTEM - AN ANALYSIS OF VARIANCE IN ANNUAL ELECTRICITY CONSUMPTION
    AGAWA, M
    KOMATSU, M
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1983, 25 (12): : 70 - 70
  • [9] THE APPLICATION OF WATER SOURCE HEAT PUMP WITH LAKE AND RIVER WATER
    Chan, S. H.
    Chung, L. K.
    Ba, F.
    2ND INTERNATIONAL CONFERENCE ON WASTE ENGINEERING MANAGEMENT, ICWEM 2010, 2010, 73 : 420 - 427
  • [10] MODELING OF A WATER WATER HEAT-PUMP, ANALYSIS OF OPTIMAL LOAD
    HABERSCHILL, P
    LALLEMAND, A
    REVUE GENERALE DE THERMIQUE, 1986, 25 (290): : 69 - 80