Electrospray ionization mass spectrometry of soybean lipoxygenases: N-terminal acetylation, chemical modification, and solution conformation

被引:4
|
作者
Peariso, Amber M. [1 ]
Nicholson, Kellie M. [1 ]
Jones, R. Benjamin [2 ]
Green-Church, Kari B. [2 ]
Funk, Max., Jr. [1 ]
机构
[1] Univ Toledo, Dept Chem, Toledo, OH 43606 USA
[2] Ohio State Univ, Campus Chem Instrument Ctr, Mass Spectrometry & Proteom Facil, Columbus, OH 43210 USA
关键词
lipoxygenase; mass; electrospray; acetylation; conformation; N-terminal; post-translational; modification; unfolding;
D O I
10.1002/prot.21543
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Electrospray ionization mass spectrometry was used to examine both the covalent structure and solution conformation of the soybean lipoxygenases. The post-translational modifications of two lipoxgyenases were identified as N-terminal acetylations by tandem mass spectrometry of peptides generated by trypsin digestion. The N-terminal sequence suggests that the proteins were substrates for the plant homolog of the N-terminal acetyltransferase complex C in yeast. Analysis of samples of native lipoxygenase-3 produced ions corresponding within experimental error to the mass of the N-acetylated polypeptide and one iron atom. The precision of the measurements was within roughly 100 ppm for the 96,856 Da protein. This made it possible to detect the addition of a single oxygen atom to the enzyme in a chemical modification reaction with cumene hydroperoxide. The acid-induced denaturation of lipoxygenase-3, which was accompanied by nearly complete loss of catalytic activity, was observed below pH 3.5 with the appearance of ions in the mass spectrum derived from the apoprotein. There was no evidence for the loss of iron in the absence of unfolding. Solutions of lipoxygenase-3 incubated in 0.1M acetic acid produced ions with a novel charge state distribution suggesting a unique conformation. Circular dichroism measurements showed that the secondary structure features of the native protein were retained in the new conformation. Dynamic light scattering revealed that the new conformation was not a consequence of protein aggregation as the hydrodynamic radius of lipoxygenase-3 was significantly smaller in acetic acid solution than at pH 7.0. Remarkably, the enzyme incubated in acetic acid retained full catalytic activity.
引用
收藏
页码:650 / 658
页数:9
相关论文
共 50 条
  • [1] Peptide sequencing through N-terminal phosphonylation and electrospray ionization mass spectrometry
    Bao, JY
    Ai, HW
    Fu, H
    Jiang, YY
    Zhao, YF
    Huang, C
    JOURNAL OF MASS SPECTROMETRY, 2005, 40 (06): : 772 - 776
  • [2] N-Terminal Acetylation of Two Major Latex Proteins from Arabidopsis thaliana Using Electrospray Ionization Tandem Mass Spectrometry
    Wu, Feng-Zhang
    Lu, Tian-Cong
    Shen, Zhuo
    Wang, Bai-Chen
    Wang, Hong-Xia
    PLANT MOLECULAR BIOLOGY REPORTER, 2008, 26 (02) : 88 - 97
  • [3] N-Terminal Acetylation of Two Major Latex Proteins from Arabidopsis thaliana Using Electrospray Ionization Tandem Mass Spectrometry
    Feng-Zhang Wu
    Tian-Cong Lu
    Zhuo Shen
    Bai-Chen Wang
    Hong-Xia Wang
    Plant Molecular Biology Reporter, 2008, 26 : 88 - 97
  • [4] Sensitivity improvement of amino acids by N-terminal diisopropyloxyphosphorylation in electrospray ionization mass spectrometry
    Chen, Y
    Zhang, JC
    Chen, J
    Cao, XY
    Wang, J
    Zhao, YF
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (04) : 469 - 473
  • [5] N-terminal acetylation characterization of tumor protein D52 by nano electrospray tandem mass mass spectrometry
    Wang, HX
    Xia, Q
    Li, P
    He, JT
    Wang, J
    Zhang, XM
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (03) : 321 - 324
  • [6] Top-down N-terminal sequencing of Immunoglobulin subunits with electrospray ionization time of flight mass spectrometry
    Ren, Da
    Pipes, Gary D.
    Hambly, David
    Bondarenko, Pavel V.
    Treuheit, Michael J.
    Gadgil, Himanshu S.
    ANALYTICAL BIOCHEMISTRY, 2009, 384 (01) : 42 - 48
  • [7] Determination of ionization efficiency of glycated and non-glycated peptides from the N-terminal of hemoglobin β-chain by electrospray ionization mass spectrometry
    Nakanishi, T
    Shimizu, A
    JOURNAL OF CHROMATOGRAPHY B, 2000, 746 (01): : 83 - 89
  • [8] Identification of N-terminal acetylation in Hb Raleigh (β1Val→Ac-Ala) by electrospray tandem mass spectrometry
    Rai, DK
    Landin, B
    Griffiths, WJ
    Alvelius, G
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (18) : 1793 - 1796
  • [9] The Study of Protein Conformation in Solution Via Direct Sampling by Desorption Electrospray Ionization Mass Spectrometry
    Miao, Zhixin
    Wu, Shiyong
    Chen, Hao
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2010, 21 (10) : 1730 - 1736
  • [10] Mass spectrometry data confirming tetrameric alpha-synuclein N-terminal acetylation
    Fernandez, Ricardo D.
    Lucas, Heather R.
    DATA IN BRIEF, 2018, 20 : 1686 - 1691