Robot-assisted stereoelectroencephalography in young children: technical challenges and considerations

被引:3
|
作者
Boop, Scott [1 ]
Barkley, Ariana [1 ]
Emerson, Samuel [1 ]
Prolo, Laura M. [2 ]
Goldstein, Hannah [3 ]
Ojemann, Jeffrey G. [1 ,3 ]
Hauptman, Jason S. [1 ,3 ]
机构
[1] Univ Washington, Dept Neurol Surg, Seattle, WA 98195 USA
[2] Stanford Univ, Dept Neurosurg, Stanford, CA 94305 USA
[3] Seattle Childrens Hosp, Dept Neurosurg, 4800 Sand Point Way NE,OA 9-220, Seattle, WA 98105 USA
关键词
Stereoelectroencephalography; Epilepsy surgery; Pediatric Neurosurgery; sEEG; FOCAL CORTICAL DYSPLASIA; PRESURGICAL EVALUATION; EPILEPSY SURGERY; ACCURACY; EEG; NEUROSURGERY; METHODOLOGY;
D O I
10.1007/s00381-021-05384-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Robot-assisted stereoelectroencephalography (sEEG) is frequently employed to localize epileptogenic zones in patients with medically refractory epilepsy (MRE). Its methodology is well described in adults, but less so in children. Given the limited information available on pediatric applications, the objective is to describe the unique technical challenges and considerations of sEEG in the pediatric population. In this report, we describe our institutional experience with the technical aspects of robot-assisted sEEG in an exclusively pediatric epilepsy surgery unit, focusing on pre-, intra-, and post-operative nuances that are particular to the pediatric population. The pediatric population presents several unique challenges in sEEG, including reduced skull thickness relative to adults, incomplete neurologic development, and often special behavioral considerations. Pre-operative selection of putative epileptogenic zones requires careful multidisciplinary decision-making. Intraoperative attention to nuances in positioning, clamp selection, registration, and electrode placement are necessary. Activity considerations and electrode migration and removal are key post-operative considerations. Robot-assisted sEEG is a valuable tool in the armamentarium of techniques to characterize MRE. However, special considerations must be given to the pediatric population to optimize safety and efficacy.
引用
收藏
页码:263 / 267
页数:5
相关论文
共 50 条
  • [1] Robot-assisted stereoelectroencephalography in young children: technical challenges and considerations
    Scott Boop
    Ariana Barkley
    Samuel Emerson
    Laura M. Prolo
    Hannah Goldstein
    Jeffrey G. Ojemann
    Jason S. Hauptman
    Child's Nervous System, 2022, 38 : 263 - 267
  • [2] Robot-assisted stereoelectroencephalography in children
    McGovern, Robert A.
    Knight, Elia Pestana
    Gupta, Ajay
    Moosa, Ahsan N., V
    Wyllie, Elaine
    Bingaman, William E.
    Gonzalez-Martinez, Jorge
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2019, 23 (03) : 288 - 296
  • [3] Rigid Cranial Fixation for Robot-Assisted Stereoelectroencephalography in Toddlers: Technical Considerations
    Alexander, Hepzibha
    Fayed, Islam
    Oluigbo, Chima O.
    OPERATIVE NEUROSURGERY, 2020, 18 (06) : 614 - 620
  • [5] Frameless robot-assisted stereoelectroencephalography in children: technical aspects and comparison with Talairach frame technique
    Abel, Taylor J.
    Osorio, Rene Varela
    Amorim-Leite, Ricardo
    Mathieu, Francois
    Kahane, Philippe
    Minotti, Lorella
    Hoffmann, Dominique
    Chabardes, Stephan
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2018, 22 (01) : 37 - 46
  • [6] Robot-assisted laparoscopic pyeloplasty: Technical considerations and outcomes
    Yanke, Brent V.
    Lallas, Costas D.
    Pagnani, Christopher
    Bagley, Demetrius H.
    JOURNAL OF ENDOUROLOGY, 2008, 22 (06) : 1291 - 1295
  • [7] Pediatric Laparoscopic and Robot-Assisted Laparoscopic Surgery: Technical Considerations
    Tomaszewski, Jeffrey J.
    Casella, Daniel P.
    Turner, Robert M., II
    Casale, Pasquale
    Ost, Michael C.
    JOURNAL OF ENDOUROLOGY, 2012, 26 (06) : 602 - 613
  • [8] Technique, Results, and Complications Related to Robot-Assisted Stereoelectroencephalography
    Gonzalez-Martinez, Jorge
    Bulacio, Juan
    Thompson, Susan
    Gale, John
    Smithason, Saksith
    Najm, Imad
    Bingaman, William
    NEUROSURGERY, 2016, 78 (02) : 169 - 179
  • [9] Frameless robot-assisted stereoelectroencephalography for refractory epilepsy in pediatric patients: accuracy, usefulness, and technical issues
    Santiago Candela-Cantó
    Javier Aparicio
    Jordi Muchart López
    Pilar Baños-Carrasco
    Alia Ramírez-Camacho
    Alejandra Climent
    Mariana Alamar
    Cristina Jou
    Jordi Rumià
    Victoria San Antonio-Arce
    Alexis Arzimanoglou
    Enrique Ferrer
    Acta Neurochirurgica, 2018, 160 : 2489 - 2500
  • [10] Implantation accuracy and operative variables in robot-assisted stereoelectroencephalography
    Lee, Suk Joon
    Lee, Philip S.
    Faraji, Amir H.
    Richardson, R. Mark
    Kokkinos, Vasileios
    JOURNAL OF NEUROSURGERY, 2022, 139 (06) : 1598 - 1603